Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model

View through CrossRef
Abstract Dissolved ozone is generally used for sanitization, but it has not been used for thoracic cavity sanitization because of its short half-life (< 20 min) and possible toxicity. We developed a novel solution containing ultrafine ozone bubbles (ozone-UFB) with a fivefold longer half-life than non-UFB ozone. Using an in vitro model, Staphylococcus aureus colonies were counted after exposure to ozone-UFB or non-UFB ozone at the same ozone concentration (0.4 mg/L). The colony count was significantly lower in the ozone-UFB group than in the non-UFB ozone group ( p  = 0.034). The effect of repeated pleural irrigation using ozone-UFB and saline was compared in a rat empyema model of S. aureus infection. The bacterial count in the pleural effusion was decreased by at least fivefold following intrathoracic lavage with ozone-UFB (3 mg/L). To examine the safety of ozone-UFB for intrathoracic use, ozone-UFB with a higher ozone concentration (10 mg/L) was injected into the thoracic cavities of normal rats. The treatment did not result in any specific pleural damage or elevated serum interleukin-6 concentrations. The findings highlighted the efficacy and safety of ozone-UFB for intrathoracic sanitization, but further studies are needed to determine the optimal therapeutic ozone concentration with appropriate safety margins.
Title: Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model
Description:
Abstract Dissolved ozone is generally used for sanitization, but it has not been used for thoracic cavity sanitization because of its short half-life (< 20 min) and possible toxicity.
We developed a novel solution containing ultrafine ozone bubbles (ozone-UFB) with a fivefold longer half-life than non-UFB ozone.
Using an in vitro model, Staphylococcus aureus colonies were counted after exposure to ozone-UFB or non-UFB ozone at the same ozone concentration (0.
4 mg/L).
The colony count was significantly lower in the ozone-UFB group than in the non-UFB ozone group ( p  = 0.
034).
The effect of repeated pleural irrigation using ozone-UFB and saline was compared in a rat empyema model of S.
aureus infection.
The bacterial count in the pleural effusion was decreased by at least fivefold following intrathoracic lavage with ozone-UFB (3 mg/L).
To examine the safety of ozone-UFB for intrathoracic use, ozone-UFB with a higher ozone concentration (10 mg/L) was injected into the thoracic cavities of normal rats.
The treatment did not result in any specific pleural damage or elevated serum interleukin-6 concentrations.
The findings highlighted the efficacy and safety of ozone-UFB for intrathoracic sanitization, but further studies are needed to determine the optimal therapeutic ozone concentration with appropriate safety margins.

Related Results

Challenging Management of Postoperative Empyema: A Case Report with Literature Review
Challenging Management of Postoperative Empyema: A Case Report with Literature Review
Abstract Introduction: Pleural empyema is the collection of pus within the pleural cavity, typically arising as a complication of pneumonia, chest trauma, thoracic surgery, or bact...
Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model
Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model
Abstract Dissolved ozone is generally used for sanitization, but it has not been used for thoracic cavity sanitization because of its short half-life (< 20 min) and poss...
Runahead threads
Runahead threads
Los temas de investigación sobre multithreading han ganado mucho interés en la arquitectura de computadores con la aparición de procesadores multihilo y multinucleo. Los procesador...
The role of medical thoracoscopy in the management of empyema
The role of medical thoracoscopy in the management of empyema
Abstract Background Empyema thoracis is defined as accumulation of pus in the pleural space. Despite advanced medical diagnostic and therapeutic met...
Research on the stratospheric ozone depletion in the polar spring
Research on the stratospheric ozone depletion in the polar spring
In recent years, the severe stratospheric ozone depletion events (ODEs) were reported in the polar spring. We retrieved the critical indicator ozone vertical column densities (VCDs...
Enhanced climate response to ozone depletion from ozone-circulation coupling
Enhanced climate response to ozone depletion from ozone-circulation coupling
The effect of stratospheric ozone depletion is simulated in GFDL AM4 model with three ozone schemes: prescribing monthly zonal mean ozone concentration, full interactive stratosphe...
Vertical distribution of ozone in summer and autumn in Guangdong Province, Southern China
Vertical distribution of ozone in summer and autumn in Guangdong Province, Southern China
&lt;p&gt;A differential absorption lidar was used to study the vertical structure of ozone in Jiangmen city and Yangjiang city, Guangdong Province, Southern China in summer...

Back to Top