Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparison of Heart Valve Circumference Examined Before and After 10% Formalin Fixation

View through CrossRef
Objective: To compare the heart valve circumference before and after 10% formalin fixation. Materials and Methods: The study analyzed 63 Thai human cadaveric hearts. Each heart valve circumference was separately measured in the fresh state by specifically designed equipment. After that, the hearts were fixed in 10% formalin for 3 days. Then each heart valve circumference was measured by the same equipment and by the thread and ruler technique. The results were analyzed using SPSS package to find the association between the heart valve circumference before and after formalin fixation. Results: This study showed that the average circumferences of the heart valve measured in the fresh state were 13.329 cm in the tricuspid valve, 10.617 cm in the mitral valve, 8.416 cm in the pulmonic valve, and 7.122 cm in the aortic valve. The average circumferences of the heart valve measured after 10% formalin fixation were 11.019 cm in the tricuspid valve, 8.714 cm in the mitral valve, 6.751 cm in the pulmonic valve, and 6.089 cm in the aortic valve. The average ratios of the heart valve circumference measured fresh and after 10% formalin fixation were 0.8267 in the tricuspid valve, 0.8235 in the mitral valve, 0.8050 in the pulmonic valve, and 0.8573 in the aortic valve. There were significant differences in the heart valve circumference between the fresh state and after formalin fixation (p < 0.001). Conclusion: This study revealed important information on the dimensional changes of all the formalin-fixed heart valves. We found that the heart valve shrank after formalin fixation, with the formalin-fixed hearts an estimated 0.8 times smaller than the fresh cadaveric hearts.
Title: Comparison of Heart Valve Circumference Examined Before and After 10% Formalin Fixation
Description:
Objective: To compare the heart valve circumference before and after 10% formalin fixation.
Materials and Methods: The study analyzed 63 Thai human cadaveric hearts.
Each heart valve circumference was separately measured in the fresh state by specifically designed equipment.
After that, the hearts were fixed in 10% formalin for 3 days.
Then each heart valve circumference was measured by the same equipment and by the thread and ruler technique.
The results were analyzed using SPSS package to find the association between the heart valve circumference before and after formalin fixation.
Results: This study showed that the average circumferences of the heart valve measured in the fresh state were 13.
329 cm in the tricuspid valve, 10.
617 cm in the mitral valve, 8.
416 cm in the pulmonic valve, and 7.
122 cm in the aortic valve.
The average circumferences of the heart valve measured after 10% formalin fixation were 11.
019 cm in the tricuspid valve, 8.
714 cm in the mitral valve, 6.
751 cm in the pulmonic valve, and 6.
089 cm in the aortic valve.
The average ratios of the heart valve circumference measured fresh and after 10% formalin fixation were 0.
8267 in the tricuspid valve, 0.
8235 in the mitral valve, 0.
8050 in the pulmonic valve, and 0.
8573 in the aortic valve.
There were significant differences in the heart valve circumference between the fresh state and after formalin fixation (p < 0.
001).
Conclusion: This study revealed important information on the dimensional changes of all the formalin-fixed heart valves.
We found that the heart valve shrank after formalin fixation, with the formalin-fixed hearts an estimated 0.
8 times smaller than the fresh cadaveric hearts.

Related Results

An Acoustically Controlled Down-Hole Safety Valve (SCSSSV)
An Acoustically Controlled Down-Hole Safety Valve (SCSSSV)
American Institute of Mining, Metallurgical, and Petroleum Engineers, Inc. Abstract A surface-controlled subsurface safety valve...
Alat Pendeteksi Formalin Menggunakan Deret Sensor HCHO dan MQ-7 dengan Logika Fuzzy
Alat Pendeteksi Formalin Menggunakan Deret Sensor HCHO dan MQ-7 dengan Logika Fuzzy
Formalin merupakan zat kimia berbahaya yang memiliki bau menyengat, tidak memiliki warna atau jernih, dan mudah terbakar. Formalin, yang seharusnya digunakan untuk bahan pengawet m...
Histomorphological Comparison of Tissues Fixed in Conventional Formalin and Eco-friendly Jaggery Solution: A Cross-sectional Study
Histomorphological Comparison of Tissues Fixed in Conventional Formalin and Eco-friendly Jaggery Solution: A Cross-sectional Study
Introduction: Tissue fixation is an essential step in the microscopic preparation of tissues to preserve them by preventing autolysis, bacterial putrefaction, and increasing the ti...
Phosphate-buffered Formalin Fixative Under Controlled Fixation Temperature Yielded Excellently Preserved Histomorphology
Phosphate-buffered Formalin Fixative Under Controlled Fixation Temperature Yielded Excellently Preserved Histomorphology
Aim: Using mouse liver as experimental model, this study attempts to identify a formalin-based fixative and fixation temperature that jointly provides the best balance of preservat...
Comparing 3 Different Techniques of Patella Fracture Fixation and Their Complications
Comparing 3 Different Techniques of Patella Fracture Fixation and Their Complications
Introduction: Patella fractures managed by fixation with metal implants often cause local soft tissue irritation and necessitate implant removal. An alternative is to utilize sutur...
The Critical Role of Presettable and Expandable Artificial Surgical Valves in the Lifetime Management of Valvular Heart Disease
The Critical Role of Presettable and Expandable Artificial Surgical Valves in the Lifetime Management of Valvular Heart Disease
With the trend of younger patients undergoing surgical valve replacement and increased life expectancy, how to account for subsequent therapies during the initial valve replacement...
Reciprocating compressor valve damage estimation under varying speeds through the acoustic emission technique
Reciprocating compressor valve damage estimation under varying speeds through the acoustic emission technique
Purpose The purpose of this paper is to examine the effect of reciprocating compressor speeds and valve conditions on the roor-mean-square (RMS) value of burst acoustic emission (A...

Back to Top