Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Clinical accuracy between planned and placed posterior implant position of two static implant planning software programs in inexperienced operators 

View through CrossRef
Objective: This study aimed to evaluate and examine the difference in posterior implant positioning between the planned and placed positions when inexperienced operators used two static implant planning software packages following a fully guided implant surgery protocol in the clinical field. Materials and methods: Twenty-four patients who needed single posterior implant placement were randomly divided into two groups based on the used implant planning software (group 1, coDiagnostiX, n=12; group 2, Implant Studio, n=12). The dataset of the placed implant position, generated from digitizing the implant impression, was superimposed on the planned implant position. The number of horizontal, angular, and vertical deviations of the placed implants were measured for each software package and statistically analyzed. Results: Group 1 (coDiagnostiX) presented with a mean horizontal deviation at the entry point (DE) of 1.07 ± 0.36 mm, mean angular deviation (DA) of 3.52 ± 1.64, and mean depth deviation (DD) of −0.71 ± 0.29 mm, while the mean DE, mean DA, and mean DD in group 2 (Implant Studio) were 0.97 ± 0.33 mm, 3.77 ± 2.16, and −0.84 ± 0.30 mm respectively. Statistically, no significant differences were found between groups 1 and 2 for all results reported above (P>0.05) Conclusions: No significant differences were found in the accuracy of implant position between coDiagnostiX and Implant Studio programs following posterior implant placement performed by inexperienced operators.  
Office of Academic Resources, Chulalongkorn University
Title: Clinical accuracy between planned and placed posterior implant position of two static implant planning software programs in inexperienced operators 
Description:
Objective: This study aimed to evaluate and examine the difference in posterior implant positioning between the planned and placed positions when inexperienced operators used two static implant planning software packages following a fully guided implant surgery protocol in the clinical field.
Materials and methods: Twenty-four patients who needed single posterior implant placement were randomly divided into two groups based on the used implant planning software (group 1, coDiagnostiX, n=12; group 2, Implant Studio, n=12).
The dataset of the placed implant position, generated from digitizing the implant impression, was superimposed on the planned implant position.
The number of horizontal, angular, and vertical deviations of the placed implants were measured for each software package and statistically analyzed.
Results: Group 1 (coDiagnostiX) presented with a mean horizontal deviation at the entry point (DE) of 1.
07 ± 0.
36 mm, mean angular deviation (DA) of 3.
52 ± 1.
64, and mean depth deviation (DD) of −0.
71 ± 0.
29 mm, while the mean DE, mean DA, and mean DD in group 2 (Implant Studio) were 0.
97 ± 0.
33 mm, 3.
77 ± 2.
16, and −0.
84 ± 0.
30 mm respectively.
Statistically, no significant differences were found between groups 1 and 2 for all results reported above (P>0.
05) Conclusions: No significant differences were found in the accuracy of implant position between coDiagnostiX and Implant Studio programs following posterior implant placement performed by inexperienced operators.
 .

Related Results

Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
ABSTRACT Background: Overloading has been identified as a primary factor behind dental implant failure. The peak bone stresses normally appear in the marginal bone. The anchorage s...
Global Software Team and Inexperienced Software Team
Global Software Team and Inexperienced Software Team
Given that the number of qualified programmers cannot be increased drastically and rapidly, software managers in most parts of the world will likely have to live with a human resou...
Soft tissue reconstructive techniques at implant sites
Soft tissue reconstructive techniques at implant sites
Dental implants have shown to be a reliable tool for single, multiple and full-arch rehabilitations 1. Dental implants have a very high success rate in terms of osseointegration, h...
Influence of Roxolid Implant Material on The Implant Stability of Maxillary Implant Retained Overdenture
Influence of Roxolid Implant Material on The Implant Stability of Maxillary Implant Retained Overdenture
Abstract Background Long-term success of implant restoration depends on many factors one of them is the sufficient implant stability which is lowered in compromised bone d...
Soft tissue features of peri‐implant diseases and related treatment
Soft tissue features of peri‐implant diseases and related treatment
AbstractBackgroundThe need for soft tissue grafting at implant sites for preventing and treating peri‐implant diseases is a currently investigated and debated topic.PurposeThe aim ...
Evaluation of hybrid implant in posterior edentulous maxilla with inadequate bone
Evaluation of hybrid implant in posterior edentulous maxilla with inadequate bone
Aim of this study is to investigate.Hybrid implant has got satisfactory results in our previous study in various edentulous areas with inadequate bone for endosseous implant placem...

Back to Top