Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Development of sustainable concrete bridge deck slab systems using corrosion-resistant GRFP bars

View through CrossRef
This research investigates the use of glass fiber reinforced polymer (GFRP) bars to reinforce the bridge deck slabs as well as jointed precast bridge deck slab in prefabricated bulb-tee pre-tensioned bridge girders. The experimental program included two phases. In phase (I), six precast slab joint details between flanges of precast bulb-tee girders were developed incorporating GFRP bars with straight ends, L-shaped ends and headed ends, embedded in a closure strip filled with non-shrink cement grout or ultra-high-performance concrete (UHPC). A total of 11 actual-size specimens representing the one-way slab system with the proposed joint details, in addition to 5 cast-in-place control specimens, were built and tested to failure to examine the structural adequacy of the proposed joint details. Based on the results from Phase (I), the best joint was selected for further tests in Phase (II) to examine its fatigue life and ultimate load carrying capacity under vehicular wheel loading. A total of 8 actual-size, GFRP-reinforced, 3500 X 2500 X 200 mm concrete deck slabs were designed for this purpose according to CHBDC specifications. Ultimate strength, fatigue behavior and fatigue life of the GFRP-reinforced deck slabs were investigated using different schemes of fatigue loading, namely: accelerated variable amplitude fatigue loading and constant amplitude fatigue loading. Overall, the experimental results indicated that GFRP-reinforced deck slabs showed high fatigue performance. A new prediction model for fatigue life of the GRFP-reinforced deck slabs was developed. The failure mode of the tested composite slabs was punching shear. Correlation between the experimental findings and the prediction models for punching shear resistance available in the literature showed that the prediction models by CSA S806-12 (2012) and El-Gamal et al. (2005) can accurately predict the punching shear capacity of the cast-in-place and precast jointed bridge deck slabs reinforced with GFRP bars. In addition, the average observed mid-depth punching shear perimeter for the cast-in-place deck slabs and the precast jointed deck slabs were measured to be 1.25 d and 1.33d away from the sides of the loaded area, respectively, which are more than twice the corresponding distance specified in ACI 440.1R-06 and CSA S806-12 for calculating the critical punching shear perimeter.
Ryerson University Library and Archives
Title: Development of sustainable concrete bridge deck slab systems using corrosion-resistant GRFP bars
Description:
This research investigates the use of glass fiber reinforced polymer (GFRP) bars to reinforce the bridge deck slabs as well as jointed precast bridge deck slab in prefabricated bulb-tee pre-tensioned bridge girders.
The experimental program included two phases.
In phase (I), six precast slab joint details between flanges of precast bulb-tee girders were developed incorporating GFRP bars with straight ends, L-shaped ends and headed ends, embedded in a closure strip filled with non-shrink cement grout or ultra-high-performance concrete (UHPC).
A total of 11 actual-size specimens representing the one-way slab system with the proposed joint details, in addition to 5 cast-in-place control specimens, were built and tested to failure to examine the structural adequacy of the proposed joint details.
Based on the results from Phase (I), the best joint was selected for further tests in Phase (II) to examine its fatigue life and ultimate load carrying capacity under vehicular wheel loading.
A total of 8 actual-size, GFRP-reinforced, 3500 X 2500 X 200 mm concrete deck slabs were designed for this purpose according to CHBDC specifications.
Ultimate strength, fatigue behavior and fatigue life of the GFRP-reinforced deck slabs were investigated using different schemes of fatigue loading, namely: accelerated variable amplitude fatigue loading and constant amplitude fatigue loading.
Overall, the experimental results indicated that GFRP-reinforced deck slabs showed high fatigue performance.
A new prediction model for fatigue life of the GRFP-reinforced deck slabs was developed.
The failure mode of the tested composite slabs was punching shear.
Correlation between the experimental findings and the prediction models for punching shear resistance available in the literature showed that the prediction models by CSA S806-12 (2012) and El-Gamal et al.
(2005) can accurately predict the punching shear capacity of the cast-in-place and precast jointed bridge deck slabs reinforced with GFRP bars.
In addition, the average observed mid-depth punching shear perimeter for the cast-in-place deck slabs and the precast jointed deck slabs were measured to be 1.
25 d and 1.
33d away from the sides of the loaded area, respectively, which are more than twice the corresponding distance specified in ACI 440.
1R-06 and CSA S806-12 for calculating the critical punching shear perimeter.

Related Results

Development of sustainable concrete bridge deck slab systems using corrosion-resistant GRFP bars
Development of sustainable concrete bridge deck slab systems using corrosion-resistant GRFP bars
This research investigates the use of glass fiber reinforced polymer (GFRP) bars to reinforce the bridge deck slabs as well as jointed precast bridge deck slab in prefabricated bul...
Seismic Response Optimization of RC Slabs: Influence of Opening Location, Size, and Geometry on Structural Performance
Seismic Response Optimization of RC Slabs: Influence of Opening Location, Size, and Geometry on Structural Performance
In this research, the influence of the location, area and shape of the openings on the seismic behavior and performance of the concrete slab roof was evaluated and studied using th...
Snorre TLP Topside Design
Snorre TLP Topside Design
ABSTRACT This paper gives a brief description of the topside facilities and integrated deck structure for the Snorre TLP which will operate on Block 34/7 in the N...
EXPERIMENTAL RESEARCH ON REINFORCED CONCRETE SLABS WITH LOADS FROM COLUMN PLACED ON THE SLAB
EXPERIMENTAL RESEARCH ON REINFORCED CONCRETE SLABS WITH LOADS FROM COLUMN PLACED ON THE SLAB
Slabs made of reinforced concrete often get subjected to loads that are distributed uniformly across the whole surface of the slab. On the other hand, there are situations in which...
Modern trends in the production of corrosion-resistant and fire-resistant stress-free reinforcing bars
Modern trends in the production of corrosion-resistant and fire-resistant stress-free reinforcing bars
The aim of this work is to study modern methods of production of corrosion-resistant and fire-resistant stress-free reinforcing bars in the world. Non-stressed reinforcing bars are...
Failure and Repair of Deck Closure Pour on Interstate 81
Failure and Repair of Deck Closure Pour on Interstate 81
On April 6, 2009, a 3-ft × 3-ft section of a closure pour in a reinforced concrete deck on Interstate 81 punched through. The deck had been cast in 1992 during a deck replacement p...
Structural Aspects Of Snorre Mating
Structural Aspects Of Snorre Mating
ABSTRACT The deck and the hull of the Snorre TLP were successfully connected South of Stord on the Norwegian westcoast in September 1991. The 28.000 tonnes deck w...

Back to Top