Simulation modeling study on short circuit ability of distribution transformer

View through CrossRef
Abstract Under short circuit condition, the oil immersed distribution transformer will endure combined electro-thermal stress, eventually lead to the mechanical damage of the inner winding of distribution transformer, therefore it is necessary to study the short circuit ability of the oil immersed distribution transformer. In this paper, the typical current waveform of the distribution transformer under the short-circuit condition is analyzed theoretically. The short circuit fault simulation model of distribution transformer is built on the MATLAB/Simulink simulation platform, the short circuit waveform of the single phase, double phase and three phase short circuit is obtained. Further on the ANSYS simulation platform, three dimensional solid modeling of the three-phase five column transformer is carried out, the harmonic and transient field are applied to analyze the magnetic field distribution of the key components in distribution transformer under the short circuit condition, the internal cause of large short-circuit force in the winding of the distribution transformer under the short circuit condition is analyzed to certain extent. The results of the modeling and simulation show that the three phase short circuit current is larger than the single-phase and bi-phase short circuit current. Its value is 1.45 times the normal running current, which is the gradual damping asymmetrical short-circuit current. Magnetic induction intensity is in-homogeneous in the circumferential direction of the core column, and the degree of in-homogeneity varies along height. The magnetic density distribution under the short circuit condition is more than 6 times as much as the the normal condition. From the point of view of simulation modeling, short circuit ability of the oil immersed distribution transformer is analyzed, distribution characteristics of short circuit current and magnetic field of oil immersed distribution transformer under short circuit condition have been obtained, the theoretical reference value of the state characteristics and protection measures of oil immersed distribution transformer under the overload condition can be provided.
Title: Simulation modeling study on short circuit ability of distribution transformer
Description:
Abstract Under short circuit condition, the oil immersed distribution transformer will endure combined electro-thermal stress, eventually lead to the mechanical damage of the inner winding of distribution transformer, therefore it is necessary to study the short circuit ability of the oil immersed distribution transformer.
In this paper, the typical current waveform of the distribution transformer under the short-circuit condition is analyzed theoretically.
The short circuit fault simulation model of distribution transformer is built on the MATLAB/Simulink simulation platform, the short circuit waveform of the single phase, double phase and three phase short circuit is obtained.
Further on the ANSYS simulation platform, three dimensional solid modeling of the three-phase five column transformer is carried out, the harmonic and transient field are applied to analyze the magnetic field distribution of the key components in distribution transformer under the short circuit condition, the internal cause of large short-circuit force in the winding of the distribution transformer under the short circuit condition is analyzed to certain extent.
The results of the modeling and simulation show that the three phase short circuit current is larger than the single-phase and bi-phase short circuit current.
Its value is 1.
45 times the normal running current, which is the gradual damping asymmetrical short-circuit current.
Magnetic induction intensity is in-homogeneous in the circumferential direction of the core column, and the degree of in-homogeneity varies along height.
The magnetic density distribution under the short circuit condition is more than 6 times as much as the the normal condition.
From the point of view of simulation modeling, short circuit ability of the oil immersed distribution transformer is analyzed, distribution characteristics of short circuit current and magnetic field of oil immersed distribution transformer under short circuit condition have been obtained, the theoretical reference value of the state characteristics and protection measures of oil immersed distribution transformer under the overload condition can be provided.

Related Results

Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
Approaching the Processes in the Generator Circuit Breaker at Disconnection through Sustainability Concepts
Approaching the Processes in the Generator Circuit Breaker at Disconnection through Sustainability Concepts
Nowadays, the electric connection circuits of power plants (based on fossil fuels as well as renewable sources) entail generator circuit-breakers (GCBs) at the generator terminals,...
High frequency modeling of power transformers under transients
High frequency modeling of power transformers under transients
This thesis presents the results related to high frequency modeling of power transformers. First, a 25kVA distribution transformer under lightning surges is tested in the laborator...
Study of Transformer Lifetime Due to Loading Process on 20 KV Distribution Line
Study of Transformer Lifetime Due to Loading Process on 20 KV Distribution Line
Power transformer is very important in electric power system due to its function to raise or lower the voltage according to its designation. On the power side, the power transforme...
CALCULATION OF POWER TRANSFORMER INDUCTANCE MATRIX
CALCULATION OF POWER TRANSFORMER INDUCTANCE MATRIX
Practical calculations of electric equipment and electric networks are performed using equivalent circuits. Without taking into account saturation phenomena, electromagnetic proces...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...
A Study of Superconducting Transformer with Short-Circuit Current Limitation
A Study of Superconducting Transformer with Short-Circuit Current Limitation
The paper presents physico-mathematical models for analyzing transient processes in electrical networks having transformers with a high temperature superconducting winding. One of ...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...