Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparative Evaluation of Disinfection on Elastomeric Impression Material using 2% Gluteraldehyde, Ultra Violet Radiation and Gaseous Ozone using Customised Disinfection Unit - An In-Vitro Study

View through CrossRef
Dental impressions is the preliminary step for any procedure and acts as a microbial source leading to contamination to the operator and lab technician. Hence, the disinfection of these impressions materials should be carried out unfailingly. The device was fabricated which helped in easy and effective disinfection.Aim: The aim of the study is to Compare and Evaluate the Efficacy of Disinfection on Elastomeric Impression material using 2% Gluteraldehyde, UV Radiation Disinfection and Gaseous Ozone. Objective: The efficacy of the disinfectants was compared based on the ability of the disinfectants in reducing the microbial colonies on the impression material. Methodology: Microbiological analysis was done and the colony forming units were evaluated and compared. The disinfection was done with a customized disinfection chamber which can be readily installed in the clinic and has multitudes of use other than disinfection. Result: Dry Gaseous Ozone as a disinfectant proved to be efficacious as compared to the other disinfectants. Conclusion: Dry gaseous ozone can be used effectively for disinfection of impressions without altering its dimensional stability. The customized disinfection unit is portable and can be readily installed in the clinic.
Title: Comparative Evaluation of Disinfection on Elastomeric Impression Material using 2% Gluteraldehyde, Ultra Violet Radiation and Gaseous Ozone using Customised Disinfection Unit - An In-Vitro Study
Description:
Dental impressions is the preliminary step for any procedure and acts as a microbial source leading to contamination to the operator and lab technician.
Hence, the disinfection of these impressions materials should be carried out unfailingly.
The device was fabricated which helped in easy and effective disinfection.
Aim: The aim of the study is to Compare and Evaluate the Efficacy of Disinfection on Elastomeric Impression material using 2% Gluteraldehyde, UV Radiation Disinfection and Gaseous Ozone.
Objective: The efficacy of the disinfectants was compared based on the ability of the disinfectants in reducing the microbial colonies on the impression material.
Methodology: Microbiological analysis was done and the colony forming units were evaluated and compared.
The disinfection was done with a customized disinfection chamber which can be readily installed in the clinic and has multitudes of use other than disinfection.
Result: Dry Gaseous Ozone as a disinfectant proved to be efficacious as compared to the other disinfectants.
Conclusion: Dry gaseous ozone can be used effectively for disinfection of impressions without altering its dimensional stability.
The customized disinfection unit is portable and can be readily installed in the clinic.

Related Results

Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Effect of ozone and 10% sodium ascorbate on human dentin microhardness
Effect of ozone and 10% sodium ascorbate on human dentin microhardness
: Several strategies have been tried out for the control and antimicrobial treatment of carious lesions such as the direct application of ozone. However, the the oxidation process ...
Enhanced climate response to ozone depletion from ozone-circulation coupling
Enhanced climate response to ozone depletion from ozone-circulation coupling
The effect of stratospheric ozone depletion is simulated in GFDL AM4 model with three ozone schemes: prescribing monthly zonal mean ozone concentration, full interactive stratosphe...
Research on the stratospheric ozone depletion in the polar spring
Research on the stratospheric ozone depletion in the polar spring
In recent years, the severe stratospheric ozone depletion events (ODEs) were reported in the polar spring. We retrieved the critical indicator ozone vertical column densities (VCDs...
Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model
Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model
Abstract Dissolved ozone is generally used for sanitization, but it has not been used for thoracic cavity sanitization because of its short half-life (< 20 min) and poss...
Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model
Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model
Abstract Dissolved ozone is generally used for sanitization, but it has not been used for thoracic cavity sanitization because of its short h...

Back to Top