Javascript must be enabled to continue!
Additional balloon aortic valvuloplasty to overcome the difficult removal of a self‐expandable transcatheter aortic valve system due to valve infolding
View through CrossRef
AbstractTranscatheter aortic valve replacement (TAVR) is a well‐established treatment for severe aortic stenosis. Advances in the devices used and operators' technique have reduced the frequency of complications. However, valve infolding is a rare but serious outcome after the implantation of self‐expanding prostheses. We report a case of a successful bailout of a device that was difficult to remove because of valve infolding. TAVR using a 26 mm Evolut PRO+ system (Medtronic) was planned for a 91‐year‐old woman with severe aortic stenosis. After the valve was deployed in a satisfactory position on the second release, the system could not be removed because the nose cone was hooked to the basal frame of the deployed valve. To overcome this situation, an additional balloon was inserted from the contralateral femoral side and inflated, and we extracted the system successfully by pulling out the device while simultaneously deflating the balloon. Postoperative computed tomography revealed valve infolding, which was considered to cause the difficulty in system removal. Infoldings of self‐expandable prostheses should be considered when faced with difficulty in removing the catheter system, and the method elucidated in this case report can be effective to manage it.
Title: Additional balloon aortic valvuloplasty to overcome the difficult removal of a self‐expandable transcatheter aortic valve system due to valve infolding
Description:
AbstractTranscatheter aortic valve replacement (TAVR) is a well‐established treatment for severe aortic stenosis.
Advances in the devices used and operators' technique have reduced the frequency of complications.
However, valve infolding is a rare but serious outcome after the implantation of self‐expanding prostheses.
We report a case of a successful bailout of a device that was difficult to remove because of valve infolding.
TAVR using a 26 mm Evolut PRO+ system (Medtronic) was planned for a 91‐year‐old woman with severe aortic stenosis.
After the valve was deployed in a satisfactory position on the second release, the system could not be removed because the nose cone was hooked to the basal frame of the deployed valve.
To overcome this situation, an additional balloon was inserted from the contralateral femoral side and inflated, and we extracted the system successfully by pulling out the device while simultaneously deflating the balloon.
Postoperative computed tomography revealed valve infolding, which was considered to cause the difficulty in system removal.
Infoldings of self‐expandable prostheses should be considered when faced with difficulty in removing the catheter system, and the method elucidated in this case report can be effective to manage it.
Related Results
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Valvuloplasty Balloon Catheter Sizing Approach for Calcified Aortic Valve with Different Annulus Ratios
Valvuloplasty Balloon Catheter Sizing Approach for Calcified Aortic Valve with Different Annulus Ratios
Transcatheter aortic valve implantation (TAVI) is re- garded as the option of preference minimally invasive intervention to treat high-risk patients with aortic steno- sis, whic...
Incidence, predictors and outcomes of Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR): a systematic review and meta-analysis
Incidence, predictors and outcomes of Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR): a systematic review and meta-analysis
Abstract
Background
Surgical aortic valve replacement has been the treatment of choice for patients with aortic valve disease be...
Predilatation Prior to Transcatheter Aortic Valve Implantation: Is it Still a Prerequisite?
Predilatation Prior to Transcatheter Aortic Valve Implantation: Is it Still a Prerequisite?
Predilatation has been historically considered a mandatory step before transcatheter aortic valve implantation (TAVI) since it facilitates valve crossing and prosthesis delivery, e...
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
Objectives
To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia.
...
Valve-Sparing Aortic Root Replacement by Congenital Heart Surgeons: A Single Center Experience.
Valve-Sparing Aortic Root Replacement by Congenital Heart Surgeons: A Single Center Experience.
Background Aortic root dilatation and aortic insufficiency can
occur in patients with prior conotruncal defect surgery, the Ross
procedure, and connective tissue disease (CTD). Val...
Prior surgical mitral commissurotomy and echocardiographic score influence in mitral balloon valvuloplasty. Immediate post procedure results
Prior surgical mitral commissurotomy and echocardiographic score influence in mitral balloon valvuloplasty. Immediate post procedure results
Abstract
Introduction
Percutaneous mitral balloon valvuloplasty is effective in mitral stenosis. Objectives: to evaluate prior m...
Perspective Chapter: Transcatheter Interventions in the Management of Aortic Valve Stenosis
Perspective Chapter: Transcatheter Interventions in the Management of Aortic Valve Stenosis
Transcatheter interventions that are useful in the management of valvar aortic stenosis will be reviewed. This chapter focuses on congenital aortic valve stenosis. The procedure of...