Javascript must be enabled to continue!
Automatic Load Sharing of Transformer
View through CrossRef
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which leads to the judgment of the transformer installation which leads to disruption of the power supply to the load. It takes a lot of time to repair and involves a lot of costs. This project deals with transformer protection under conditions of overcrowding. The transformer could be protected by reducing the additional the transformer's load by connecting and using another transformer in conjunction the primary transformer using a microcontroller and a switch relay. The load on the first transformer is compared to the reference value by the Arduino. When the load exceeds the reference value, the slave transformer is automatically attached to the first transformer and the extra load is shared. Therefore, the number of transformers works well under conditions of overcrowding and damage could be prevented. In this project, slave transformers share the master transformer's duty in the event of overcrowding and overheating. Sensor circuit with Arduino, current transformer, and other components is designed to collect data from the master transformer, and if it is determined to be overloaded, the slave transformer is immediately attached to the master transformer and the load is shared. The Arduino keeps track of the transformer's current volume and displays it. If loads are introduced to the current transformer's second side in the second side riser. As the current volume exceeds the estimated current value of the transformer, so the microcontroller sends a travel signal to the relay, thus opening the slave transformer. Initially when we open the load, it will be shared by the first transformer. Once the load on the first transformer has been raised above its maximum capacity, the standby transformer will automatically share the load.
Title: Automatic Load Sharing of Transformer
Description:
Transformer plays a major role in the power system.
It works 24 hours a day and provides power to the load.
The transformer is excessive full, its windings are overheated which leads to the judgment of the transformer installation which leads to disruption of the power supply to the load.
It takes a lot of time to repair and involves a lot of costs.
This project deals with transformer protection under conditions of overcrowding.
The transformer could be protected by reducing the additional the transformer's load by connecting and using another transformer in conjunction the primary transformer using a microcontroller and a switch relay.
The load on the first transformer is compared to the reference value by the Arduino.
When the load exceeds the reference value, the slave transformer is automatically attached to the first transformer and the extra load is shared.
Therefore, the number of transformers works well under conditions of overcrowding and damage could be prevented.
In this project, slave transformers share the master transformer's duty in the event of overcrowding and overheating.
Sensor circuit with Arduino, current transformer, and other components is designed to collect data from the master transformer, and if it is determined to be overloaded, the slave transformer is immediately attached to the master transformer and the load is shared.
The Arduino keeps track of the transformer's current volume and displays it.
If loads are introduced to the current transformer's second side in the second side riser.
As the current volume exceeds the estimated current value of the transformer, so the microcontroller sends a travel signal to the relay, thus opening the slave transformer.
Initially when we open the load, it will be shared by the first transformer.
Once the load on the first transformer has been raised above its maximum capacity, the standby transformer will automatically share the load.
Related Results
Crane Load Moment System For Offshore Crane Operations
Crane Load Moment System For Offshore Crane Operations
Abstract
History has shown that dependency upon the crane operator to monitor loads and boom angle or load radius do not allow the margin necessary to perform the...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...
Pemodelan Kurva Pembebanan Transformator Distribusi Berdasarkan Variasi Penetrasi PLTS Atap
Pemodelan Kurva Pembebanan Transformator Distribusi Berdasarkan Variasi Penetrasi PLTS Atap
Transformers are considered important equipment in the power distribution system. Determining the state of the distribution network loading curve a network model to analyze the imp...
Simulation modeling study on short circuit ability of distribution transformer
Simulation modeling study on short circuit ability of distribution transformer
Abstract
Under short circuit condition, the oil immersed distribution transformer will endure combined electro-thermal stress, eventually lead to the mechanical dama...
Analysis of Transformer Service Life Prediction at Traction Substation Cipete Raya MRT Jakarta Based on Temperature and Load Using Linear Regression Method.
Analysis of Transformer Service Life Prediction at Traction Substation Cipete Raya MRT Jakarta Based on Temperature and Load Using Linear Regression Method.
PT Mass Rapid Transit Jakarta operates a mass transportation system from Lebak Bulus Station to Bundaran HI. One of the traction substations is located in Cipete Raya, with a volta...
DESIGN AND IMPLEMENTATION OF AUTOMATIC TRANSFORMER OVERLOAD PROTECTION SYSTEM
DESIGN AND IMPLEMENTATION OF AUTOMATIC TRANSFORMER OVERLOAD PROTECTION SYSTEM
Load sharing provides sufficient protection to distribution transformer under overloaded conditions. Due to overload on transformer, the efficiency drops and windings get overheate...
The impact of employees’ relationships on tacit knowledge sharing
The impact of employees’ relationships on tacit knowledge sharing
Purpose– This paper aims to study the impact of individual relationships on tacit knowledge sharing in the company setting of compulsory bond, expressive bond, instrumental bond an...


