Javascript must be enabled to continue!
Energy Calibration of Scintillator Detectors in Different Neutron Diagnostic System on Tokamak
View through CrossRef
The purpose of tokamak plasma diagnostics is to provide the necessary parameters for device protection, operation, and maintenance. It can also supply parameters for fusion physics research. As one of the main ways to diagnose nuclear fusion plasma, neutron diagnosis focuses on the detection of neutrons, produced by the D-D and D-T fusion reactions, to obtain the physical information of internal plasma. Neutron measurements are widely performed on tokamak to provide the essential information on the neutron yield rate of the plasma that is related to fusion power. Since neutron has no electric charge, neutron can’t be ionized directly by the interaction of electrons in the detection material. The interactions between neutron and nuclei, such as nuclear reaction and nuclear recoil, are used to detect neutrons. According to the front sensitive materials, neutron detectors can be divided into gas detectors, scintillator detectors, semiconductor detectors, ionization chambers and so on. Since the magnetic field surrounding Tokamak can have a magnificent influence on the performance of photo-electronic multiplier tubes (PMTs), it is necessary to employ magnetic shielding in designing detectors, thus guaranteeing the proper operation of detectors within a strong magnetic field. Although the PMTs are equipped with magnetic shielding materials by manufacturers, they can only resist the influence of geomagnetic field. Besides the magnetic shielding and neutron/gamma shielding, neutron detectors should be calibrated before used on the tokamak. Nine similar detectors were assembled and calibrated in this paper. The basic idea of processing calibration data is that we should adjust the resolution and the light response function in order to make experiment spectrum and simulation spectrum fit on the recoil proton edge. A special explication is given to the data processing of neutron calibration, followed by an analysis of its resulting light response function and by comparison with PTB’s results.
American Society of Mechanical Engineers
Title: Energy Calibration of Scintillator Detectors in Different Neutron Diagnostic System on Tokamak
Description:
The purpose of tokamak plasma diagnostics is to provide the necessary parameters for device protection, operation, and maintenance.
It can also supply parameters for fusion physics research.
As one of the main ways to diagnose nuclear fusion plasma, neutron diagnosis focuses on the detection of neutrons, produced by the D-D and D-T fusion reactions, to obtain the physical information of internal plasma.
Neutron measurements are widely performed on tokamak to provide the essential information on the neutron yield rate of the plasma that is related to fusion power.
Since neutron has no electric charge, neutron can’t be ionized directly by the interaction of electrons in the detection material.
The interactions between neutron and nuclei, such as nuclear reaction and nuclear recoil, are used to detect neutrons.
According to the front sensitive materials, neutron detectors can be divided into gas detectors, scintillator detectors, semiconductor detectors, ionization chambers and so on.
Since the magnetic field surrounding Tokamak can have a magnificent influence on the performance of photo-electronic multiplier tubes (PMTs), it is necessary to employ magnetic shielding in designing detectors, thus guaranteeing the proper operation of detectors within a strong magnetic field.
Although the PMTs are equipped with magnetic shielding materials by manufacturers, they can only resist the influence of geomagnetic field.
Besides the magnetic shielding and neutron/gamma shielding, neutron detectors should be calibrated before used on the tokamak.
Nine similar detectors were assembled and calibrated in this paper.
The basic idea of processing calibration data is that we should adjust the resolution and the light response function in order to make experiment spectrum and simulation spectrum fit on the recoil proton edge.
A special explication is given to the data processing of neutron calibration, followed by an analysis of its resulting light response function and by comparison with PTB’s results.
Related Results
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction
Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
Pulsed-neutron gamma energy spectroscopy and neutron lifetime measurement systems enable the evaluation of the elemental content, saturation. And recent studies have demonstrated t...
Comparative study of the effect of neutrons emitted from neutron source
241
Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Comparative study of the effect of neutrons emitted from neutron source
241
Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Abstract
Introduction
Cancer is one of the major medical problems threatening human health. Breast cancer ...
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
Porosity is one of the essential parameters in conventional oil and gas reservoir evaluation, as well as plays an important role in the calculation of formation saturation and rese...
Study of coded source neutron imaging based on a compact accelerator
Study of coded source neutron imaging based on a compact accelerator
Compact accelerator based neutron source has lower cost and better flexibility than nuclear reactor. Neutron imaging using such a neutron source has attracted more and more attenti...
Determination of Coal Ash Content by Neutron-Neutron Logging
Determination of Coal Ash Content by Neutron-Neutron Logging
Abstract
The research is aimed at assessing the possibility of studying the ash content of coal seams using neutron-neutron logging in coal exploration wells drilled...
A Novel Gamma-Thermal Neutron Evaluating Gas Saturation Method Using Pulsed Neutron Logging Tool With Dual-CLYC
A Novel Gamma-Thermal Neutron Evaluating Gas Saturation Method Using Pulsed Neutron Logging Tool With Dual-CLYC
In our previous research which has published in 62th SPWLA symposium, a numerical simulation method was proposed which about the double particle detector CLYC (Cs2LiYCl6:CE) to get...
The dependence of neutron/gamma discrimination efficiency on demenstion of EJ-301 scintilator
The dependence of neutron/gamma discrimination efficiency on demenstion of EJ-301 scintilator
This paper presents the results of research on the application of the Monte Carlo simulation method to investigate the dependence of neutron detection efficiency and neutron/gamma ...