Javascript must be enabled to continue!
The Double Chooz antineutrino detectors
View through CrossRef
AbstractThis article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle $$\theta _{13}$$
θ
13
. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.
Springer Science and Business Media LLC
H. de Kerret
Y. Abe
C. Aberle
T. Abrahão
J. M. Ahijado
T. Akiri
J. M. Alarcón
J. Alba
H. Almazan
J. C. dos Anjos
S. Appel
F. Ardellier
I. Barabanov
J. C. Barriere
E. Baussan
A. Baxter
I. Bekman
M. Bergevin
A. Bernstein
W. Bertoli
T. J. C. Bezerra
L. Bezrukov
C. Blanco
N. Bleurvacq
E. Blucher
H. Bonet
M. Bongrand
N. S Bowden
T. Brugière
C. Buck
M. Buizza Avanzini
J. Busenitz
A. Cabrera
E. Caden
E. Calvo
L. Camilleri
R. Carr
S. Cazaux
J. M. Cela
M. Cerrada
P. J. Chang
P. Charon
E. Chauveau
P. Chimenti
T. Classen
A. P. Collin
E. Conover
J. M Conrad
S. Cormon
O. Corpace
B. Courty
J. I. Crespo-Anadón
M. Cribier
K. Crum
S. Cuadrado
A. Cucoanes
M. D’Agostino
E. Damon
J. V. Dawson
S. Dazeley
M. Dierckxsens
D. Dietrich
Z. Djurcic
F. Dorigo
M. Dracos
V. Durand
Y. Efremeko
M. Elnimr
A. Etenko
E. Falk
M. Fallot
M. Fechner
J. Felde
S. M. Fernandes
C. Fernández-Bedoya
D. Francia
D. Franco
V. Fischer
A. J. Franke
M. Franke
H. Furuta
F. Garcia
J. Garcia
I. Gil-Botella
L. Giot
A. Givaudan
M. Göger-Neff
H. Gomez
L. F. G. Gonzalez
L. Goodenough
M. C. Goodman
J. Goon
B. Gramlich
D. Greiner
A. Guertin
B. Guillon
S. M. Habib
Y. Haddad
T. Hara
F. X. Hartmann
J. Hartnell
J. Haser
A. Hatzikoutelis
D. Hellwig
S. Hervé
R. Hofacker
G. Horton-Smith
A. Hourlier
M. Ishitsuka
K. Jänner
S. Jiménez
J. Jochum
C. Jollet
F. Kaether
K. Kale
L. Kalousis
Y. Kamyshkov
M. Kaneda
D. M. Kaplan
M. Karakac
T. Kawasaki
E. Kemp
Y. Kibe
T. Kirchner
T. Konno
D. Kryn
T. Kutter
M. Kuze
T. Lachenmaier
C. E. Lane
C. Langbrandtner
T. Lasserre
C. Lastoria
L. Latron
C. Leonardo
A. Letourneau
D. Lhuillier
H. P. Lima
M. Lindner
J. M. López-Castaño
J. M. LoSecco
B. Lubsandorzhiev
S. Lucht
J. Maeda
C. N. Maesano
C. Mariani
J. Maricic
F. Marie
J. J. Martinez
J. Martino
T. Matsubara
D. McKee
F. Meigner
G. Mention
A. Meregaglia
J. P. Meyer
T. Miletic
R. Milincic
J. F. Millot
A. Minotti
V. Mirones
H. Miyata
Th. A. Mueller
Y. Nagasaka
K. Nakajima
D. Navas-Nicolás
Y. Nikitenko
P. Novella
L. Oberauer
M. Obolensky
A. Onillon
A. Oralbaev
I. Ostrovskiy
C. Palomares
S. J. M. Peeters
I. M. Pepe
S. Perasso
P. Perrin
P. Pfahler
A. Porta
G. Pronost
J. C. Puras
R. Quéval
J. L. Ramirez
J. Reichenbacher
B. Reinhold
M. Reissfelder
A. Remoto
D. Reyna
I. Rodriguez
M. Röhling
R. Roncin
N. Rudolf
B. Rybolt
Y. Sakamoto
R. Santorelli
F. Sato
U. Schwan
S. Schönert
S. Schoppmann
L. Scola
M. Settimo
M. A. Shaevitz
R. Sharankova
V. Sibille
J.-L. Sida
V. Sinev
D. Shrestha
M. Skorokhvatov
P. Soldin
J. Spitz
A. Stahl
I. Stancu
P. Starzynski
M. R. Stock
L. F. F. Stokes
M. Strait
A. Stüken
F. Suekane
S. Sukhotin
T. Sumiyoshi
Y. Sun
Z. Sun
R. Svoboda
H. Tabata
N. Tamura
K. Terao
A. Tonazzo
F. Toral
M. Toups
H. Trinh Thi
F. Valdivia
G. Valdiviesso
N. Vassilopoulos
A. Verdugo
C. Veyssiere
B. Viaud
D. Vignaud
M. Vivier
S. Wagner
C. Wiebusch
B. White
L. Winslow
M. Worcester
M. Wurm
J. Wurtz
G. Yang
J. Yáñez
F. Yermia
K. Zbiri
Title: The Double Chooz antineutrino detectors
Description:
AbstractThis article describes the setup and performance of the near and far detectors in the Double Chooz experiment.
The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores.
Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle $$\theta _{13}$$
θ
13
.
The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids.
From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system.
Above this main detector an additional outer veto system using plastic scintillator strips was installed.
The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field.
The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system.
The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.
Related Results
Fermi Degenerate Antineutrino Star Model of Dark Energy
Fermi Degenerate Antineutrino Star Model of Dark Energy
When the Large Hadron Collider resumes operations in 2021, several experiments will directly measure the motion of antihydrogen in free fall for the first time. Our current underst...
Abstract 1656: Quantifying task performance with photon-processing detectors
Abstract 1656: Quantifying task performance with photon-processing detectors
Abstract
Purpose. To estimate task performance (e.g., the ability to correctly detect a small lesion in a normal tissue) when the imaging system uses a new class of ...
Effects of the Multilayer Structure on the Responsivity of Pyroelectric Thin Film Detectors
Effects of the Multilayer Structure on the Responsivity of Pyroelectric Thin Film Detectors
AbstractPyroelectric thin film detectors have advantages of wavelength independent sensitivity, room temperature operation and direct incorporation with integrated circuit amplifie...
Neutrino Star Cosmology
Neutrino Star Cosmology
The ΛCDM model successfully models the expansion of matter in the universe with an expansion of the underlying metric. However, it does not address the physical origin o...
Antineutrino Star Model of the Big Bang and Dark Energy
Antineutrino Star Model of the Big Bang and Dark Energy
A new model of cosmology is proposed, where the state of high energy density commonly associated with the big bang is generated by the collapse of an antineutrino star that has exc...
Double-slit, Comprehensive-Double-Slit and Irregular-Double-Slit Experiments Showing That Light is Photons and It is Photons That Produce both Non-Interference Patterns and Interference Patterns in Same Experiment
Double-slit, Comprehensive-Double-Slit and Irregular-Double-Slit Experiments Showing That Light is Photons and It is Photons That Produce both Non-Interference Patterns and Interference Patterns in Same Experiment
Young’s double slit experiments have been descripted by wave theories, i.e., before and after passing through a double slit, the light is waves. To test the wave description, we ex...
Energy Calibration of Scintillator Detectors in Different Neutron Diagnostic System on Tokamak
Energy Calibration of Scintillator Detectors in Different Neutron Diagnostic System on Tokamak
The purpose of tokamak plasma diagnostics is to provide the necessary parameters for device protection, operation, and maintenance. It can also supply parameters for fusion physics...
Quantitative assessment of variation in CBCT image technical parameters related to CBCT detector lateral-offset position
Quantitative assessment of variation in CBCT image technical parameters related to CBCT detector lateral-offset position
Objectives: To assess the effect of CBCT detector position (aligned/lateral-offset) on image technical parameters (mean voxel value - MVV, standard deviation of voxel value (SDVV) ...

