Comparison of four formulas for the intraocular lens power prediction
View through CrossRef
Abstract
Purpose
To assess the accuracy of four formulas for intraocular lens (IOL) power prediction in cataractous eyes.
METHODS
In this prospective study, 51 eyes of 38 cataractous patients with an axial length (AL) between 24.0 and 26.0 mm were included. Preoperatively, Topolyzer, IOLMaster and A-scan were performed. At least 3 months after the surgery, subjective refraction was conducted. Haigis, SRK/T, Hoffer Q and Holladay 1 formulas based on ocular biometry from A-scan combining Topolyzer, IOLMaster combining Topolyzer and IOLMaster only were applied for IOL power prediction.
RESULTS
The four formulas based on biometry from IOLMaster combining Topolyzer and IOLMaster only performed better than those based on biometry from A-scan combining Topolyzer. Based on biometry from IOLMaster combining Topolyzer, Haigis formula had a mean NEs of -0.03 ± 0.71 D and a mean AEs of 0.53 ± 0.47 D, SRK/T formula had a mean NEs of 0.37 ± 0.72 D and a mean AEs of 0.63 ± 0.50 D, Hoffer Q formula had a mean NEs of 0.05 ± 0.62 D and a mean AEs of 0.43 ± 0.44 D, Holladay 1 formula had a mean NEs of 0.32 ± 0.63 D and a mean AEs of 0.54 ± 0.45 D. Based on biometry from IOLMaster only, Haigis formula had a mean NEs of 0.02 ± 0.54 D and a mean AEs of 0.41 ± 0.36 D, SRK/T formula had a mean NEs of 0.41 ± 0.54 D and a mean AEs of 0.52 ± 0.43 D, Hoffer Q formula had a mean NEs of 0.05 ± 0.58 D and a mean AEs of 0.36 ± 0.46 D, Holladay 1 formula had a mean NEs of 0.32 ± 0.45 D and a mean AEs of 0.43 ± 0.35 D.
CONCLUSIONS
Haigis and Hoffer Q formulas performed slightly better than SRK/T and Holladay 1 formulas. Therefore, for cataractous patients with moderate AL, all four formulas based the biometry from IOLMaster combining Topolyzer and IOLMaster only can be used for the prediction of IOL power, and the Haigis and Hoffer Q formulas are particularly recommended.
Title: Comparison of four formulas for the intraocular lens power prediction
Description:
Abstract
Purpose
To assess the accuracy of four formulas for intraocular lens (IOL) power prediction in cataractous eyes.
METHODS
In this prospective study, 51 eyes of 38 cataractous patients with an axial length (AL) between 24.
0 and 26.
0 mm were included.
Preoperatively, Topolyzer, IOLMaster and A-scan were performed.
At least 3 months after the surgery, subjective refraction was conducted.
Haigis, SRK/T, Hoffer Q and Holladay 1 formulas based on ocular biometry from A-scan combining Topolyzer, IOLMaster combining Topolyzer and IOLMaster only were applied for IOL power prediction.
RESULTS
The four formulas based on biometry from IOLMaster combining Topolyzer and IOLMaster only performed better than those based on biometry from A-scan combining Topolyzer.
Based on biometry from IOLMaster combining Topolyzer, Haigis formula had a mean NEs of -0.
03 ± 0.
71 D and a mean AEs of 0.
53 ± 0.
47 D, SRK/T formula had a mean NEs of 0.
37 ± 0.
72 D and a mean AEs of 0.
63 ± 0.
50 D, Hoffer Q formula had a mean NEs of 0.
05 ± 0.
62 D and a mean AEs of 0.
43 ± 0.
44 D, Holladay 1 formula had a mean NEs of 0.
32 ± 0.
63 D and a mean AEs of 0.
54 ± 0.
45 D.
Based on biometry from IOLMaster only, Haigis formula had a mean NEs of 0.
02 ± 0.
54 D and a mean AEs of 0.
41 ± 0.
36 D, SRK/T formula had a mean NEs of 0.
41 ± 0.
54 D and a mean AEs of 0.
52 ± 0.
43 D, Hoffer Q formula had a mean NEs of 0.
05 ± 0.
58 D and a mean AEs of 0.
36 ± 0.
46 D, Holladay 1 formula had a mean NEs of 0.
32 ± 0.
45 D and a mean AEs of 0.
43 ± 0.
35 D.
CONCLUSIONS
Haigis and Hoffer Q formulas performed slightly better than SRK/T and Holladay 1 formulas.
Therefore, for cataractous patients with moderate AL, all four formulas based the biometry from IOLMaster combining Topolyzer and IOLMaster only can be used for the prediction of IOL power, and the Haigis and Hoffer Q formulas are particularly recommended.
Related Results
The effect of different milk formulas on dental plaque pH
The effect of different milk formulas on dental plaque pH
Summary. Objectives. The purposes of this study were (1) to investigate the effect of different milk formulas on dental plaque pH after rinsing with these three categories, type of...
Morphometric OCT parameters of the lens under accommodative stimulus. Report 1. Assessment of age-related changes
Morphometric OCT parameters of the lens under accommodative stimulus. Report 1. Assessment of age-related changes
Introduction. The structural approach to studying the mechanism of accommodation and its age-related changes focuses on analyzing morphometric parameters (size, shape, and position...
Comparison of the accuracy of 9 intraocular lens power calculation formulas after SMILE in Chinese myopic eyes
Comparison of the accuracy of 9 intraocular lens power calculation formulas after SMILE in Chinese myopic eyes
Abstract
As of 2021, over 2.8 million cases of small incision lenticule extraction (SMILE) procedures had been performed in China. However, there remains limited knowledge ...
Refractive prediction by various intraocular lens formulas using optical biometry and effect of ocular parameters on their accuracy
Refractive prediction by various intraocular lens formulas using optical biometry and effect of ocular parameters on their accuracy
Purpose:
To assess the prediction accuracy of intraocular lens (IOL) formulas and study the effect of axial length (AL), central corneal thickness (CCT), anterior chamb...
Effect of Fasting on Intraocular Pressure
Effect of Fasting on Intraocular Pressure
Purpose: To determine the effect of fasting on intraocular pressure in fasting individuals.
Study Design: Cross sectional observational study.
Place and Duration of S...
Impact and Correction of an Anterior Phakic Intraocular Lens on Swept-Source Optical Coherence Tomography Biometry
Impact and Correction of an Anterior Phakic Intraocular Lens on Swept-Source Optical Coherence Tomography Biometry
Purpose:
To evaluate the impact of anterior chamber phakic intraocular lens (pIOL) on swept-source optical coherence tomography (SS-OCT) biometric measurements and IOL ...
Urrets-Zavalia syndrome following implantable collamer lens (ICL) implantation: a case report and review of the literature
Urrets-Zavalia syndrome following implantable collamer lens (ICL) implantation: a case report and review of the literature
Abstract
Background
Urrets-Zavalia syndrome is a condition that arises after eye surgery, often linked to increased intraocular pressure followin...
The Effects of Different Shapes of Capsulorrhexis on Postoperative Refractive Outcomes and Effective Position of the Intraocular Lens in Cataract Surgery
The Effects of Different Shapes of Capsulorrhexis on Postoperative Refractive Outcomes and Effective Position of the Intraocular Lens in Cataract Surgery
Abstract
Background:To evaluate the effects of anterior capsular opening size on deviation from predicted refraction and the effective position of the intraocular lens (ELP...