Javascript must be enabled to continue!
The dependence of neutron/gamma discrimination efficiency on demenstion of EJ-301 scintilator
View through CrossRef
This paper presents the results of research on the application of the Monte Carlo simulation method to investigate the dependence of neutron detection efficiency and neutron/gamma pulse discrimination capabilities on the size of a detector using the EJ-301 scintillator, supporting the design and development of neutron detectors. We constructed and evaluated eight cylindrical detector models with varying lengths and diameters using the Geant4 toolkit. The simulated detector models consist of a scintillator coupled with a light guide and a photomultiplier tube (PMT). The simulated pulse signals obtained from each model were analyzed to assess neutron/gamma discrimination using the digital charge integration (DCI) method, and neutron detection efficiency was determined at various energy thresholds. The neutron/gamma discrimination results were evaluated based on the Figure of Merit (FoM). The results showed that both neutron/gamma discrimination and neutron detection efficiency are significantly dependent on the detector size, particularly the variations in length and diameter. These findings are crucial for optimizing the design of neutron detectors using organic scintillators like EJ-301 or similar materials, aiming to enhance neutron/gamma discrimination and neutron detection efficiency.
Viet Nam National University Ho Chi Minh City
Title: The dependence of neutron/gamma discrimination efficiency on demenstion of EJ-301 scintilator
Description:
This paper presents the results of research on the application of the Monte Carlo simulation method to investigate the dependence of neutron detection efficiency and neutron/gamma pulse discrimination capabilities on the size of a detector using the EJ-301 scintillator, supporting the design and development of neutron detectors.
We constructed and evaluated eight cylindrical detector models with varying lengths and diameters using the Geant4 toolkit.
The simulated detector models consist of a scintillator coupled with a light guide and a photomultiplier tube (PMT).
The simulated pulse signals obtained from each model were analyzed to assess neutron/gamma discrimination using the digital charge integration (DCI) method, and neutron detection efficiency was determined at various energy thresholds.
The neutron/gamma discrimination results were evaluated based on the Figure of Merit (FoM).
The results showed that both neutron/gamma discrimination and neutron detection efficiency are significantly dependent on the detector size, particularly the variations in length and diameter.
These findings are crucial for optimizing the design of neutron detectors using organic scintillators like EJ-301 or similar materials, aiming to enhance neutron/gamma discrimination and neutron detection efficiency.
Related Results
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
Pulsed-neutron gamma energy spectroscopy and neutron lifetime measurement systems enable the evaluation of the elemental content, saturation. And recent studies have demonstrated t...
Comparative study of the effect of neutrons emitted from neutron source
241
Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Comparative study of the effect of neutrons emitted from neutron source
241
Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Abstract
Introduction
Cancer is one of the major medical problems threatening human health. Breast cancer ...
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
Porosity is one of the essential parameters in conventional oil and gas reservoir evaluation, as well as plays an important role in the calculation of formation saturation and rese...
Determination of Coal Ash Content by Neutron-Neutron Logging
Determination of Coal Ash Content by Neutron-Neutron Logging
Abstract
The research is aimed at assessing the possibility of studying the ash content of coal seams using neutron-neutron logging in coal exploration wells drilled...
North Syrian Mortaria and Other Late Roman Personal and Utility Objects Bearing Inscriptions of Good Luck
North Syrian Mortaria and Other Late Roman Personal and Utility Objects Bearing Inscriptions of Good Luck
<span style="font-size: 11pt; color: black; font-family: 'Times New Roman','serif'">ΠΗΛΙΝΑ ΙΓ&Delta...
Study of coded source neutron imaging based on a compact accelerator
Study of coded source neutron imaging based on a compact accelerator
Compact accelerator based neutron source has lower cost and better flexibility than nuclear reactor. Neutron imaging using such a neutron source has attracted more and more attenti...
A Novel Gamma-Thermal Neutron Evaluating Gas Saturation Method Using Pulsed Neutron Logging Tool With Dual-CLYC
A Novel Gamma-Thermal Neutron Evaluating Gas Saturation Method Using Pulsed Neutron Logging Tool With Dual-CLYC
In our previous research which has published in 62th SPWLA symposium, a numerical simulation method was proposed which about the double particle detector CLYC (Cs2LiYCl6:CE) to get...
Neutron and Photon Dose Rates in a D-T Neutron Generator Facility: MCNP Simulations and Experiments
Neutron and Photon Dose Rates in a D-T Neutron Generator Facility: MCNP Simulations and Experiments
Abstract
The deuterium-tritium neutron generator is a common neutron source for fast neutron activation analysis. The 14.1 MeV neutrons emitted from a deuterium-tritium n...