Javascript must be enabled to continue!
PR-015-11702-R01 Evaluation of Enhanced Diagnostics for Orifice Meters
View through CrossRef
A large installed base of orifice meters, many installed where newer technology meters are impractical, accounts for a significant fraction of the measured volume of natural gas in the United States. Ultrasonic meters are newer technology meters that provide integrated diagnostics to monitor the meters health and identify flow problems such as distorted velocity profiles and other operational issues. The need exists for similar diagnostics for orifice meters to identify operational causes of measurement errors (and possibly measure their magnitudes), allow users to perform orifice meter maintenance as needed, reduce maintenance costs, and reduce the fiscal impact of significant measurement errors. Research was conducted to identify and recommend candidate technologies for development into practical, cost-effective orifice meter diagnostic tools..
Title: PR-015-11702-R01 Evaluation of Enhanced Diagnostics for Orifice Meters
Description:
A large installed base of orifice meters, many installed where newer technology meters are impractical, accounts for a significant fraction of the measured volume of natural gas in the United States.
Ultrasonic meters are newer technology meters that provide integrated diagnostics to monitor the meters health and identify flow problems such as distorted velocity profiles and other operational issues.
The need exists for similar diagnostics for orifice meters to identify operational causes of measurement errors (and possibly measure their magnitudes), allow users to perform orifice meter maintenance as needed, reduce maintenance costs, and reduce the fiscal impact of significant measurement errors.
Research was conducted to identify and recommend candidate technologies for development into practical, cost-effective orifice meter diagnostic tools.
Related Results
Wet Gas Measurement with Slotted Orifice Meter--Effect of Geometry of Slots and Pressure
Wet Gas Measurement with Slotted Orifice Meter--Effect of Geometry of Slots and Pressure
Wet gas metering by differential pressure flow meters is gaining prominence in the oil and gas industry, owing to their simple construction. Slotted orifice, a modified version of ...
Field Calibration of Orifice Meters for Natural Gas Flow
Field Calibration of Orifice Meters for Natural Gas Flow
This paper presents the orifice calibration results for nominal 15.24, 10.16, and 5.08-cm (6, 4, 2-in.) orifice meters conducted at the Chevron’s Sand Hills natural gas flow measur...
Pengaruh Variasi Tebal Orifice dan Bilangan Reynolds (Re) terhadap Penurunan Tekanan (Pressure Drop) pada Entrance Region
Pengaruh Variasi Tebal Orifice dan Bilangan Reynolds (Re) terhadap Penurunan Tekanan (Pressure Drop) pada Entrance Region
Orifice is a device that is placed in a pipe flow to inhibit the flow of fluid and cause a pressure drop. The measurement of the flow rate (flow rate) is obtained from the differen...
Abstract Or101: Evaluating the National Institutes of Health Pipeline for Resuscitation Science Investigators
Abstract Or101: Evaluating the National Institutes of Health Pipeline for Resuscitation Science Investigators
Background:
The pipeline of investigators studying resuscitation science and their contributions to the field after attaining research independence are largely unknown....
PR-015-06601-R01 Evaluation of Clamp-on Ultrasonic Meters as Field-Portable Diagnostic Tool
PR-015-06601-R01 Evaluation of Clamp-on Ultrasonic Meters as Field-Portable Diagnostic Tool
This study has continued work begun in 2005 to evaluate the use of commercially-available clamp-on ultrasonic meters (USMs) in diagnosing natural gas flow conditions that can produ...
A cone-beam computed tomographic study of root canal systems in mandibular premolars in a Turkish population: Theoretical model for determining orifice shape
A cone-beam computed tomographic study of root canal systems in mandibular premolars in a Turkish population: Theoretical model for determining orifice shape
ABSTRACT
Objective: The purposes of this retrospective study were to represent a newly designed theoretical model for determining orifice shape and morphologic properties...
PR-015-09605-R01 Extended Low Flow Range Metering
PR-015-09605-R01 Extended Low Flow Range Metering
Natural gas meters are often used to measure flows below their minimum design flow rate. This can occur because of inaccurate flow projections, widely varying flow rates in the lin...
Meta-analysis of the predictive value of ultrasonic measurement of cervical internal orifice width and cervical length for premature delivery
Meta-analysis of the predictive value of ultrasonic measurement of cervical internal orifice width and cervical length for premature delivery
Objective: To systematically assess the predictive value of ultrasonic measurement of cervical internal orifice width andcervical length for premature delivery.Method: The systemat...