Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Field Calibration of Orifice Meters for Natural Gas Flow

View through CrossRef
This paper presents the orifice calibration results for nominal 15.24, 10.16, and 5.08-cm (6, 4, 2-in.) orifice meters conducted at the Chevron’s Sand Hills natural gas flow measurement facility in Crane, Texas. Over 200 test runs were collected in a field environment to study the accuracy of the orifice meters. Data were obtained at beta ratios ranging from 0.12 to 0.74 at the nominal conditions of 4576 kPa and 27°C (650 psig and 80°F) with a 0.57 specific gravity processed, pipeline quality natural gas. A bank of critical flow nozzles was used as the flow rate proving device to calibrate the orifice meters. Orifice discharge coefficients were computed with ANSI/API 2530-1985 (AGA3) and ISO 5167/ASME MFC-3M-1984 equations for every set of data points. The uncertainty of the calibration system was analyzed according to The American National Standard (ANSI/ASME MFC-2M-A1983). The 10.16 and 5.08-cm (4 and 2-in.) orifice discharge coefficients agreed with the ANSI and ISO standards within the estimated uncertainty level. However, the 15.24-cm (6-in.) meter deviated up to − 2 percent at a beta ratio of 0.74. With the orifice bore Reynolds numbers ranging from 1 to 9 million, the Sand Hills calibration data bridge the gap between the Ohio State water data at low Reynolds numbers and Chevron’s high Reynolds number test data taken at a larger test facility in Venice, Louisiana. The test results also successfully demonstrated that orifice meters can be accurately proved with critical flow nozzles under realistic field conditions.
Title: Field Calibration of Orifice Meters for Natural Gas Flow
Description:
This paper presents the orifice calibration results for nominal 15.
24, 10.
16, and 5.
08-cm (6, 4, 2-in.
) orifice meters conducted at the Chevron’s Sand Hills natural gas flow measurement facility in Crane, Texas.
Over 200 test runs were collected in a field environment to study the accuracy of the orifice meters.
Data were obtained at beta ratios ranging from 0.
12 to 0.
74 at the nominal conditions of 4576 kPa and 27°C (650 psig and 80°F) with a 0.
57 specific gravity processed, pipeline quality natural gas.
A bank of critical flow nozzles was used as the flow rate proving device to calibrate the orifice meters.
Orifice discharge coefficients were computed with ANSI/API 2530-1985 (AGA3) and ISO 5167/ASME MFC-3M-1984 equations for every set of data points.
The uncertainty of the calibration system was analyzed according to The American National Standard (ANSI/ASME MFC-2M-A1983).
The 10.
16 and 5.
08-cm (4 and 2-in.
) orifice discharge coefficients agreed with the ANSI and ISO standards within the estimated uncertainty level.
However, the 15.
24-cm (6-in.
) meter deviated up to − 2 percent at a beta ratio of 0.
74.
With the orifice bore Reynolds numbers ranging from 1 to 9 million, the Sand Hills calibration data bridge the gap between the Ohio State water data at low Reynolds numbers and Chevron’s high Reynolds number test data taken at a larger test facility in Venice, Louisiana.
The test results also successfully demonstrated that orifice meters can be accurately proved with critical flow nozzles under realistic field conditions.

Related Results

(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
Wet Gas Measurement with Slotted Orifice Meter--Effect of Geometry of Slots and Pressure
Wet Gas Measurement with Slotted Orifice Meter--Effect of Geometry of Slots and Pressure
Wet gas metering by differential pressure flow meters is gaining prominence in the oil and gas industry, owing to their simple construction. Slotted orifice, a modified version of ...
Efficient and Effective Gas Sensor Calibration with Randomized Gas Mixtures
Efficient and Effective Gas Sensor Calibration with Randomized Gas Mixtures
Introduction The selective quantification of target gases in complex mixtures is an important part of numerous applications of chemical gas sensors. ...
Pengaruh Variasi Tebal Orifice dan Bilangan Reynolds (Re) terhadap Penurunan Tekanan (Pressure Drop) pada Entrance Region
Pengaruh Variasi Tebal Orifice dan Bilangan Reynolds (Re) terhadap Penurunan Tekanan (Pressure Drop) pada Entrance Region
Orifice is a device that is placed in a pipe flow to inhibit the flow of fluid and cause a pressure drop. The measurement of the flow rate (flow rate) is obtained from the differen...
Evaluation of a Close Coupled Slotted Orifice, Electric Impedance, and Swirl Flow Meters for Multiphase Flow
Evaluation of a Close Coupled Slotted Orifice, Electric Impedance, and Swirl Flow Meters for Multiphase Flow
The feasibility of a multiphase flow meter utilizing closely coupled slotted orifice and swirl flow meters along with an impedance sensor is investigated. The slotted flow meter ha...
Multiphase Flow Metering:An Evaluation of Discharge Coefficients
Multiphase Flow Metering:An Evaluation of Discharge Coefficients
Abstract The orifice discharge coefficient (CD) is the constant required to correct theoretical flow rate to actual flow rate. It is known that single phase orifi...
Manager Of Supply Planning And Projects
Manager Of Supply Planning And Projects
Abstract The Southern California Gas Company is responsible for providing gas service to 12 million southern Californians. SoCal Gas, like other major gas distrib...
PR-015-11702-R01 Evaluation of Enhanced Diagnostics for Orifice Meters
PR-015-11702-R01 Evaluation of Enhanced Diagnostics for Orifice Meters
A large installed base of orifice meters, many installed where newer technology meters are impractical, accounts for a significant fraction of the measured volume of natural gas in...

Back to Top