PR-015-09605-R01 Extended Low Flow Range Metering

View through CrossRef
Natural gas meters are often used to measure flows below their minimum design flow rate. This can occur because of inaccurate flow projections, widely varying flow rates in the line, a lack of personnel available to change orifice plates, and other causes. The use of meters outside their design ranges can result in significant measurement errors. The objectives of this project were to examine parameters that contribute to measurement error at flow rates below 10% of a meters capacity, determine the expected range of error at these flow rates, and establish methods to reduce measurement error in this range. The project began with a literature search of prior studies of orifice, turbine, and ultrasonic meters for background information on their performance in low flows. Two conditions affecting multiple meter types were identified for study. First, temperature measurement errors in low flows can influence the accuracy of all three meter types, though the effect of a given temperature error can differ among the meter types. Second, thermally stratified flows at low flow rates are known to cause measurement errors in ultrasonic meters that cannot compensate for the resulting flow profiles, and the literature suggested that these flows could also affect orifice plates and turbine meters. Several possible ways to improve temperature measurements in low flows were also identified for further study. Next, an analytical study focused on potential errors due to inaccurate temperature measurements. Numerical tools were used to model a pipeline with different thermowell and RTD geometries. The goals were to estimate temperature measurement errors under different low-flow conditions, and to identify approaches to minimize temperature and flow rate errors. Thermal conduction from the pipe wall to the thermowell caused the largest predicted bias in measured temperature, while stratified temperatures in the flow caused relatively little temperature bias. Thermally isolating the thermowell from the pipe wall, or using a bare RTD, can minimize temperature bias, but are not usually practical approaches. Insulation of the meter run and the use of a finned thermowell design were practical methods predicted to potentially improve measurement accuracy, and were chosen for testing.
Pipeline Research Council International, Inc. (PRCI)
Title: PR-015-09605-R01 Extended Low Flow Range Metering
Description:
Natural gas meters are often used to measure flows below their minimum design flow rate.
This can occur because of inaccurate flow projections, widely varying flow rates in the line, a lack of personnel available to change orifice plates, and other causes.
The use of meters outside their design ranges can result in significant measurement errors.
The objectives of this project were to examine parameters that contribute to measurement error at flow rates below 10% of a meters capacity, determine the expected range of error at these flow rates, and establish methods to reduce measurement error in this range.
The project began with a literature search of prior studies of orifice, turbine, and ultrasonic meters for background information on their performance in low flows.
Two conditions affecting multiple meter types were identified for study.
First, temperature measurement errors in low flows can influence the accuracy of all three meter types, though the effect of a given temperature error can differ among the meter types.
Second, thermally stratified flows at low flow rates are known to cause measurement errors in ultrasonic meters that cannot compensate for the resulting flow profiles, and the literature suggested that these flows could also affect orifice plates and turbine meters.
Several possible ways to improve temperature measurements in low flows were also identified for further study.
Next, an analytical study focused on potential errors due to inaccurate temperature measurements.
Numerical tools were used to model a pipeline with different thermowell and RTD geometries.
The goals were to estimate temperature measurement errors under different low-flow conditions, and to identify approaches to minimize temperature and flow rate errors.
Thermal conduction from the pipe wall to the thermowell caused the largest predicted bias in measured temperature, while stratified temperatures in the flow caused relatively little temperature bias.
Thermally isolating the thermowell from the pipe wall, or using a bare RTD, can minimize temperature bias, but are not usually practical approaches.
Insulation of the meter run and the use of a finned thermowell design were practical methods predicted to potentially improve measurement accuracy, and were chosen for testing.

Related Results

Design and simulation for seeding performance of high-speed inclined corn metering device based on discrete element method (DEM)
Design and simulation for seeding performance of high-speed inclined corn metering device based on discrete element method (DEM)
AbstractMechanical precision corn seed-metering planter has a compact structure, missed and repeated seeding advantages during high-speed operation. In this regard, the current res...
A technical and financial analysis of smart prepaid split meters on Eskom's electric power distribution
A technical and financial analysis of smart prepaid split meters on Eskom's electric power distribution
The implementation of a smart metering system in the distribution network does not only promote energy loss reduction, but also improves smart grids. This improvement in smart grid...
Abstract Or101: Evaluating the National Institutes of Health Pipeline for Resuscitation Science Investigators
Abstract Or101: Evaluating the National Institutes of Health Pipeline for Resuscitation Science Investigators
Background: The pipeline of investigators studying resuscitation science and their contributions to the field after attaining research independence are largely unknown....
Method for identifying a connection with a metering defect among multiple connections on a single busbar section
Method for identifying a connection with a metering defect among multiple connections on a single busbar section
Purpose. The purpose of this work is to develop a methodology for identifying a defective connection on a single medium- or low-voltage busbar section among several parallel connec...
Research on adaptive state prediction method for the metering error of capacitor voltage transformer
Research on adaptive state prediction method for the metering error of capacitor voltage transformer
A capacitor voltage transformer (CVT) is widely used in high voltage power systems because of its good insulation performance. However, the structure of CVT is more complex and the...
Multiphase Flow Metering:An Evaluation of Discharge Coefficients
Multiphase Flow Metering:An Evaluation of Discharge Coefficients
Abstract The orifice discharge coefficient (CD) is the constant required to correct theoretical flow rate to actual flow rate. It is known that single phase orifi...
KOC's Effort Towards Better Fiscal Metering
KOC's Effort Towards Better Fiscal Metering
Abstract As part of the continual improvement and expansion of Kuwait Oil Company’s (KOC) infrastructure, the company is currently executing mega fuel gas and liquid...
Evaluation of Machine Learning Methods for Prediction of Multiphase Production Rates
Evaluation of Machine Learning Methods for Prediction of Multiphase Production Rates
Abstract Multiphase flow metering is an important tool for production monitoring and optimization. Although there are many technologies available on the market, the ...

Back to Top