Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Off-Axis Characterisation of the CERN T10 Beam for low Momentum Proton Measurements with a High Pressure Gas Time Projection Chamber

View through CrossRef
We present studies of proton fluxes in the T10 beamline at CERN. A prototype high pressure gas time projection chamber (TPC) was exposed to the beam of protons and other particles, using the 0.8 GeV/c momentum setting in T10, in order to make cross section measurements of low energy protons in argon. To explore the energy region comparable to hadrons produced by GeV-scale neutrino interactions at oscillation experiments, i.e., near 0.1 GeV of kinetic energy, methods of moderating the T10 beam were employed: the dual technique of moderating the beam with acrylic blocks and measuring scattered protons off the beam axis was used to decrease the kinetic energy of incident protons, as well as change the proton/minimum ionising particle (MIP) composition of the incident flux. Measurements of the beam properties were made using time of flight systems upstream and downstream of the TPC. The kinetic energy of protons reaching the TPC was successfully changed from ∼0.3 GeV without moderator blocks to less than 0.1 GeV with four moderator blocks (40 cm path length). The flux of both protons and MIPs off the beam axis was increased. The ratio of protons to MIPs vary as a function of the off-axis angle allowing for possible optimisation of the detector to select the type of required particles. Simulation informed by the time of flight measurements show that with four moderator blocks placed in the beamline, (5.6 ± 0.1) protons with energies below 0.1 GeV per spill traversed the active TPC region. Measurements of the beam composition and energy are presented.
Title: Off-Axis Characterisation of the CERN T10 Beam for low Momentum Proton Measurements with a High Pressure Gas Time Projection Chamber
Description:
We present studies of proton fluxes in the T10 beamline at CERN.
A prototype high pressure gas time projection chamber (TPC) was exposed to the beam of protons and other particles, using the 0.
8 GeV/c momentum setting in T10, in order to make cross section measurements of low energy protons in argon.
To explore the energy region comparable to hadrons produced by GeV-scale neutrino interactions at oscillation experiments, i.
e.
, near 0.
1 GeV of kinetic energy, methods of moderating the T10 beam were employed: the dual technique of moderating the beam with acrylic blocks and measuring scattered protons off the beam axis was used to decrease the kinetic energy of incident protons, as well as change the proton/minimum ionising particle (MIP) composition of the incident flux.
Measurements of the beam properties were made using time of flight systems upstream and downstream of the TPC.
The kinetic energy of protons reaching the TPC was successfully changed from ∼0.
3 GeV without moderator blocks to less than 0.
1 GeV with four moderator blocks (40 cm path length).
The flux of both protons and MIPs off the beam axis was increased.
The ratio of protons to MIPs vary as a function of the off-axis angle allowing for possible optimisation of the detector to select the type of required particles.
Simulation informed by the time of flight measurements show that with four moderator blocks placed in the beamline, (5.
6 ± 0.
1) protons with energies below 0.
1 GeV per spill traversed the active TPC region.
Measurements of the beam composition and energy are presented.

Related Results

Advancements in optics control at the CERN Proton Synchrotron
Advancements in optics control at the CERN Proton Synchrotron
The CERN Proton Synchrotron (PS), operational since 1959, remains a critical component in CERN's accelerator complex, supporting downstream experiments and serving as an injector f...
Risky Cycles in Stock Price Momentum Strategy Returns
Risky Cycles in Stock Price Momentum Strategy Returns
Price momentum strategies are widely used by Quant money managers. They generate high positive returns on average with little systematic risk measured using standard asset pricing...
MO‐SAM‐BRB‐02: Proton Physics and Technology
MO‐SAM‐BRB‐02: Proton Physics and Technology
The dose localization advantages of proton beams derive primarily from the Bragg peak in the proton stopping distribution. Therefore, the potential clinical gains expected form pro...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Design and early operation of a new-generation internal beam dump for CERN’s Super Proton Synchrotron
Design and early operation of a new-generation internal beam dump for CERN’s Super Proton Synchrotron
The Super Proton Synchrotron (SPS) is the last stage in the injector chain for CERN’s Large Hadron Collider, and it also provides proton and ion beams for several fixed-target expe...
SU‐E‐T‐47: A Monte Carlo Model of a Spot Scanning Proton Beam Based On a Synchrotron Proton Therapy Accelerator
SU‐E‐T‐47: A Monte Carlo Model of a Spot Scanning Proton Beam Based On a Synchrotron Proton Therapy Accelerator
Purpose:To build the model of a spot scanning proton beam for the dose calculation of a synchrotron proton therapy accelerator, which is capable of accelerating protons from 50 up ...
Study on Dosimetry Technology of Absorbed Dose to Water for Proton
Study on Dosimetry Technology of Absorbed Dose to Water for Proton
In proton therapy, precise energy transfer to tissues is crucial for cancer treatment, as accurate dose delivery directly influences tumor control efficiency and minimizes radiatio...
SU‐E‐T‐470: Beam Performance of the Radiance 330 Proton Therapy System
SU‐E‐T‐470: Beam Performance of the Radiance 330 Proton Therapy System
Purpose:The ProTom Radiance 330 proton radiotherapy system is a fully functional, compact proton radiotherapy system that provides advanced proton delivery capabilities. It support...

Back to Top