Javascript must be enabled to continue!
The Glowport – Illuminated vitrectomy trocar cannulas
View through CrossRef
The use of small-gauge trocar cannulas during transconjunctival sutureless pars plana vitrectomy (PPV) facilitates the smooth transition of instruments into the posterior segment and reduces trauma. However, room lighting is routinely dimmed during PPV, thereby making cannula visualization difficult and hence compromising efficient instrument exchange. We report the use of a frugal, fluorescent “glow-in-the-dark” ring placed over vitrectomy cannulas to visualize the cannula entry, thereby providing a smooth and efficient instrument exchange. We 3D-printed phosphorescent rings of optimum inner diameter to comfortably fit around the trocar cannula (The Glowport). Two such rings are fitted into the two trocar cannulas prior to surgery initiation. The cannulas are then passed via sclerostomy as performed in routine PPV. The light from the fiberoptic endo-illuminator is focused over the rings for approximately 5 seconds to activate the photoluminescence. Under mesopic conditions, the fluorescence provides visualization of the cannula entry and helps in the facilitation of smooth entry and exchange of instruments into the globe for performing vitreoretinal surgical procedures, which helps in reducing ocular touch errors as well as surgical time. The Glowport is a frugal device retrofitted onto the trocar cannulas and helps in the smooth entry and exchange of instruments under darkroom conditions, which are required in vitreoretinal surgery.
Ovid Technologies (Wolters Kluwer Health)
Title: The Glowport – Illuminated vitrectomy trocar cannulas
Description:
The use of small-gauge trocar cannulas during transconjunctival sutureless pars plana vitrectomy (PPV) facilitates the smooth transition of instruments into the posterior segment and reduces trauma.
However, room lighting is routinely dimmed during PPV, thereby making cannula visualization difficult and hence compromising efficient instrument exchange.
We report the use of a frugal, fluorescent “glow-in-the-dark” ring placed over vitrectomy cannulas to visualize the cannula entry, thereby providing a smooth and efficient instrument exchange.
We 3D-printed phosphorescent rings of optimum inner diameter to comfortably fit around the trocar cannula (The Glowport).
Two such rings are fitted into the two trocar cannulas prior to surgery initiation.
The cannulas are then passed via sclerostomy as performed in routine PPV.
The light from the fiberoptic endo-illuminator is focused over the rings for approximately 5 seconds to activate the photoluminescence.
Under mesopic conditions, the fluorescence provides visualization of the cannula entry and helps in the facilitation of smooth entry and exchange of instruments into the globe for performing vitreoretinal surgical procedures, which helps in reducing ocular touch errors as well as surgical time.
The Glowport is a frugal device retrofitted onto the trocar cannulas and helps in the smooth entry and exchange of instruments under darkroom conditions, which are required in vitreoretinal surgery.
Related Results
Three-Dimensional Printing of a Transconjunctival Vitrectomy Trocar-Cannula System
Three-Dimensional Printing of a Transconjunctival Vitrectomy Trocar-Cannula System
<b><i>Purpose:</i></b> The aim of this paper was to study the feasibility of manufacturing a customizable trocar-cannula system for vitreoretinal surgery ut...
Timing of vitrectomy for treatment of endophthalmitis after intravitreal anti-VEGF injection: a systematic literature review of case reports and series
Timing of vitrectomy for treatment of endophthalmitis after intravitreal anti-VEGF injection: a systematic literature review of case reports and series
Objective:
To perform a systematic literature review analyzing visual outcomes of immediate, early, and delayed vitrectomy in the treatment of acute endophthalm...
Trocar localisation for robot-assisted vitreoretinal surgery
Trocar localisation for robot-assisted vitreoretinal surgery
Abstract
Purpose
Robot-assisted vitreoretinal surgery provides precise and consistent operations on the back of the eye. To perform this safely, kno...
The Role of Vitrectomy in Threatment of Epimacular Fibrosis
The Role of Vitrectomy in Threatment of Epimacular Fibrosis
Purpose:а comparison of the results of epimacular fibrosis surgical treatment with vitrectomy and without it.Patients and methods. Two groups of patients with epimacular fibrosis ...
Trocar Site Hernia after Laparoscopic Colectomy: A Case Report and Literature Review
Trocar Site Hernia after Laparoscopic Colectomy: A Case Report and Literature Review
Background. Trocar Site Hernia (TSH) is defined as an incisional hernia which occurs after minimally invasive surgery on the trocar incision site.In 2004 Tonouchi classified trocar...
Fluid-air exchange as a secondary treatment for unclosed macular hole after primary vitrectomy: a retrospective cohort study
Fluid-air exchange as a secondary treatment for unclosed macular hole after primary vitrectomy: a retrospective cohort study
AIM: To evaluate whether fluid-air exchange is an effective treatment for unclosed macular hole (MH) after primary vitrectomy.
METHODS: This retrospective study included patients w...
The Almodin–Moron Trocar for Uterine Entry during Fetal Surgery
The Almodin–Moron Trocar for Uterine Entry during Fetal Surgery
<i>Objective: </i>Compare the use of a newly designed and reusable metal trocar for initial uterine entry with the disposable Tulipan–Bruner trocar in creation of a hys...
Transconjunctival sutureless 20G
Transconjunctival sutureless 20G
Abstract Purpose To evaluate a trocar system that allows the use of the regular 20‐gauge vitrectomy instruments for a transconjunctival sutureless surgery for the treatment of vari...

