Energy Optimization for Fenestration Design: Evidence-Based Retrofitting Solution for Office Buildings in the UAE
View through CrossRef
With the prevalent use of large glazings, particularly in office buildings, offices receive an abundance of light and are among the largest consumers of electricity. Moreover, in an extreme hot arid climate such as in the UAE, achieving comfortable daylighting levels without increasing solar heat gain is a challenge, in which the window or fenestration design plays an essential role. This research adopts a case study of a higher education (HE) office building on the United Arab Emirates University (UAEU) campus, selected to investigate an evidence-based retrofitting solution for the west façade that can be applied in existing office buildings in the UAE in order to reduce cooling energy load as well as enhance indoor environmental quality. To achieve an evidence-based retrofitting solution, the research design built upon a comprehensive exploratory investigation that included indoor environmental quality physical monitoring and occupant satisfaction surveying. Model simulation was performed by means of DesignBuilder software to perform a single- and multiparameter sensitivity analysis for three key passive window design parameters, i.e., window-to-wall ratio, glazing type, and external shading, aimed towards minimizing annual cooling load and solar heat gain, while maintaining appropriate indoor daylight illuminance levels. The results highlight the importance of the window-to-wall ratio (WWR), as it is the single most significant parameter effecting total energy consumption and daylighting levels. The results recommend 20–30% WWR as the optimum range in the west façade. However, by utilizing high performance glazing types and external shading, equal energy savings can be achieved with a larger WWR. Double Low E tinted glazing and 0.4 projection shading overhang and side fin revealed a noteworthy reduction of energy use intensity of 14%. The study concludes with final retrofitting solutions and design recommendations that aim to contribute validated knowledge towards enhancing window performance in a hot arid climate to guide architects and stakeholders to apply a range of passive parameters towards reducing energy consumption and improving occupant comfort in office buildings.
Title: Energy Optimization for Fenestration Design: Evidence-Based Retrofitting Solution for Office Buildings in the UAE
Description:
With the prevalent use of large glazings, particularly in office buildings, offices receive an abundance of light and are among the largest consumers of electricity.
Moreover, in an extreme hot arid climate such as in the UAE, achieving comfortable daylighting levels without increasing solar heat gain is a challenge, in which the window or fenestration design plays an essential role.
This research adopts a case study of a higher education (HE) office building on the United Arab Emirates University (UAEU) campus, selected to investigate an evidence-based retrofitting solution for the west façade that can be applied in existing office buildings in the UAE in order to reduce cooling energy load as well as enhance indoor environmental quality.
To achieve an evidence-based retrofitting solution, the research design built upon a comprehensive exploratory investigation that included indoor environmental quality physical monitoring and occupant satisfaction surveying.
Model simulation was performed by means of DesignBuilder software to perform a single- and multiparameter sensitivity analysis for three key passive window design parameters, i.
e.
, window-to-wall ratio, glazing type, and external shading, aimed towards minimizing annual cooling load and solar heat gain, while maintaining appropriate indoor daylight illuminance levels.
The results highlight the importance of the window-to-wall ratio (WWR), as it is the single most significant parameter effecting total energy consumption and daylighting levels.
The results recommend 20–30% WWR as the optimum range in the west façade.
However, by utilizing high performance glazing types and external shading, equal energy savings can be achieved with a larger WWR.
Double Low E tinted glazing and 0.
4 projection shading overhang and side fin revealed a noteworthy reduction of energy use intensity of 14%.
The study concludes with final retrofitting solutions and design recommendations that aim to contribute validated knowledge towards enhancing window performance in a hot arid climate to guide architects and stakeholders to apply a range of passive parameters towards reducing energy consumption and improving occupant comfort in office buildings.
Related Results
Assessing energy rating premiums in the performance of green office buildings in Australia
Assessing energy rating premiums in the performance of green office buildings in Australia
Purpose– Green office buildings have recently taken on increased significance in institutional property portfolios in Australia and globally. The key issue from an institutional in...
Drilling Into Diversity: Developing the Reservoir of Talent
Drilling Into Diversity: Developing the Reservoir of Talent
Abstract
In the last few years, opportunities for women in the United Arab Emirates (UAE) have grown exponentially with professional and educational positions openin...
Deep Retrofitting Study of Government Buildings in the UAE
Deep Retrofitting Study of Government Buildings in the UAE
This report summarizes the findings of a deep retrofitting modelling study of four government buildings across the UAE. Buildings envelope assessment, HVAC, and electrical systems ...
From Foes to Friends: The Normalization of the United Emirates Arab and Israel Relations
From Foes to Friends: The Normalization of the United Emirates Arab and Israel Relations
Abstract
This article aims to explain the reason the United Arab Emirates (UAE) normalized ties within Israel through Abraham Accord. The normalization of the UAE-Isr...
Sustainable Retrofitting of Existing Buildings: Techniques and Case Studies
Sustainable Retrofitting of Existing Buildings: Techniques and Case Studies
Retrofitting existing buildings for sustainability has become a critical endeavor in the quest for more energy-efficient and environmentally friendly built environments. This abstr...
Retrofitting an Existing Office Building in the UAE Towards Achieving Low-Energy Building
Retrofitting an Existing Office Building in the UAE Towards Achieving Low-Energy Building
Retrofitting an existing building can oftentimes be more cost-effective than building a new facility. Since buildings consume a significant amount of energy, particularly for heati...
Fenestration Condensation Resistance: Computer Simulation and In Situ Performance
Fenestration Condensation Resistance: Computer Simulation and In Situ Performance
Abstract
The purpose of this paper is to examine condensation rating procedures, specifically the procedures as defined by the National Fenestration Rating Council (...
Transprosthetic Fenestration With Electrified Wires. Experimental Evaluation of Three Multifilament Endografts
Transprosthetic Fenestration With Electrified Wires. Experimental Evaluation of Three Multifilament Endografts
Purpose: In situ fenestration of aortic endografts is an alternative endovascular technique for treatment of complex aortic aneurysms. While this technique has been carried out als...