Calibration of a Virtual Instrument for Power Quality Monitoring
View through CrossRef
The paper describes a virtual instrument for power quality monitoring based on NI LabVIEW™ platform and simultaneous measurements of electrical voltages and currents. The virtual power quality analyzer is realized by using National Instruments 9225 and 9227 modules for voltage and current measurements, respectively, NI cDAQ 9174, 4 slot USB chassis and a PC. The created virtual instrument measures power quality characteristics: power frequency, voltage variations, magnitude of rapid voltage changes, flicker severity, voltage unbalance, total harmonic distortion, as well as the elements of voltage dips, short interruptions, and long interruptions defined in the standard EN 50160 for voltage characteristics of supplied electricity. The measurement is according to the general guide on harmonics and interharmonics measurements IEC 61000-4-7. The calibration and verification of the power quality analyzer is a complex task and it is performed by using the laboratory calibrator FLUKE 5500A. The results of calibration and verification of the developed virtual instrument, as well as the results of power quality measurements near different lightning technologies are presented
Title: Calibration of a Virtual Instrument for Power Quality Monitoring
Description:
The paper describes a virtual instrument for power quality monitoring based on NI LabVIEW™ platform and simultaneous measurements of electrical voltages and currents.
The virtual power quality analyzer is realized by using National Instruments 9225 and 9227 modules for voltage and current measurements, respectively, NI cDAQ 9174, 4 slot USB chassis and a PC.
The created virtual instrument measures power quality characteristics: power frequency, voltage variations, magnitude of rapid voltage changes, flicker severity, voltage unbalance, total harmonic distortion, as well as the elements of voltage dips, short interruptions, and long interruptions defined in the standard EN 50160 for voltage characteristics of supplied electricity.
The measurement is according to the general guide on harmonics and interharmonics measurements IEC 61000-4-7.
The calibration and verification of the power quality analyzer is a complex task and it is performed by using the laboratory calibrator FLUKE 5500A.
The results of calibration and verification of the developed virtual instrument, as well as the results of power quality measurements near different lightning technologies are presented.
Related Results
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction
Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
To simplify the cross-calibration process and improve calibration frequency and accuracy, this paper proposes a cross-calibration method for the multispectral remote sensor Multi-S...
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
EFEKTIFITAS PELATIHAN LABORATORIUM VIRTUAL SEBAGAI MEDIA PEMBELAJARAN BAGI GURU KIMIA
EFEKTIFITAS PELATIHAN LABORATORIUM VIRTUAL SEBAGAI MEDIA PEMBELAJARAN BAGI GURU KIMIA
EFFECTIVITY OF VIRTUAL LABORATORY TRAINING AS A LEARNING MEDIA FOR CHEMISTRY TEACHERSAchmad Lutfi, SukarminUniversitas Negeri Surabaya, Indonesia achmadlutfi@unesa.ac.idAbstractThe...
Applicability of self-consistency calibration method for polarimetric cloud radars
Applicability of self-consistency calibration method for polarimetric cloud radars
Cloud radars are powerful tools for investigating cloud formation, radiative processes, and cloud microphysics. In recent years, polarimetric cloud radars have become increasingly ...
Binocular vision calibration method for a long-wavelength infrared camera and a visible spectrum camera with different resolutions
Binocular vision calibration method for a long-wavelength infrared camera and a visible spectrum camera with different resolutions
We present a calibration plate for the binocular vision system, which is composed of a long-wavelength infrared camera and a visible spectrum camera with different resolutions. The...
Impact of calibration frequency on accuracy of critical biochemical analytes: Review article
Impact of calibration frequency on accuracy of critical biochemical analytes: Review article
Calibration of laboratory instruments is a cornerstone of analytical quality assurance in clinical biochemistry. In tertiary-care hospital laboratories, where decisions are frequen...