Javascript must be enabled to continue!
Assessment of Immediate, Short- and Long-Term Outcomes After Transcatheter Perimembranous Ventricular Septal Defect (PM VSD) Closure by KONAR-MF Occluder Device
View through CrossRef
Background: Perimembranous ventricular septal defect (PM VSD) is the most prevalent congenital heart defect, traditionally managed by surgical closure with associated morbidity. Objective: This study aimed to evaluate the immediate, short-, and one-year clinical outcomes of transcatheter PM VSD closure using the KONAR-MF occluder device in children, focusing on closure rates, valvular function, and rhythm disturbances. Methods: A prospective, single-arm cohort study was conducted at the National Institute of Cardiovascular Diseases (NICVD), Karachi, enrolling 42 patients aged <18 years with PM VSD suitable for device closure. Patients with right coronary cusp prolapse, pulmonary hypertension, or multiple congenital defects requiring surgery were excluded. Echocardiography, angiography, and electrocardiography were performed at baseline, post-procedure, and at 1, 3, 6, and 12 months. The study received ethical approval and adhered to the Declaration of Helsinki. Descriptive analysis was conducted using SPSS v26. Results: The mean age was 9.6 ± 5 years and weight 23.6 ± 12.4 kg. Immediate closure was achieved in 97.6%, sustained in 95.2% at 12 months. No cases of AV block, haemolysis, or significant arrhythmias were observed. Mild, non-progressive aortic regurgitation occurred in one patient (2.4%); tricuspid regurgitation improved over time. One unrelated death occurred at 12 months. Valvular function and ECG remained stable with no statistically significant deterioration (p > 0.05). Conclusion: Transcatheter PM VSD closure using the KONAR-MF occluder is a safe and effective alternative to surgery in selected pediatric patients, offering high closure rates and a low complication profile, supporting its clinical applicability in structural heart disease management.
Title: Assessment of Immediate, Short- and Long-Term Outcomes After Transcatheter Perimembranous Ventricular Septal Defect (PM VSD) Closure by KONAR-MF Occluder Device
Description:
Background: Perimembranous ventricular septal defect (PM VSD) is the most prevalent congenital heart defect, traditionally managed by surgical closure with associated morbidity.
Objective: This study aimed to evaluate the immediate, short-, and one-year clinical outcomes of transcatheter PM VSD closure using the KONAR-MF occluder device in children, focusing on closure rates, valvular function, and rhythm disturbances.
Methods: A prospective, single-arm cohort study was conducted at the National Institute of Cardiovascular Diseases (NICVD), Karachi, enrolling 42 patients aged <18 years with PM VSD suitable for device closure.
Patients with right coronary cusp prolapse, pulmonary hypertension, or multiple congenital defects requiring surgery were excluded.
Echocardiography, angiography, and electrocardiography were performed at baseline, post-procedure, and at 1, 3, 6, and 12 months.
The study received ethical approval and adhered to the Declaration of Helsinki.
Descriptive analysis was conducted using SPSS v26.
Results: The mean age was 9.
6 ± 5 years and weight 23.
6 ± 12.
4 kg.
Immediate closure was achieved in 97.
6%, sustained in 95.
2% at 12 months.
No cases of AV block, haemolysis, or significant arrhythmias were observed.
Mild, non-progressive aortic regurgitation occurred in one patient (2.
4%); tricuspid regurgitation improved over time.
One unrelated death occurred at 12 months.
Valvular function and ECG remained stable with no statistically significant deterioration (p > 0.
05).
Conclusion: Transcatheter PM VSD closure using the KONAR-MF occluder is a safe and effective alternative to surgery in selected pediatric patients, offering high closure rates and a low complication profile, supporting its clinical applicability in structural heart disease management.
Related Results
COMPARATIVE STUDY OF TWO OCCLUDER-RELEASE TECHNIQUES IN TRANSCATHETER CLOSURE OF PERIMEMBRANOUS VENTRICULAR SEPTAL DEFECT
COMPARATIVE STUDY OF TWO OCCLUDER-RELEASE TECHNIQUES IN TRANSCATHETER CLOSURE OF PERIMEMBRANOUS VENTRICULAR SEPTAL DEFECT
Objectives
Reported experience with the retained guidewire technique in transcatheter closure of perimembranous ventricular septal defect (VSD) is limited. To com...
The clinical evaluation of transcatheter closure of perimembranous ventricular septal defects with the Amplatzer duct occluder II
The clinical evaluation of transcatheter closure of perimembranous ventricular septal defects with the Amplatzer duct occluder II
Objectives
Investigate the feasibility of perimembranous ventricular septal defects closure with the Amplatzer duct occluder II.
...
Cardiovascular Malformations Among Preterm Infants
Cardiovascular Malformations Among Preterm Infants
Objective. Preterm birth and cardiovascular malformations are the 2 most common causes of neonatal and infant death, but there are no published population-based reports on the rela...
Transcatheter and hybrid closure of muscular ventricular septal defects using the KONAR-MF™ occluder: a multicentre paediatric experience in India
Transcatheter and hybrid closure of muscular ventricular septal defects using the KONAR-MF™ occluder: a multicentre paediatric experience in India
Abstract
Background:
The KONAR-MF™ occluder, with its flexible medium-profile design, has broadened the feasibility of tr...
Ventricular septal defect in children and adults by echocardiography study in Iraqi patients
Ventricular septal defect in children and adults by echocardiography study in Iraqi patients
Objective: A ventricular septal defect (VSD) is defined as a communication between the left and right ventricles or between the left ventricle and the right atrium. VSDs are amongs...
Multifunctional Device (Konar-MF-VSD) for Percutaneous Closure of Ventricular Septal Defects Cases Report
Multifunctional Device (Konar-MF-VSD) for Percutaneous Closure of Ventricular Septal Defects Cases Report
A ventricular septal defect (VSD) is communication between both ventricles. There are diferent types of VSDs based on anatomy. At the National Institute of Child Health San Borja (...
Muscular ventricular septal defect closure with Gianturco coil at Soetomo hospital (a case report)
Muscular ventricular septal defect closure with Gianturco coil at Soetomo hospital (a case report)
Ventricular septal defect (VSD) is the mostcommon congenital heart disease (CHD)in children.1'2 It occurs in 1.5 to 3.5 of1,000 live births and constitutes 20% ofcongenital cardiac...
Advanced three-dimensional surgical planning of complex ventricular anatomy in transposition of the great arteries
Advanced three-dimensional surgical planning of complex ventricular anatomy in transposition of the great arteries
Abstract
This is a case of a 6-week-old male with D-TGA and multiple large ventricular septal defects who presented with oxygen desaturations into the 60s. He had initially unde...

