Pulse oximeter perfusion index as a new predictor of hypotension following subarachnoid block in lower segment Cesarean section: A prospective randomized study
View through CrossRef
Background: Hypotension is a common adverse effect of spinal anesthesia, especially during pregnancy, due to the blockade of pre-ganglionic sympathetic fibers, resulting in reduced peripheral vascular resistance. This study explores the perfusion index (PI) as a potential predictor for hypotension during spinal anesthesia in lower segment Cesarean sections (LSCS).
Aims and Objectives: The aim of the study was to study the correlation between baseline PI and the incidence of hypotension following subarachnoid block in LSCS.
Materials and Methods: This prospective observational study included 90 parturients, divided into two groups based on baseline PI: Group 1 (PI≤3.5) and Group 2 (PI>3.5). Spinal anesthesia was administered with 10 mg of 0.5% hyperbaric bupivacaine at the L3-L4 interspace. The study evaluated the correlation between baseline PI and the degree of hypotension, as well as PI’s predictive capacity for hypotension during Cesarean delivery.
Results: Hypotension occurred in 35.55% of Group 1 and 75.55% of Group 2 (P<0.001). A significant correlation was found between baseline PI>3.5 and both the incidence of hypotension and the total mephentermine dose required (P<0.001). The sensitivity and specificity of PI>3.5 for predicting hypotension were 68% and 72.5%, respectively. The area under the receiver operating characteristic curve for PI as a predictor of hypotension was 0.914.
Conclusion: A higher baseline PI is associated with a higher incidence and severity of hypotension following spinal anesthesia. Baseline PI is a reliable predictor of spinal anesthesia-induced hypotension during Cesarean delivery and could be used for early identification and management of at-risk patients.
Pharmamedix India Publication Pvt Ltd
Title: Pulse oximeter perfusion index as a new predictor of hypotension following subarachnoid block in lower segment Cesarean section: A prospective randomized study
Description:
Background: Hypotension is a common adverse effect of spinal anesthesia, especially during pregnancy, due to the blockade of pre-ganglionic sympathetic fibers, resulting in reduced peripheral vascular resistance.
This study explores the perfusion index (PI) as a potential predictor for hypotension during spinal anesthesia in lower segment Cesarean sections (LSCS).
Aims and Objectives: The aim of the study was to study the correlation between baseline PI and the incidence of hypotension following subarachnoid block in LSCS.
Materials and Methods: This prospective observational study included 90 parturients, divided into two groups based on baseline PI: Group 1 (PI≤3.
5) and Group 2 (PI>3.
5).
Spinal anesthesia was administered with 10 mg of 0.
5% hyperbaric bupivacaine at the L3-L4 interspace.
The study evaluated the correlation between baseline PI and the degree of hypotension, as well as PI’s predictive capacity for hypotension during Cesarean delivery.
Results: Hypotension occurred in 35.
55% of Group 1 and 75.
55% of Group 2 (P<0.
001).
A significant correlation was found between baseline PI>3.
5 and both the incidence of hypotension and the total mephentermine dose required (P<0.
001).
The sensitivity and specificity of PI>3.
5 for predicting hypotension were 68% and 72.
5%, respectively.
The area under the receiver operating characteristic curve for PI as a predictor of hypotension was 0.
914.
Conclusion: A higher baseline PI is associated with a higher incidence and severity of hypotension following spinal anesthesia.
Baseline PI is a reliable predictor of spinal anesthesia-induced hypotension during Cesarean delivery and could be used for early identification and management of at-risk patients.
Related Results
The effect of two dose phenylephrin for preventing hypotension during spinal anesthesia for cesarean delivery
The effect of two dose phenylephrin for preventing hypotension during spinal anesthesia for cesarean delivery
Background: Spinal anesthesia-induced hypotension is one of the most complications which can cause many severe maternal and fetal complications. Therefore, the prevention and treat...
The Use of the Pulse Oximeter in Limb Ischemia: The Pulse Study
The Use of the Pulse Oximeter in Limb Ischemia: The Pulse Study
Purpose: Does a non-invasive pulse oximeter probe accurately indicate limb ischemia with inflation of a tourniquet? How are the pulse waveform, perfusion index and oxygen saturatio...
Effects of nitroglycerin versus labetalol on peripheral perfusion during deliberate hypotension for sinus endoscopic surgery: a randomized, controlled, double-blinded trial
Effects of nitroglycerin versus labetalol on peripheral perfusion during deliberate hypotension for sinus endoscopic surgery: a randomized, controlled, double-blinded trial
Abstract
Background
Deliberate hypotension is used to provide a bloodless field during functional endoscopic sinus surgery; however, the impact of controlled hypotension during ane...
Evaluation of a New Smartphone Powered Low-cost Pulse Oximeter Device
Evaluation of a New Smartphone Powered Low-cost Pulse Oximeter Device
BACKGROUND: Measurement of blood oxygen saturation is a vital part of monitoring coronavirus 2019 (COVID-19) patients. Pulse oximetry is commonly used to measure blood oxygen satur...
USE OF THE PARAMETERS OF THE LAW OF DISTRIBUTION OF THE MEASUREMENT ERRORS OF THE PULSE OXIMETER TO SELECT THE SENSOR SETTINGS
USE OF THE PARAMETERS OF THE LAW OF DISTRIBUTION OF THE MEASUREMENT ERRORS OF THE PULSE OXIMETER TO SELECT THE SENSOR SETTINGS
Context is due to the need to develop a methodology for optimising the parameters of pulse oximeter sensor settings based on the practical determination of the accuracy of heart ra...
Continuous Blood Pressure Monitoring with Hypotension Prediction for Epidural Labor Analgesia Induced Hypotension: A Randomized Controlled Trial
Continuous Blood Pressure Monitoring with Hypotension Prediction for Epidural Labor Analgesia Induced Hypotension: A Randomized Controlled Trial
Introduction: Hypotension following epidural labor analgesia (ELA) is its most common complication, affecting approximately 20% of patients and posing risks to both maternal and fe...
Feasibility of Hypotension Prediction Index-Guided Monitoring for Epidural Labor Analgesia: A Randomized Controlled Trial
Feasibility of Hypotension Prediction Index-Guided Monitoring for Epidural Labor Analgesia: A Randomized Controlled Trial
Background: Hypotension following epidural labor analgesia (ELA) is its most common complication, affecting approximately 20% of patients and posing risks to both maternal and feta...
Predictors of success of trial of labor after cesarean section: A nested case–control study at public hospitals in Eastern Ethiopia
Predictors of success of trial of labor after cesarean section: A nested case–control study at public hospitals in Eastern Ethiopia
Background: One of the primary reasons for an increase in cesarean sections is obstetricians’ uncertainty about labor trial safety following a previous cesarean section. The succes...