Javascript must be enabled to continue!
Fenestration Condensation Resistance: Computer Simulation and In Situ Performance
View through CrossRef
Abstract
The purpose of this paper is to examine condensation rating procedures, specifically the procedures as defined by the National Fenestration Rating Council (NFRC), and to compare the standardized procedure with in situ performance data. The American Architectural Manufacturers Association (AAMA) was the first to develop standardized methods to compare fenestration system performance with respect to the formation of condensation. Following this, the NFRC developed its own procedure for developing condensation resistance values. The AAMA test method involves laboratory testing, while the NFRC method involves computer simulation. Both methods provide a rating system to enable relative ease in performance comparison between similar fenestration products. The ratings are based on standardized conditions (i.e., fenestration size and shape, fenestration surround, and environmental conditions) that do not account for the in situ conditions and therefore may not accurately predict actual performance. Recent literature has discussed the limitations of condensation resistance ratings relative to as-built conditions that can impact the formation of condensation on a fenestration system. For example, (1) installing spandrel panel insulation, although necessary to improve the thermal performance of a curtain wall, can lower surface temperatures of adjacent framing members; (2) existing interior blinds or drapery act as an insulator, which can cause the framing members to be colder; and (3) if the fenestration’s thermal break is not aligned with the wall’s insulation, the framing members can be subject to colder temperatures. This paper will focus on the NFRC rating procedure and examine a case study to demonstrate the differences between NFRC ratings, simulated surface temperatures using THERM and WINDOW computer software, and in situ measurements of a high-rise office building curtain wall. The case study will provide a representative illustration of how actual conditions can impact the fenestration product’s in situ condensation resistance and provide insight on the condensation resistance of a representative curtain wall system.
Title: Fenestration Condensation Resistance: Computer Simulation and In Situ Performance
Description:
Abstract
The purpose of this paper is to examine condensation rating procedures, specifically the procedures as defined by the National Fenestration Rating Council (NFRC), and to compare the standardized procedure with in situ performance data.
The American Architectural Manufacturers Association (AAMA) was the first to develop standardized methods to compare fenestration system performance with respect to the formation of condensation.
Following this, the NFRC developed its own procedure for developing condensation resistance values.
The AAMA test method involves laboratory testing, while the NFRC method involves computer simulation.
Both methods provide a rating system to enable relative ease in performance comparison between similar fenestration products.
The ratings are based on standardized conditions (i.
e.
, fenestration size and shape, fenestration surround, and environmental conditions) that do not account for the in situ conditions and therefore may not accurately predict actual performance.
Recent literature has discussed the limitations of condensation resistance ratings relative to as-built conditions that can impact the formation of condensation on a fenestration system.
For example, (1) installing spandrel panel insulation, although necessary to improve the thermal performance of a curtain wall, can lower surface temperatures of adjacent framing members; (2) existing interior blinds or drapery act as an insulator, which can cause the framing members to be colder; and (3) if the fenestration’s thermal break is not aligned with the wall’s insulation, the framing members can be subject to colder temperatures.
This paper will focus on the NFRC rating procedure and examine a case study to demonstrate the differences between NFRC ratings, simulated surface temperatures using THERM and WINDOW computer software, and in situ measurements of a high-rise office building curtain wall.
The case study will provide a representative illustration of how actual conditions can impact the fenestration product’s in situ condensation resistance and provide insight on the condensation resistance of a representative curtain wall system.
Related Results
Comparison of supra-arch in situ fenestration and chimney techniques for aortic dissection involving the left subclavian artery
Comparison of supra-arch in situ fenestration and chimney techniques for aortic dissection involving the left subclavian artery
Introduction Endovascular intervention involving the aortic arch, particularly in thoracic aortic dissection, remains challenging and controversial at current time when there is no...
Transprosthetic Fenestration With Electrified Wires. Experimental Evaluation of Three Multifilament Endografts
Transprosthetic Fenestration With Electrified Wires. Experimental Evaluation of Three Multifilament Endografts
Purpose: In situ fenestration of aortic endografts is an alternative endovascular technique for treatment of complex aortic aneurysms. While this technique has been carried out als...
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract
Introduction
Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
Prediction of Condensation in the Heat Exchangers of Engine Intake Systems according to External Environmental and Operating Conditions
Prediction of Condensation in the Heat Exchangers of Engine Intake Systems according to External Environmental and Operating Conditions
Low-pressure exhaust gas recirculation (LP-EGR) systems are applied to diesel engines because they reduce nitrogen oxide emission by lowering the internal temperature of the cylind...
Long-Term Experimental Evaluation of In Situ Laser-Fenestrated Versus Custom-Made Fenestrated Endografts
Long-Term Experimental Evaluation of In Situ Laser-Fenestrated Versus Custom-Made Fenestrated Endografts
Objective:
This study evaluates the biomechanical performance and long-term durability of in situ laser fenestration (ISLF) compared to custom-made fenestrated ...
Struktur Komunitas Makrozoobentos di Situ Gintung, Situ Bungur Dan Situ Kuru, Ciputat Timur
Struktur Komunitas Makrozoobentos di Situ Gintung, Situ Bungur Dan Situ Kuru, Ciputat Timur
Makrozoobentos adalah biota yang hidup di dalam substrat maupun menempel di permukaan dasar perairan. Makrozoobentos memiliki peran penting dalam eksositem akuatik, yaitu sebagai s...
Effectiveness of Fenestration and Discectomy among Patients Presenting with Lumbar Disc Herniation
Effectiveness of Fenestration and Discectomy among Patients Presenting with Lumbar Disc Herniation
Background:Research-StackExchange47, BackgroundLumbar disc herniation (LDH) is a frequent cause of back pain and neurological dysfunction that often requires surgical treatment. Th...
REVIT SIMULATION APPLICATION IN EVALUATING FENESTRATION STRATEGIES TOWARDS ENERGY CONSERVATION IN MALAYSIAN INTERMEDIATE TERRACED HOUSES
REVIT SIMULATION APPLICATION IN EVALUATING FENESTRATION STRATEGIES TOWARDS ENERGY CONSERVATION IN MALAYSIAN INTERMEDIATE TERRACED HOUSES
With Malaysia’s population rising and rapid urbanisation, terraced houses were built to respond to new social and economic needs. The modern terraced house appeals to the demand f...