Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Evaluation of the impact of using a steerable sheath and bubble filters on the incidence of asymptomatic brain lesions following atrial fibrillation (AF) ablation

View through CrossRef
Abstract Introduction and Objectives Asymptomatic brain lesions are a common complication of AF ablation, with proposed mechanisms including air or steam embolism, plasma protein coagulation, and thrombus formation. This study aims to investigate whether the use of a steerable sheath for the ablation catheter and bubble filters can impact the incidence of asymptomatic brain lesions detectable by MRI after atrial fibrillation (AF) ablation. Methods The POWER FAST III study compared pulmonary vein ablation using conventional power delivered radiofrequency (CPD) with 25-40W versus high power (70W) and short duration (9–10s, HPSD). A cerebral MRI substudy was conducted on consecutive patients within <24 hours after ablation to detect acute ischemic brain lesions (DWI+ sequence). The effect of using or not using a steerable sheath (S+/S-) for the ablation catheter and bubble filters (F+/F-) in the perfusion lines (transseptal sheath, steerable sheath, and irrigation of the ablation catheter) was studied across 4 groups of consecutive patients (S+/F+, S+/F-, S-/F+, S-/F-) to assess the incidence of this complication. Results A total of 141 patients were included (60±11 years, 71% male, persistent AF 38%, CPD group 47%, and HPSD group 53%). The distribution by subgroup was S+/F+ 33 patients, S+/F- 52 patients, S-/F+ 43 patients, and S-/F- 13 patients. DWI+ lesions were detected in 58 (41%) patients, being more frequent in persistent AF cases (55% vs 45%, P=0.01) and in the HPSD group (67% vs 33%, P<0.01). The incidence of lesions by sheath and filter usage was: S+/F- 21 (40%), S+/F+ 13 (40%), S-/F+ 20 (46%), and S-/F- 4 (30%), P=0.77. Neither the use of a steerable sheath nor bubble filters, analyzed independently, was associated with a significantly different rate of brain lesions (V+ 40% vs V- 43%, P=0.74 and F+ 45% vs F- 38%, P=0.48). Conclusions The use of bubble filters and the avoidance of a steerable sheath do not reduce the incidence of asymptomatic brain lesions following atrial fibrillation (AF) ablation
Title: Evaluation of the impact of using a steerable sheath and bubble filters on the incidence of asymptomatic brain lesions following atrial fibrillation (AF) ablation
Description:
Abstract Introduction and Objectives Asymptomatic brain lesions are a common complication of AF ablation, with proposed mechanisms including air or steam embolism, plasma protein coagulation, and thrombus formation.
This study aims to investigate whether the use of a steerable sheath for the ablation catheter and bubble filters can impact the incidence of asymptomatic brain lesions detectable by MRI after atrial fibrillation (AF) ablation.
Methods The POWER FAST III study compared pulmonary vein ablation using conventional power delivered radiofrequency (CPD) with 25-40W versus high power (70W) and short duration (9–10s, HPSD).
A cerebral MRI substudy was conducted on consecutive patients within <24 hours after ablation to detect acute ischemic brain lesions (DWI+ sequence).
The effect of using or not using a steerable sheath (S+/S-) for the ablation catheter and bubble filters (F+/F-) in the perfusion lines (transseptal sheath, steerable sheath, and irrigation of the ablation catheter) was studied across 4 groups of consecutive patients (S+/F+, S+/F-, S-/F+, S-/F-) to assess the incidence of this complication.
Results A total of 141 patients were included (60±11 years, 71% male, persistent AF 38%, CPD group 47%, and HPSD group 53%).
The distribution by subgroup was S+/F+ 33 patients, S+/F- 52 patients, S-/F+ 43 patients, and S-/F- 13 patients.
DWI+ lesions were detected in 58 (41%) patients, being more frequent in persistent AF cases (55% vs 45%, P=0.
01) and in the HPSD group (67% vs 33%, P<0.
01).
The incidence of lesions by sheath and filter usage was: S+/F- 21 (40%), S+/F+ 13 (40%), S-/F+ 20 (46%), and S-/F- 4 (30%), P=0.
77.
Neither the use of a steerable sheath nor bubble filters, analyzed independently, was associated with a significantly different rate of brain lesions (V+ 40% vs V- 43%, P=0.
74 and F+ 45% vs F- 38%, P=0.
48).
Conclusions The use of bubble filters and the avoidance of a steerable sheath do not reduce the incidence of asymptomatic brain lesions following atrial fibrillation (AF) ablation.

Related Results

Brain Organoids, the Path Forward?
Brain Organoids, the Path Forward?
Photo by Maxim Berg on Unsplash INTRODUCTION The brain is one of the most foundational parts of being human, and we are still learning about what makes humans unique. Advancements ...
Inter‐Relationships Between Atrial Flutter and Atrial Fibrillation
Inter‐Relationships Between Atrial Flutter and Atrial Fibrillation
It has been appreciated for a long time that atrial flutter and atrial fibrillation have a clinical relationship. Now, with the technological advances that permit more sophisticate...
Steerable Delivery Sheath for Optimized LAA Closure: First Experience and Procedural Outcomes
Steerable Delivery Sheath for Optimized LAA Closure: First Experience and Procedural Outcomes
ABSTRACTBackgroundThe new Amplatzer Steerable Delivery Sheath is a delivery system designed to improve ease‐of‐use and procedural results of left atrial appendage closure (LAAC). W...
La enfermera experta en fibrilación auricular
La enfermera experta en fibrilación auricular
La fibrilación auricular es la arritmia cardiaca más prevalente de nuestro entorno. Las clínicas de fibrilación auricular lideradas por enfermería nacen para garantizar el manejo i...
The Canberra Bubble
The Canberra Bubble
According to the ABC television program Four Corners, “Parliament House in Canberra is a hotbed of political intrigue and high tension … . It’s known as the ‘Canberra Bubble’ and i...
Enhanced Procedural Efficacy in Typical Atrial Flutter Ablation With a Visualizable Steerable Sheath
Enhanced Procedural Efficacy in Typical Atrial Flutter Ablation With a Visualizable Steerable Sheath
ABSTRACTObjectiveThe Vizigo sheath, a novel visualizable steerable sheath, has been utilized effectively in the clinical management of atrial fibrillation. However, its application...
Adiponectin and Lone atrial fibrillation
Adiponectin and Lone atrial fibrillation
Objective: Lone atrial fibrillation is an idiopathic arrhythmia seen in younger individuals without any secondary disease. Adiponectin is an endogenous adipocytokine that increases...

Back to Top