Javascript must be enabled to continue!
Incidence, predictors and outcomes of Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR): a systematic review and meta-analysis
View through CrossRef
Abstract
Background
Surgical aortic valve replacement has been the treatment of choice for patients with aortic valve disease before the arrival of transcatheter aortic valve replacement (TAVI), although limited by degeneration of the bioprosthesis. “Redo” intervention itself is burdened by high risk of complications and valve-in-valve (ViV) TAVI could be a valid strategy of redo for patients with comorbidities. The aim of this meta-analysis is to give an overview of the state of the art of ViV TAVI in high-risk patients, analyzing efficacy, safety, intra-hospital outcomes and 1-year outcomes and assess predictors of survival at short and mid-term follow up.
Methods
Two independent reviewers screened all studies investigating patients undergoing ViV TAVI. PubMed database was searched for reports published in English according to the following highly sensitive strategy: (Transcatheter[All Fields] AND “aortic”[All Fields]) AND valve-in-valve[All Fields] AND “implantation”[All Fields] NOT (review[pt] OR editorial[pt] OR letter[pt])AND “humans”[MeSH Terms]). Mortality at 30 days and at 1 year were the primary end point, while procedural and short-term outcomes and echocardiographic parameters at hospital discharge were the secondary end points.
Results
Of 286 studies identified, 26 articles were included, with a total of 1448 patients. Median age was 78.8 years, 57.7% of the patients were male. Median STS-predicted risk of mortality was 9.4% while median Logistic EuroSCORE was 31.3%. Median age of bioprosthesis was 10 years with 84.6% of stented valves. Stenosis (45%), followed by regurgitation (31%) and mixed defects (21%) were the causes of prosthesis failure. Diameter of the degenerated valve was ≤21 mm in 25.4%, 22–25 mm in 55% and >25mm in 11.7% of the patients. Transfemoral approach was preferred (76%), with a prevalence of balloon expandable valve (73.3%). Mean post procedural gradient was 16.7±0.8 mmHg. Mean follow up was 376 days. Overall and cardiovascular mortality at 30 days was 6.5% and 5.5% respectively, while at 1 year it was 14.5% and 8.9% respectively. Regarding short-term outcomes, overall bleeding (10.4%), pacemaker implantation (9.4%) and vascular complications (8.3%) were the most common peri-procedural complications, while stroke (2.3%), myocardial infarction (2.7%) and coronary obstruction (2.8%) were less frequent. At meta-regression analysis study year (p<0.001), Logistic Euroscore (p<0.01) and valve diameter ≤21 mm (p<0.05) at 30 days, and stenosis as reason for failure (p=0.05) at 1 year were identified as possible predictors of survival.
Conclusions
Percutaneous valve-in-valve aortic valve implantation offers a valid strategy to treat high risk patients with a degenerative bioprosthesis. Short and mid-term outcomes are substantially superimposable to those of TAVI, except for coronary obstruction which appears more frequent. Future studies are needed to find predictors of long- term survival and outcomes in lower risk patients.
Outcome of VIV TAVI
Funding Acknowledgement
Type of funding source: None
Oxford University Press (OUP)
Title: Incidence, predictors and outcomes of Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR): a systematic review and meta-analysis
Description:
Abstract
Background
Surgical aortic valve replacement has been the treatment of choice for patients with aortic valve disease before the arrival of transcatheter aortic valve replacement (TAVI), although limited by degeneration of the bioprosthesis.
“Redo” intervention itself is burdened by high risk of complications and valve-in-valve (ViV) TAVI could be a valid strategy of redo for patients with comorbidities.
The aim of this meta-analysis is to give an overview of the state of the art of ViV TAVI in high-risk patients, analyzing efficacy, safety, intra-hospital outcomes and 1-year outcomes and assess predictors of survival at short and mid-term follow up.
Methods
Two independent reviewers screened all studies investigating patients undergoing ViV TAVI.
PubMed database was searched for reports published in English according to the following highly sensitive strategy: (Transcatheter[All Fields] AND “aortic”[All Fields]) AND valve-in-valve[All Fields] AND “implantation”[All Fields] NOT (review[pt] OR editorial[pt] OR letter[pt])AND “humans”[MeSH Terms]).
Mortality at 30 days and at 1 year were the primary end point, while procedural and short-term outcomes and echocardiographic parameters at hospital discharge were the secondary end points.
Results
Of 286 studies identified, 26 articles were included, with a total of 1448 patients.
Median age was 78.
8 years, 57.
7% of the patients were male.
Median STS-predicted risk of mortality was 9.
