Inflation balloons for stents are typically sized 1–2mm longer than endovascular stents, yet the effects of the degree of balloon overhang are unknown. In this study, a computational model capable of predicting balloon/stent/artery/plaque interactions and their effects on arterial and plaque stresses was developed to assess the effects of length mismatch and plaque classification on stent expansion characteristics and arterial stresses in diseased arteries. A 16-mm long, 1-mm unexpanded diameter, slotted tube stent was modeled and expanded using contact frictional elements by symmetrically-placed, tapered 17-mm and 18-mm balloons within an artery which contained no plaque to evaluate the effects of stent/balloon size mismatch on arterial stresses. The 18-mm balloon was then also used to expand inside an artery lined with plaque. The plaque was crescent shaped and axisymmetric with a maximum stenosis of 40%. In one model the plaque was primarily cellular, while in another model the plaque was calcified. ANSYS was used to perform the FEA. This model takes into account the multilinear elastic balloon expansion, non-linear plastic stent expansion, and the hyper-elastic arterial and plaque deformations. In this study, endflare was defined by stent diameter at proximal end with respect to stent diameter at the midpoint. Results from this study indicate that without plaque repsent, the maximum arterial stress at balloon contact is approximately proportional to the degree of balloon overhang. A 100% increase in balloon overhang results in a 4% increase in maximum endflare and a 39% change in a peak arterial stress. However, at the end of expansion, which is of the most clinical importance, the increase in max endflare is 2% and the increase in maximum arterial stress is 93% at the balloon point of contact and 45% at the point of contact with the far proximal and distal ends of the stent. When comparing the results of calcified and cellular plaque, a maximum endflare of about 55% was observed for both the calcified and cellular plaque cases during expansion. At the end of expansion the increase in max endflare is 10% for the cellular plaque and 40% of the calcified plaque. The peak equivalent stress seen by the artery was about 100% larger in the cellular case than in the calcified plaque case. This was due to much of the stress being contained within the calcified plaque. The peak stress seen by the plaque was 100% larger in the calcified than in the cellular plaque.
Title: Balloon/Stent Expansion Dynamics in Stenotic Arteries
Description:
Inflation balloons for stents are typically sized 1–2mm longer than endovascular stents, yet the effects of the degree of balloon overhang are unknown.
In this study, a computational model capable of predicting balloon/stent/artery/plaque interactions and their effects on arterial and plaque stresses was developed to assess the effects of length mismatch and plaque classification on stent expansion characteristics and arterial stresses in diseased arteries.
A 16-mm long, 1-mm unexpanded diameter, slotted tube stent was modeled and expanded using contact frictional elements by symmetrically-placed, tapered 17-mm and 18-mm balloons within an artery which contained no plaque to evaluate the effects of stent/balloon size mismatch on arterial stresses.
The 18-mm balloon was then also used to expand inside an artery lined with plaque.
The plaque was crescent shaped and axisymmetric with a maximum stenosis of 40%.
In one model the plaque was primarily cellular, while in another model the plaque was calcified.
ANSYS was used to perform the FEA.
This model takes into account the multilinear elastic balloon expansion, non-linear plastic stent expansion, and the hyper-elastic arterial and plaque deformations.
In this study, endflare was defined by stent diameter at proximal end with respect to stent diameter at the midpoint.
Results from this study indicate that without plaque repsent, the maximum arterial stress at balloon contact is approximately proportional to the degree of balloon overhang.
A 100% increase in balloon overhang results in a 4% increase in maximum endflare and a 39% change in a peak arterial stress.
However, at the end of expansion, which is of the most clinical importance, the increase in max endflare is 2% and the increase in maximum arterial stress is 93% at the balloon point of contact and 45% at the point of contact with the far proximal and distal ends of the stent.
When comparing the results of calcified and cellular plaque, a maximum endflare of about 55% was observed for both the calcified and cellular plaque cases during expansion.
At the end of expansion the increase in max endflare is 10% for the cellular plaque and 40% of the calcified plaque.
The peak equivalent stress seen by the artery was about 100% larger in the cellular case than in the calcified plaque case.
This was due to much of the stress being contained within the calcified plaque.
The peak stress seen by the plaque was 100% larger in the calcified than in the cellular plaque.
Related Results
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract
Introduction
Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
Novel functionalized and patterned surfaces for cardiovascular applications
Novel functionalized and patterned surfaces for cardiovascular applications
Nowadays, cardiovascular diseases are mainly treated by implantation of a metallic or polymeric mesh, called stent, which maintains the artery widely open. This technique shows ver...
Effect of stenotic shapes and arterial wall elasticity on the hemodynamics
Effect of stenotic shapes and arterial wall elasticity on the hemodynamics
The present study employs an arbitrary Lagrangian–Eulerian fluid–structure interaction approach to investigate pulsatile blood flow through a deformable stenosed channel. The flow ...
Minimum stent area, stent expansion and ultrasonic flow ratio post pci: insights from multivessel talent trial
Minimum stent area, stent expansion and ultrasonic flow ratio post pci: insights from multivessel talent trial
Abstract
Background
Ultrasonic flow ratio (UFR) is a novel method for fast computation of fractional flow reserve (FFR) from int...
Fluid and Solid Mechanics in Stented Arteries
Fluid and Solid Mechanics in Stented Arteries
Abstract
Vascular stents are being used in increasing numbers to correct arterial flow limiting disorders. Although data exist on the in vivo performance of these de...
e0517 Forearm arteries with ultrasound for percutaneous coronary procedures
e0517 Forearm arteries with ultrasound for percutaneous coronary procedures
Background
The radial artery has become a widely used approach for coronary angiography and intervention in patients, and the ulnar artery is another approach for...
CLINICAL APPLICATION OF DOMESTIC LONG BIODEGRADABLE POLYMER COATED SIROLIMUS ELUTING STENTS FOR TREATMENT OF LONG CORONARY ARTERY LESIONS
CLINICAL APPLICATION OF DOMESTIC LONG BIODEGRADABLE POLYMER COATED SIROLIMUS ELUTING STENTS FOR TREATMENT OF LONG CORONARY ARTERY LESIONS
Objectives
To evaluate the efficacy and safety of domestic long biodegradable polymer coated sirolimus eluting stents (Excel stent, Shandong JW) for treatment of ...
Abstract 6025: Optimal Stent Deployment. Five Seconds Is Not Enough
Abstract 6025: Optimal Stent Deployment. Five Seconds Is Not Enough
Background
. The risk of thrombosis which had been well described since the advent of stenting, is currently being re-addressed in the era of drug-eluting stents (DES)....