Javascript must be enabled to continue!
Valvuloplasty Balloon Catheter Sizing Approach for Calcified Aortic Valve with Different Annulus Ratios
View through CrossRef
Transcatheter aortic valve implantation (TAVI) is re- garded as the option of preference minimally invasive intervention to treat high-risk patients with aortic steno- sis, which is a common heart valve disease charac- terized by the narrowing of the valve opening due to the thickening of the valve leaflets. During TAVI, a prosthetic aortic valve, replacing the diseased native valve with its function, is inserted and expanded by a balloon catheter if it is a balloon-expandable device. As a result, the correct size of the prosthetic device is vital due to its association with potential complications such as paravalvular regurgitation and aortic annulus rupture [1]. Pre-operative annulus size measurement based on imaging techniques is commonly applied be- fore TAVI procedure including transthoracic echocar- diography, transesophageal echocardiography and multi- detector computed tomography [2], [3]. However, these techniques face two major limitations: heavy dependence on the operator’s experience and the influence of the optimum instant in the cardiac cycle for evaluation. In addition, the potential changes in the annular geometry caused by balloon aortic valvuloplasty, which uses a balloon catheter to dilate the calcified aortic leaflets as a bridge treatment to TAVI, are not considered. There- fore, intraoperative assessments based on valvuloplasty balloon catheters were introduced, which measure the annulus size by the balloon when it is inflated for dilatation [4]. They do, however, only provide limited compatibility for a limited number of devices. This study proposes an intra-operative method for mea- suring the aortic annulus that account for compliance and elliptical geometries using balloon internal pressure and volume data. The valvuloplasty balloon catheter from a commercially available source was used to obtain the intra-balloon pressure-volume curves by an inflation device. A characterized analytical model and a numeri- cal model for balloon free-inflation were used to develop a sizing algorithm for estimating annulus dimensions.
The Hamlyn Centre, Imperial College London London, UK
Title: Valvuloplasty Balloon Catheter Sizing Approach for Calcified Aortic Valve with Different Annulus Ratios
Description:
Transcatheter aortic valve implantation (TAVI) is re- garded as the option of preference minimally invasive intervention to treat high-risk patients with aortic steno- sis, which is a common heart valve disease charac- terized by the narrowing of the valve opening due to the thickening of the valve leaflets.
During TAVI, a prosthetic aortic valve, replacing the diseased native valve with its function, is inserted and expanded by a balloon catheter if it is a balloon-expandable device.
As a result, the correct size of the prosthetic device is vital due to its association with potential complications such as paravalvular regurgitation and aortic annulus rupture [1].
Pre-operative annulus size measurement based on imaging techniques is commonly applied be- fore TAVI procedure including transthoracic echocar- diography, transesophageal echocardiography and multi- detector computed tomography [2], [3].
However, these techniques face two major limitations: heavy dependence on the operator’s experience and the influence of the optimum instant in the cardiac cycle for evaluation.
In addition, the potential changes in the annular geometry caused by balloon aortic valvuloplasty, which uses a balloon catheter to dilate the calcified aortic leaflets as a bridge treatment to TAVI, are not considered.
There- fore, intraoperative assessments based on valvuloplasty balloon catheters were introduced, which measure the annulus size by the balloon when it is inflated for dilatation [4].
They do, however, only provide limited compatibility for a limited number of devices.
This study proposes an intra-operative method for mea- suring the aortic annulus that account for compliance and elliptical geometries using balloon internal pressure and volume data.
The valvuloplasty balloon catheter from a commercially available source was used to obtain the intra-balloon pressure-volume curves by an inflation device.
A characterized analytical model and a numeri- cal model for balloon free-inflation were used to develop a sizing algorithm for estimating annulus dimensions.
Related Results
P1718 Multi-modal imaging characterization of contained aortic subannular rupture after transcatheter aortic valve implantation
P1718 Multi-modal imaging characterization of contained aortic subannular rupture after transcatheter aortic valve implantation
Abstract
INTRODUCTION
Aortic annular rupture is a potentially catastrophic complication after transcatheter aortic valve implant...
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
Objectives
To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia.
...
Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Transcatheter aortic valve replacement is a well-established treatment for high-surgical-risk patients with severe aortic disease, providing a less invasive alternative to traditio...
Small Aortic Annulus: Aortic Allografts vs Perceval S
Small Aortic Annulus: Aortic Allografts vs Perceval S
Цель. Оценить и сравнить гемодинамические показатели и изменение качества жизни после имплантации протезов Perceval S и аортальных аллографтов, а также частоту и спектр осложнений ...
Aortic root wrapped procedure
Aortic root wrapped procedure
Objective
To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia.
...
The Critical Role of Presettable and Expandable Artificial Surgical Valves in the Lifetime Management of Valvular Heart Disease
The Critical Role of Presettable and Expandable Artificial Surgical Valves in the Lifetime Management of Valvular Heart Disease
With the trend of younger patients undergoing surgical valve replacement and increased life expectancy, how to account for subsequent therapies during the initial valve replacement...
Temporal trends in the incidence and mortality of calcified arotic valve disease in the nordic countries over the past 30 years
Temporal trends in the incidence and mortality of calcified arotic valve disease in the nordic countries over the past 30 years
Abstract
Introduction
Calcified aortic valve is imposes significant burden due to the associated morbidity and mortality....
Predicting the Ideal Valve Size During Aortic Valve Replacement with Rapid Deployement Bioprosthetic Valves. Is Intraoperative Transesophageal Echocardiogram Reliable?
Predicting the Ideal Valve Size During Aortic Valve Replacement with Rapid Deployement Bioprosthetic Valves. Is Intraoperative Transesophageal Echocardiogram Reliable?
Objective: To describe experience with using intraoperative
Transesophageal Echocardiography to reliably predict the size of the
rapid deployment prosthetic valve by measuring the ...