A Study of Superconducting Transformer with Short-Circuit Current Limitation
View through CrossRef
The paper presents physico-mathematical models for analyzing transient processes in electrical networks having transformers with a high temperature superconducting winding. One of the main purposes of the study is the investigation of the short circuit current limitation process with the use of a transformer with a high temperature superconducting winding, that allows the combination of two series-connected elements, transformer and reactor, in one device. The efficiency of this method for short circuit current limitation is provided by the fact that the critical value of superconducting winding temperature is exceeded under short circuit current flowing, then it passes into the normal state with a high impedance winding, thus limiting a short circuit current. It is important to know the moment when superconducting material passes into the normal state with the loss of superconductivity. For this purpose, the program for calculating the quantity of heat under short circuit current flowing before its interruption was developed. If a 40 MVA transformer with a high temperature superconducting winding is considered, short circuit should be cleared after 100 ms without transformer disconnection. It is proposed to use a hybrid winding in addition to the main winding for short circuit current limitation. Conducted investigations showed that the return of a winding into the superconducting state depends primarily on the ratio between a short circuit current and a rated load current. This represents the criterion for returning or not returning into the superconducting state for transformer windings.
Institute of Advanced Engineering and Science
Title: A Study of Superconducting Transformer with Short-Circuit Current Limitation
Description:
The paper presents physico-mathematical models for analyzing transient processes in electrical networks having transformers with a high temperature superconducting winding.
One of the main purposes of the study is the investigation of the short circuit current limitation process with the use of a transformer with a high temperature superconducting winding, that allows the combination of two series-connected elements, transformer and reactor, in one device.
The efficiency of this method for short circuit current limitation is provided by the fact that the critical value of superconducting winding temperature is exceeded under short circuit current flowing, then it passes into the normal state with a high impedance winding, thus limiting a short circuit current.
It is important to know the moment when superconducting material passes into the normal state with the loss of superconductivity.
For this purpose, the program for calculating the quantity of heat under short circuit current flowing before its interruption was developed.
If a 40 MVA transformer with a high temperature superconducting winding is considered, short circuit should be cleared after 100 ms without transformer disconnection.
It is proposed to use a hybrid winding in addition to the main winding for short circuit current limitation.
Conducted investigations showed that the return of a winding into the superconducting state depends primarily on the ratio between a short circuit current and a rated load current.
This represents the criterion for returning or not returning into the superconducting state for transformer windings.
Related Results
Simulation modeling study on short circuit ability of distribution transformer
Simulation modeling study on short circuit ability of distribution transformer
Abstract
Under short circuit condition, the oil immersed distribution transformer will endure combined electro-thermal stress, eventually lead to the mechanical dama...
Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
Approaching the Processes in the Generator Circuit Breaker at Disconnection through Sustainability Concepts
Approaching the Processes in the Generator Circuit Breaker at Disconnection through Sustainability Concepts
Nowadays, the electric connection circuits of power plants (based on fossil fuels as well as renewable sources) entail generator circuit-breakers (GCBs) at the generator terminals,...
Vortex pattern in three-dimensional mesoscopic superconducting rings
Vortex pattern in three-dimensional mesoscopic superconducting rings
Vortex structures in a mesoscopic a superconducting ring, which is in the magnetic field generated by a circular electric current, are investigated based on the phenomenological Gi...
High frequency modeling of power transformers under transients
High frequency modeling of power transformers under transients
This thesis presents the results related to high frequency modeling of power transformers. First, a 25kVA distribution transformer under lightning surges is tested in the laborator...
CALCULATION OF POWER TRANSFORMER INDUCTANCE MATRIX
CALCULATION OF POWER TRANSFORMER INDUCTANCE MATRIX
Practical calculations of electric equipment and electric networks are performed using equivalent circuits. Without taking into account saturation phenomena, electromagnetic proces...
Study of Transformer Lifetime Due to Loading Process on 20 KV Distribution Line
Study of Transformer Lifetime Due to Loading Process on 20 KV Distribution Line
Power transformer is very important in electric power system due to its function to raise or lower the voltage according to its designation. On the power side, the power transforme...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...