Evaluation of a Close Coupled Slotted Orifice, Electric Impedance, and Swirl Flow Meters for Multiphase Flow

View through CrossRef
The feasibility of a multiphase flow meter utilizing closely coupled slotted orifice and swirl flow meters along with an impedance sensor is investigated. The slotted flow meter has been shown to exhibit well behaved response curves to two phase flow mixtures with the pressure difference monotonically increasing with mixture density and flow rate. It has been determined to have less than 1% uncertainty in determining the flow rate if the density of the fluid is known. Flow visualizations have shown that the slotted orifice is a very good mixing device as well producing a homogenous mixture for several pipe diameters downstream of the plate. This characteristic is utilized to provide a homogeneous mixture at the inlet to the swirl meter. This is possible since the slotted orifice is relatively insensitive to upstream and downstream flow disturbances. The swirl meter has been shown to indicate decreased flow rate as the mixture density increases which is opposite to the slotted orifice making the solution of the two meter outputs to obtain density and flow rate feasible. Additional instrumentation is included. Between the slotted orifice and swirl meter where the flow is homogenous a custom manufactured electrical impedance sensor is installed and monitored. This array of instrumentation will provide three independent measurements which are evaluated to determine which system of equations are robust enough to provide accurate density and flow rate measurement over a wide range of gas volume fractions using a very compact system.
Title: Evaluation of a Close Coupled Slotted Orifice, Electric Impedance, and Swirl Flow Meters for Multiphase Flow
Description:
The feasibility of a multiphase flow meter utilizing closely coupled slotted orifice and swirl flow meters along with an impedance sensor is investigated.
The slotted flow meter has been shown to exhibit well behaved response curves to two phase flow mixtures with the pressure difference monotonically increasing with mixture density and flow rate.
It has been determined to have less than 1% uncertainty in determining the flow rate if the density of the fluid is known.
Flow visualizations have shown that the slotted orifice is a very good mixing device as well producing a homogenous mixture for several pipe diameters downstream of the plate.
This characteristic is utilized to provide a homogeneous mixture at the inlet to the swirl meter.
This is possible since the slotted orifice is relatively insensitive to upstream and downstream flow disturbances.
The swirl meter has been shown to indicate decreased flow rate as the mixture density increases which is opposite to the slotted orifice making the solution of the two meter outputs to obtain density and flow rate feasible.
Additional instrumentation is included.
Between the slotted orifice and swirl meter where the flow is homogenous a custom manufactured electrical impedance sensor is installed and monitored.
This array of instrumentation will provide three independent measurements which are evaluated to determine which system of equations are robust enough to provide accurate density and flow rate measurement over a wide range of gas volume fractions using a very compact system.

Related Results

Rotordynamic Performance of a Negative-Swirl Brake for a Tooth-on-Stator Labyrinth Seal
Rotordynamic Performance of a Negative-Swirl Brake for a Tooth-on-Stator Labyrinth Seal
In the late 1970’s, Benckert and Wachter (Technical University Stuttgart) tested labyrinth seals using air as the test media and measured direct and cross-coupled stiffness coeffic...
Wet Gas Measurement with Slotted Orifice Meter--Effect of Geometry of Slots and Pressure
Wet Gas Measurement with Slotted Orifice Meter--Effect of Geometry of Slots and Pressure
Wet gas metering by differential pressure flow meters is gaining prominence in the oil and gas industry, owing to their simple construction. Slotted orifice, a modified version of ...
Multiphase Flow Metering:An Evaluation of Discharge Coefficients
Multiphase Flow Metering:An Evaluation of Discharge Coefficients
Abstract The orifice discharge coefficient (CD) is the constant required to correct theoretical flow rate to actual flow rate. It is known that single phase orifi...
Implementation of multiphase metering on unmanned wellhead platform
Implementation of multiphase metering on unmanned wellhead platform
Abstract In 1997 TotalFinaElf installed a multiphase meter on an offshore unmanned wellhead platform in the Middle East. The decision to go for the multiphase met...
MMS 1200: Cooperation on a Subsea Multiphase Flow Meter Application
MMS 1200: Cooperation on a Subsea Multiphase Flow Meter Application
Abstract PETROBRAS (Brazil) and FLIJENTA (Norway and USA) are since beginning of 1996 working on this multiphase flow metering route development under a Technolog...
Multiphase Flow Measurement Using Multiple Energy Gamma Ray Absorption (MEGRA) Composition Measurement
Multiphase Flow Measurement Using Multiple Energy Gamma Ray Absorption (MEGRA) Composition Measurement
Abstract Some multiphase flowmeters use the principle of Dual Energy Gamma Ray Absorption (DEGRA) composition measurement to determine the individual water, oil a...