4% while median Logistic EuroSCORE was 31.
3%.
Median age of bioprosthesis was 10 years with 84.
6% of stented valves.
Stenosis (45%), followed by regurgitation (31%) and mixed defects (21%) were the causes of prosthesis failure.
Diameter of the degenerated valve was ≤21 mm in 25.
4%, 22–25 mm in 55% and >25mm in 11.
7% of the patients.
Transfemoral approach was preferred (76%), with a prevalence of balloon expandable valve (73.
3%).
Mean post procedural gradient was 16.
7±0.
8 mmHg.
Mean follow up was 376 days.
Overall and cardiovascular mortality at 30 days was 6.
5% and 5.
5% respectively, while at 1 year it was 14.
5% and 8.
9% respectively.
Regarding short-term outcomes, overall bleeding (10.
4%), pacemaker implantation (9.
4%) and vascular complications (8.
3%) were the most common peri-procedural complications, while stroke (2.
3%), myocardial infarction (2.
7%) and coronary obstruction (2.
8%) were less frequent.
At meta-regression analysis study year (p<0.
001), Logistic Euroscore (p<0.
01) and valve diameter ≤21 mm (p<0.
05) at 30 days, and stenosis as reason for failure (p=0.
05) at 1 year were identified as possible predictors of survival.
Conclusions
Percutaneous valve-in-valve aortic valve implantation offers a valid strategy to treat high risk patients with a degenerative bioprosthesis.
Short and mid-term outcomes are substantially superimposable to those of TAVI, except for coronary obstruction which appears more frequent.
Future studies are needed to find predictors of long- term survival and outcomes in lower risk patients.
Outcome of VIV TAVI
Funding Acknowledgement
Type of funding source: None.
Related Results
Early evolution of cardiac damage staging following transcatheter aortic valve replacement: prevalence, clinical patterns and prognostic significance
Early evolution of cardiac damage staging following transcatheter aortic valve replacement: prevalence, clinical patterns and prognostic significance
Abstract
Funding Acknowledgements
Type of funding sources: None.
Background
...
Abstract 4363465: Differential Outcomes of TAVR With and Without Percutaneous Coronary Intervention During Same Hospitalization
Abstract 4363465: Differential Outcomes of TAVR With and Without Percutaneous Coronary Intervention During Same Hospitalization
Background:
Transcatheter aortic valve replacement (TAVR) has emerged as a transformative, minimally invasive alternative to surgical aortic valve replacement f...
Use of a wearable patch sensor for continuous activity and posture tracking to assess risk of early infection after transcatheter aortic valve replacement
Use of a wearable patch sensor for continuous activity and posture tracking to assess risk of early infection after transcatheter aortic valve replacement
Abstract
Background
Early infections after transcatheter aortic valve replacement (TAVR) represent one of the most common risk f...
Pacemaker implantation after balloon- or self-expandable transcatheter aortic valve replacement in patients with aortic stenosis
Pacemaker implantation after balloon- or self-expandable transcatheter aortic valve replacement in patients with aortic stenosis
Abstract
Background
The incidence of conduction abnormalities requiring permanent pacemaker implantation (PPI) after transcathet...
Pacemaker Implantation After Balloon‐ or Self‐Expandable Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis
Pacemaker Implantation After Balloon‐ or Self‐Expandable Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis
Background
The incidence of conduction abnormalities requiring permanent pacemaker implantation (
PPI
) after transcatheter a...
Incidence, Outcomes and Predictors of Aortic Regurgitation After Transcatheter Aortic Valve Replacement in Al Azhar University Hospitals and National Heart Institute, Egypt
Incidence, Outcomes and Predictors of Aortic Regurgitation After Transcatheter Aortic Valve Replacement in Al Azhar University Hospitals and National Heart Institute, Egypt
Background: Aortic regurgitation (AR), which has ill-defined predictors and an unknown long-term influence on outcomes, is a significant transcatheter aortic valve replacement (TAV...
Predictors of ventricular pacing burden after permanent pacemaker implantation following transcatheter aortic valve replacement
Predictors of ventricular pacing burden after permanent pacemaker implantation following transcatheter aortic valve replacement
AbstractBackgroundIn the era of an expanding use of transcatheter aortic valve replacement (TAVR), conduction disturbances and the requirement for permanent pacemaker (PPM) implant...
Outcomes of permanent pacemaker implantation following transcatheter aortic valve replacement
Outcomes of permanent pacemaker implantation following transcatheter aortic valve replacement
Abstract
Background
Conduction abnormalities leading to permanent pacemaker (PPM) implantation are common complications followin...

