Javascript must be enabled to continue!
Ozone disinfection of home nebulizers effectively kills common cystic fibrosis bacterial pathogens
View through CrossRef
AbstractObjectiveThe Cystic Fibrosis Foundation (CFF) recommends routine nebulizer disinfection for patients but compliance is challenging due to the heavy burden of home care. SoClean® is a user friendly ozone based home disinfection device currently for home respiratory equipment. The objective of this study was to determine whether SoClean® has potential as a disinfection device for families with CF by killing CF associated bacteria without altering nebulizer output.HypothesisOzone based disinfection effectively kills bacterial pathogens inoculated to home nebulizer equipment without gross changes in nebulizer function.Study DesignCommon bacterial pathogens associated with CF were inoculated onto the PariLC® jet nebulizer and bacterial recovery compared with or without varied ozone exposure. In separate experiments, nebulizer output was estimated after repeated ozone exposure by weighing the nebulizer.ResultsOzone disinfection was time dependent with a 5 min infusion time and 120 min dwell time effectively killing >99.99% bacteria tested including Pseudomonas aeruginosa and Staphylococcus aureus. Over 250 h of repeat ozone exposure did not alter nebulizer output. This suggests SoClean® has potential as a user‐friendly disinfection technique for home respiratory equipment.
Title: Ozone disinfection of home nebulizers effectively kills common cystic fibrosis bacterial pathogens
Description:
AbstractObjectiveThe Cystic Fibrosis Foundation (CFF) recommends routine nebulizer disinfection for patients but compliance is challenging due to the heavy burden of home care.
SoClean® is a user friendly ozone based home disinfection device currently for home respiratory equipment.
The objective of this study was to determine whether SoClean® has potential as a disinfection device for families with CF by killing CF associated bacteria without altering nebulizer output.
HypothesisOzone based disinfection effectively kills bacterial pathogens inoculated to home nebulizer equipment without gross changes in nebulizer function.
Study DesignCommon bacterial pathogens associated with CF were inoculated onto the PariLC® jet nebulizer and bacterial recovery compared with or without varied ozone exposure.
In separate experiments, nebulizer output was estimated after repeated ozone exposure by weighing the nebulizer.
ResultsOzone disinfection was time dependent with a 5 min infusion time and 120 min dwell time effectively killing >99.
99% bacteria tested including Pseudomonas aeruginosa and Staphylococcus aureus.
Over 250 h of repeat ozone exposure did not alter nebulizer output.
This suggests SoClean® has potential as a user‐friendly disinfection technique for home respiratory equipment.
Related Results
Physiological response of Garlic (Allium sativum) to elevated tropospheric ozone in high altitude region of Western Ghats, Tamil Nadu, India
Physiological response of Garlic (Allium sativum) to elevated tropospheric ozone in high altitude region of Western Ghats, Tamil Nadu, India
Abstract
A pot culture study was conducted at Horticultural Research Station, Ooty, to assess the effect of ground-level ozone on physiology in garlic plants and find out s...
Prostor doma u hrvatskim igranim filmovima s temom domovinskog rata
Prostor doma u hrvatskim igranim filmovima s temom domovinskog rata
The dissertation explores the formation of domestic space in contemporary Croatian society through its presentations in the medium of feature films. The cinematic domestic spaces a...
Enhanced climate response to ozone depletion from ozone-circulation coupling
Enhanced climate response to ozone depletion from ozone-circulation coupling
The effect of stratospheric ozone depletion is simulated in GFDL AM4
model with three ozone schemes: prescribing monthly zonal mean ozone
concentration, full interactive stratosphe...
Research on the stratospheric ozone depletion in the polar spring
Research on the stratospheric ozone depletion in the polar spring
In recent years, the severe stratospheric ozone depletion events (ODEs) were reported in the polar spring. We retrieved the critical indicator ozone vertical column densities (VCDs...
Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model
Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model
Abstract
Dissolved ozone is generally used for sanitization, but it has not been used for thoracic cavity sanitization because of its short half-life (< 20 min) and poss...
Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model
Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model
Abstract
Dissolved ozone is generally used for sanitization, but it has not been used for thoracic cavity sanitization because of its short h...
Vertical distribution of ozone in summer and autumn in Guangdong Province, Southern China
Vertical distribution of ozone in summer and autumn in Guangdong Province, Southern China
<p>A differential absorption lidar was used to study the vertical structure of ozone in Jiangmen city and Yangjiang city, Guangdong Province, Southern China in summer...
Comparative Evaluation of Disinfection on Elastomeric Impression Material using 2% Gluteraldehyde, Ultra Violet Radiation and Gaseous Ozone using Customised Disinfection Unit - An In-Vitro Study
Comparative Evaluation of Disinfection on Elastomeric Impression Material using 2% Gluteraldehyde, Ultra Violet Radiation and Gaseous Ozone using Customised Disinfection Unit - An In-Vitro Study
Dental impressions is the preliminary step for any procedure and acts as a microbial source leading to contamination to the operator and lab technician. Hence, the disinfection of ...

