Method for identifying a connection with a metering defect among multiple connections on a single busbar section

View through CrossRef
Purpose. The purpose of this work is to develop a methodology for identifying a defective connection on a single medium- or low-voltage busbar section among several parallel connections. Methodology. As is known, from three to two dozen connections can be powered simultaneously from the busbar section of the main step-down substation with a higher voltage of 35÷154 kV, a dead-end substation with a medium voltage of 10 (6) kV or a transformer substation with a voltage of 10 (6)/0.4 kV.A metering device defect on one of these connections can only be detected using the balance method (where a metering device, usually for commercial purposes, is installed at the busbar section input, and each outgoing connection from the busbar section is also equipped with an electricity meter). The search for a defective metering device is carried out by inspecting all metering devices for each connection. Among them, the defective device is identified. However, this procedure often takes a significant amount of time, requires the implementation of organizational and technical measures when working in operational electrical installations, and can lead to emergency disconnections of connections due to voltage circuit shorting or current circuit breaking caused by incorrect or erroneous actions of personnel. Findings. Four main types of defects in accounting schemes are identified. It is shown that the imbalance between commercial and technical accounting can be used to identify defects in the tire section. Criteria for the rapid identification of defective connections based on statistical methods such as correlation analysis and one-factor analysis of variance are developed. Originality. In contrast to the existing approach, the sequence is proposed and the criteria for finding a connection with a metering defect are developed using the analytical method. As a result, it will be necessary to replace the metering device or device only at one connection connected to the busbar section with a defect in the metering circuits. The analytical method is based on the processing of metering data and the calculation of several statistical coefficients. Practical value. The proposed methodology enables the rapid identification of a defective metering device using an analytical method. It ensures fast and accurate detection of defective connections on the busbar section, helping to avoid emergency situations and energy losses. This makes the methodology valuable for industrial enterprises with high energy consumption.
Title: Method for identifying a connection with a metering defect among multiple connections on a single busbar section
Description:
Purpose.
The purpose of this work is to develop a methodology for identifying a defective connection on a single medium- or low-voltage busbar section among several parallel connections.
Methodology.
As is known, from three to two dozen connections can be powered simultaneously from the busbar section of the main step-down substation with a higher voltage of 35÷154 kV, a dead-end substation with a medium voltage of 10 (6) kV or a transformer substation with a voltage of 10 (6)/0.
4 kV.
A metering device defect on one of these connections can only be detected using the balance method (where a metering device, usually for commercial purposes, is installed at the busbar section input, and each outgoing connection from the busbar section is also equipped with an electricity meter).
The search for a defective metering device is carried out by inspecting all metering devices for each connection.
Among them, the defective device is identified.
However, this procedure often takes a significant amount of time, requires the implementation of organizational and technical measures when working in operational electrical installations, and can lead to emergency disconnections of connections due to voltage circuit shorting or current circuit breaking caused by incorrect or erroneous actions of personnel.
Findings.
Four main types of defects in accounting schemes are identified.
It is shown that the imbalance between commercial and technical accounting can be used to identify defects in the tire section.
Criteria for the rapid identification of defective connections based on statistical methods such as correlation analysis and one-factor analysis of variance are developed.
Originality.
In contrast to the existing approach, the sequence is proposed and the criteria for finding a connection with a metering defect are developed using the analytical method.
As a result, it will be necessary to replace the metering device or device only at one connection connected to the busbar section with a defect in the metering circuits.
The analytical method is based on the processing of metering data and the calculation of several statistical coefficients.
Practical value.
The proposed methodology enables the rapid identification of a defective metering device using an analytical method.
It ensures fast and accurate detection of defective connections on the busbar section, helping to avoid emergency situations and energy losses.
This makes the methodology valuable for industrial enterprises with high energy consumption.

Related Results

PERANCANGAN PENINGKATAN KEANDALAN SISTEM TENAGA LISTRIK PADA GARDU HUBUNG POKA
PERANCANGAN PENINGKATAN KEANDALAN SISTEM TENAGA LISTRIK PADA GARDU HUBUNG POKA
Proses pendistribusian di Pusat Listrik Poka dimulai dari Gardu Hubung (GH) Poka dimana terdapat 4 busbar (rel daya) 20 KV yaitu busbar 20 KV Ansaldo, busbar 20 KV Siemens, busbar ...
Pengembangan Relai Adaptif Proteksi Busbar Menggunakan Relai Berbasis Protokol IEC61850
Pengembangan Relai Adaptif Proteksi Busbar Menggunakan Relai Berbasis Protokol IEC61850
Kebutuhan manusia akan energi listrik bisa dikatakan mendekati kebutuhan primer. Sejalan dengan hal tersebut, PLN sebagai operator listrik di Indonesia, harus menjamin keandalan pa...
Features of field modeling of electromagnetic processes of trolley busbar
Features of field modeling of electromagnetic processes of trolley busbar
Purpose. Research and analysis trolley busbar’s parameters in condition of higher current harmonic actions, with taking into account the structural features of nonlinearity of magn...
Design and simulation for seeding performance of high-speed inclined corn metering device based on discrete element method (DEM)
Design and simulation for seeding performance of high-speed inclined corn metering device based on discrete element method (DEM)
AbstractMechanical precision corn seed-metering planter has a compact structure, missed and repeated seeding advantages during high-speed operation. In this regard, the current res...
Numerical Analysis of a Spiral Tube Damping Busbar to Suppress VFTO in 1000 kV GIS
Numerical Analysis of a Spiral Tube Damping Busbar to Suppress VFTO in 1000 kV GIS
Gas insulated substations (GISs) are broadly used for transmission and distribution in electric power networks. Very fast transient overvoltage (VFTO) caused by SF6 discharge durin...
Peculiarities of overhead crane movement mechanism operation when powered by a basbar's trolley at action of higher current harmonics
Peculiarities of overhead crane movement mechanism operation when powered by a basbar's trolley at action of higher current harmonics
Purpose. Analysis and research of interconnected electromagnetic processes between electric drives of overhead crane moving mechanism and trolleys under conditions of higher curren...
A technical and financial analysis of smart prepaid split meters on Eskom's electric power distribution
A technical and financial analysis of smart prepaid split meters on Eskom's electric power distribution
The implementation of a smart metering system in the distribution network does not only promote energy loss reduction, but also improves smart grids. This improvement in smart grid...
A low stray inductance laminated busbar for series-parallel capacitors
A low stray inductance laminated busbar for series-parallel capacitors
Abstract In the dynamic characteristics test circuit for high-voltage and high-power power electronic devices, the laminated busbar is the main connecting component....

Back to Top