Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Modes of bioprosthetic valve failure: a narrative review

View through CrossRef
Purpose of review A thorough understanding of the modes of bioprosthetic valve failure is critical as clinicians will be facing an increasing number of patients presenting with failed bioprostheses in coming years. The purpose of this article is to review modes of bioprosthestic valve degeneration, their management, and identify gaps for future research. Recent findings Guidelines recommend monitoring hemodynamic performance of prosthetic valves using serial echocardiograms to determine valve function and presence of valve degeneration. Modes of bioprosthetic valve failure may be categorized as structural degeneration (calcification, tears, fibrosis, flail), nonstructural degeneration (pannus), thrombosis, and endocarditis. Calcification is the most common form of structural valve degeneration. Predictors of bioprosthetic valve failure include valves implanted in the mitral position, younger age, and type of valve (porcine versus bovine pericardial). Failed bioprosthetic valves are managed with either redo surgical replacement or transcatheter valve-in-valve implantation. Summary Several modes of bioprosthetic valve failure exist, which vary based on patient, implant position, and valve characteristics. Further research is required to characterize factors associated with early failure to delay structural valve degeneration and improve patient prognosis.
Title: Modes of bioprosthetic valve failure: a narrative review
Description:
Purpose of review A thorough understanding of the modes of bioprosthetic valve failure is critical as clinicians will be facing an increasing number of patients presenting with failed bioprostheses in coming years.
The purpose of this article is to review modes of bioprosthestic valve degeneration, their management, and identify gaps for future research.
Recent findings Guidelines recommend monitoring hemodynamic performance of prosthetic valves using serial echocardiograms to determine valve function and presence of valve degeneration.
Modes of bioprosthetic valve failure may be categorized as structural degeneration (calcification, tears, fibrosis, flail), nonstructural degeneration (pannus), thrombosis, and endocarditis.
Calcification is the most common form of structural valve degeneration.
Predictors of bioprosthetic valve failure include valves implanted in the mitral position, younger age, and type of valve (porcine versus bovine pericardial).
Failed bioprosthetic valves are managed with either redo surgical replacement or transcatheter valve-in-valve implantation.
Summary Several modes of bioprosthetic valve failure exist, which vary based on patient, implant position, and valve characteristics.
Further research is required to characterize factors associated with early failure to delay structural valve degeneration and improve patient prognosis.

Related Results

Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
The medtronic melody® transcatheter pulmonary valve implanted at 24‐mm diameter—it works
The medtronic melody® transcatheter pulmonary valve implanted at 24‐mm diameter—it works
ObjectivesWe report the Melody valve implanted and/or expanded to 24‐mm diameter.BackgroundThe Medtronic Melody valve has been implanted up to 22 mm in the pulmonary position for o...
An Acoustically Controlled Down-Hole Safety Valve (SCSSSV)
An Acoustically Controlled Down-Hole Safety Valve (SCSSSV)
American Institute of Mining, Metallurgical, and Petroleum Engineers, Inc. Abstract A surface-controlled subsurface safety valve...
Uniformity in bioprosthetic mitral valve sizing -- when will we get there?
Uniformity in bioprosthetic mitral valve sizing -- when will we get there?
Much has changed since the introduction of surgical valve repair in the 1950s, from the introduction bioprosthetic valves to percutaneous approaches to valve repair. Yet, despite s...
Comparison of Heart Valve Circumference Examined Before and After 10% Formalin Fixation
Comparison of Heart Valve Circumference Examined Before and After 10% Formalin Fixation
Objective: To compare the heart valve circumference before and after 10% formalin fixation. Materials and Methods: The study analyzed 63 Thai human cadaveric hearts. Each heart val...