Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Enhanced Procedural Efficacy in Typical Atrial Flutter Ablation With a Visualizable Steerable Sheath

View through CrossRef
ABSTRACTObjectiveThe Vizigo sheath, a novel visualizable steerable sheath, has been utilized effectively in the clinical management of atrial fibrillation. However, its application in the ablation of typical atrial flutter (AFL) remains unexplored. This study aims to evaluate and compare the efficacy and safety of the Vizigo sheath against a conventional fixed sheath during catheter ablation for typical AFL.MethodsThis single‐center cohort study involved 60 patients undergoing their first AFL ablation procedure. Patients were divided into two groups: the Vizigo sheath group and the fixed sheath group. The primary endpoints included procedural efficiency, lesion quality, and recurrence rates.ResultsThe Vizigo sheath demonstrated significant advantages over the fixed sheath, including a shorter procedure time (59.8 ± 13.8 vs. 71.5 ± 11.8 min; p = 0.0008) and reduced fluoroscopy duration (0.96 ± 0.32 vs. 1.31 ± 0.24 min; p < 0.0001). The initial bidirectional block rate was also higher in the Vizigo sheath group (84% vs. 68%). A detailed analysis of the cavotricuspid isthmus (CTI) revealed significant differences in the anterior 2/3 of the CTI, where the Vizigo sheath demonstrated greater catheter contact force, higher ablation index, increased force‐time integral, and larger impedance drops (all p < 0.05). In contrast, no significant differences were observed between groups in the posterior 1/3 of the CTI. Both groups achieved a 100% acute procedural success rate, with no major complications reported. During a mean follow‐up period of 18.68 months, the AFL recurrence rates were comparable between the two groups (p = 0.75).ConclusionsThe Vizigo sheath enhances procedural efficiency and lesion quality during AFL ablation, particularly in challenging anatomical regions, and offers notable advantages over traditional fixed sheaths. Further studies are needed to assess its long‐term clinical benefits.
Title: Enhanced Procedural Efficacy in Typical Atrial Flutter Ablation With a Visualizable Steerable Sheath
Description:
ABSTRACTObjectiveThe Vizigo sheath, a novel visualizable steerable sheath, has been utilized effectively in the clinical management of atrial fibrillation.
However, its application in the ablation of typical atrial flutter (AFL) remains unexplored.
This study aims to evaluate and compare the efficacy and safety of the Vizigo sheath against a conventional fixed sheath during catheter ablation for typical AFL.
MethodsThis single‐center cohort study involved 60 patients undergoing their first AFL ablation procedure.
Patients were divided into two groups: the Vizigo sheath group and the fixed sheath group.
The primary endpoints included procedural efficiency, lesion quality, and recurrence rates.
ResultsThe Vizigo sheath demonstrated significant advantages over the fixed sheath, including a shorter procedure time (59.
8 ± 13.
8 vs.
71.
5 ± 11.
8 min; p = 0.
0008) and reduced fluoroscopy duration (0.
96 ± 0.
32 vs.
1.
31 ± 0.
24 min; p < 0.
0001).
The initial bidirectional block rate was also higher in the Vizigo sheath group (84% vs.
68%).
A detailed analysis of the cavotricuspid isthmus (CTI) revealed significant differences in the anterior 2/3 of the CTI, where the Vizigo sheath demonstrated greater catheter contact force, higher ablation index, increased force‐time integral, and larger impedance drops (all p < 0.
05).
In contrast, no significant differences were observed between groups in the posterior 1/3 of the CTI.
Both groups achieved a 100% acute procedural success rate, with no major complications reported.
During a mean follow‐up period of 18.
68 months, the AFL recurrence rates were comparable between the two groups (p = 0.
75).
ConclusionsThe Vizigo sheath enhances procedural efficiency and lesion quality during AFL ablation, particularly in challenging anatomical regions, and offers notable advantages over traditional fixed sheaths.
Further studies are needed to assess its long‐term clinical benefits.

Related Results

Inter‐Relationships Between Atrial Flutter and Atrial Fibrillation
Inter‐Relationships Between Atrial Flutter and Atrial Fibrillation
It has been appreciated for a long time that atrial flutter and atrial fibrillation have a clinical relationship. Now, with the technological advances that permit more sophisticate...
Steerable Delivery Sheath for Optimized LAA Closure: First Experience and Procedural Outcomes
Steerable Delivery Sheath for Optimized LAA Closure: First Experience and Procedural Outcomes
ABSTRACTBackgroundThe new Amplatzer Steerable Delivery Sheath is a delivery system designed to improve ease‐of‐use and procedural results of left atrial appendage closure (LAAC). W...
Effects of Azimilide Dihydrochloride on Circus Movement Atrial Flutter in the Canine Sterile Pericarditis Model
Effects of Azimilide Dihydrochloride on Circus Movement Atrial Flutter in the Canine Sterile Pericarditis Model
Azimilide and Atrial Flutter. Introduction: The effects of a Class III agent, azimilide di‐hydrochloride, on atrial flutter circuits were studied in a functional model of single lo...
E-071 Organization of a Neurointerventional Fellowship Curriculum
E-071 Organization of a Neurointerventional Fellowship Curriculum
Introduction The field of Neurointervention has attracted some of the very best physicians across the world. Given the interdisciplinary nature of this specialty,...
Closed-loop identification for aircraft flutter model parameters
Closed-loop identification for aircraft flutter model parameters
Purpose The purpose of this paper is to extend the authors’ previous contributions on aircraft flutter model parameters identification. Because closed-loop condition is more widely...

Back to Top