Javascript must be enabled to continue!
Effects of Electro Osmotic Consolidation in South West of Johor: Small Laboratory Scale
View through CrossRef
Clay soil is one of the problematic soils due to its natural states which have low bearing capacity and high compressibility. The effect and problem of the clay soil characteristic creates a problem for construction especially excessive settlement and this can lead to unstable and potential cracks of engineering structures. At presents, there are few of soil improvement types can be carried out to overcome these problems, and electro osmotic consolidation is one of the options. This method has been applied many years ago especially in european countries. The study encompasses the determination of water content, atterberg’s limits and undrained shear strength after electro osmotic consolidation treatment of clay soils taken from 0.5 m and 1.5 m at southwest part of johor. All the samples were tested according to BS1377:1990. An experimental study was implemented in a pvc cylinder tube having dimensions of 300 mm height and 100 mm diameter. In the results of electro osmotic consolidation tests by installing copper spring electrodes, the measured undrained shear strength was increased considerably at the anodes especially compared to the initial undrained shear strength due to electro osmosis process and consolidation. As laboratory studies of its measurement have shown, the application of electro osmotic consolidation after the application of a direct current applied voltage of 10 volts, at the anodes especially: (i) a decrease by approximately 35% in water content; (ii) an increase around 29% in undrained shear strength; and (iii) a decrease about 21% in index plasticity. The results obtained in this study shows that the electro osmotic enhanced 15 kpa vertical loading consolidation is a feasible approach in strengthening of south west soft clay in johor. It can be clearly suggested that the higher the voltage applied in the system, the higher readings of undrained shear strength and the lower of water content especially at the anodes.
Trans Tech Publications, Ltd.
Title: Effects of Electro Osmotic Consolidation in South West of Johor: Small Laboratory Scale
Description:
Clay soil is one of the problematic soils due to its natural states which have low bearing capacity and high compressibility.
The effect and problem of the clay soil characteristic creates a problem for construction especially excessive settlement and this can lead to unstable and potential cracks of engineering structures.
At presents, there are few of soil improvement types can be carried out to overcome these problems, and electro osmotic consolidation is one of the options.
This method has been applied many years ago especially in european countries.
The study encompasses the determination of water content, atterberg’s limits and undrained shear strength after electro osmotic consolidation treatment of clay soils taken from 0.
5 m and 1.
5 m at southwest part of johor.
All the samples were tested according to BS1377:1990.
An experimental study was implemented in a pvc cylinder tube having dimensions of 300 mm height and 100 mm diameter.
In the results of electro osmotic consolidation tests by installing copper spring electrodes, the measured undrained shear strength was increased considerably at the anodes especially compared to the initial undrained shear strength due to electro osmosis process and consolidation.
As laboratory studies of its measurement have shown, the application of electro osmotic consolidation after the application of a direct current applied voltage of 10 volts, at the anodes especially: (i) a decrease by approximately 35% in water content; (ii) an increase around 29% in undrained shear strength; and (iii) a decrease about 21% in index plasticity.
The results obtained in this study shows that the electro osmotic enhanced 15 kpa vertical loading consolidation is a feasible approach in strengthening of south west soft clay in johor.
It can be clearly suggested that the higher the voltage applied in the system, the higher readings of undrained shear strength and the lower of water content especially at the anodes.
Related Results
Perjuangan Wanita dalam Novel Surat-Surat Perempuan Johor
Perjuangan Wanita dalam Novel Surat-Surat Perempuan Johor
Novel berunsur sejarah berjudul Surat-Surat Perempuan Johor (2005) merupakan novel tentang sejarah negeri Johor yang ditulis oleh Faisal Tehrani dan memenangi tempat ketiga dalam S...
Formulation development and evaluation of osmotic drug delivery system for lornoxicam
Formulation development and evaluation of osmotic drug delivery system for lornoxicam
Osmotic systems are the most reliable controlled drug delivery systems and can be employed as oral drug delivery systems. Osmotic pressure is used as the driving force for these sy...
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
<p><em><span class="markedContent"><span style="left: calc(var(--scale-factor)*195.53px); top: calc(var(--scale-factor)*496.87px); font-size: calc(var(--scale-...
Metodologi Pengeluaran Fatwa di Jawatankuasa Fatwa Negeri Johor
Metodologi Pengeluaran Fatwa di Jawatankuasa Fatwa Negeri Johor
In the discipline of Islamic law research, strong proofing and clear Istinbat method are key pillars in the construction of Islamic law based on the application of the science of u...
In-Situ Measurement and Analysis of Water Movement in PEFCs
In-Situ Measurement and Analysis of Water Movement in PEFCs
Polymer electrolyte fuel cells (PEFCs) are promising devices for power generation, portable and automotive applications. For the next generation of PEFCs, it is promising to operat...
KEDUDUKAN AHLI BAHASA DALAM PEMBUKTIAN PERKARA PENCEMARAN NAMA BAIK (STUDI PUTUSAN NOMOR: 47/PID.SUS/2019/PN. MGT)
KEDUDUKAN AHLI BAHASA DALAM PEMBUKTIAN PERKARA PENCEMARAN NAMA BAIK (STUDI PUTUSAN NOMOR: 47/PID.SUS/2019/PN. MGT)
<em><span id="page3R_mcid52" class="markedContent"><span style="left: calc(var(--scale-factor)*125.30px); top: calc(var(--scale-factor)*539.11px); font-size: calc(va...
Pendidikan Melayu Dan Agama di Johor Bahru, 1857-1957
Pendidikan Melayu Dan Agama di Johor Bahru, 1857-1957
Sebelum kedatangan British, masyarakat Melayu di Johor mempunyai corak pendidikan tersendiri berdasarkan asas pendidikan Islam dan al-Quran. Institusi pendidikan tradisional ini di...
Application of additional voltage in electric spark processing
Application of additional voltage in electric spark processing
This article discusses the current problem of obtaining thick-layer electro spark coatings with small roughness, and presents studies of the effect of additionally introduced volta...

