Optimal operation of paralleled power transformers
View through CrossRef
Parallel operation of power transformers is a common practice. Interest is placed on minimizing the reactive current circulation between transformers due to mismatching of electrical properties. Several control schemes have been applied over the years to ensure efficient operation of paralleled transformers with OLTC. These methods rely either on field measurements of circulating currents or on classic Master/Follower approach and usually assume that the paralleled transformers have matching impedances and OLTC positions. On the present work a generalized approach is implemented calculating the circulating current and minimizing losses directly at the System Operation Office and using the distribution system SCADA to control tap position of the paralleled transformers. This permits the determination of optimal tap matching between transformers and calculation of losses under emergency situations where coupling of transformers with slight impedance mismatch might be considered. In the proposed method a map of circulating current is calculated based on the transformer impedance, X/R ratio and OLTC positions, then the optimal tap positions (minimizing losses) under parallel operation are determined.
Title: Optimal operation of paralleled power transformers
Description:
Parallel operation of power transformers is a common practice.
Interest is placed on minimizing the reactive current circulation between transformers due to mismatching of electrical properties.
Several control schemes have been applied over the years to ensure efficient operation of paralleled transformers with OLTC.
These methods rely either on field measurements of circulating currents or on classic Master/Follower approach and usually assume that the paralleled transformers have matching impedances and OLTC positions.
On the present work a generalized approach is implemented calculating the circulating current and minimizing losses directly at the System Operation Office and using the distribution system SCADA to control tap position of the paralleled transformers.
This permits the determination of optimal tap matching between transformers and calculation of losses under emergency situations where coupling of transformers with slight impedance mismatch might be considered.
In the proposed method a map of circulating current is calculated based on the transformer impedance, X/R ratio and OLTC positions, then the optimal tap positions (minimizing losses) under parallel operation are determined.
Related Results
CREATION OF A STRUCTURAL MODEL OF AN POWER TRANSFORMERS IN THE FORM OF AC TRANSFORMING COMPLEXES
CREATION OF A STRUCTURAL MODEL OF AN POWER TRANSFORMERS IN THE FORM OF AC TRANSFORMING COMPLEXES
Due to the multiple transformation of electrical energy, the rated capacity of power transformers can be 8 or more times the rated generation capacity. Therefore, the state of reli...
Increasing of Power Oil-Filled Transformers’ Operation Reliability and Safety
Increasing of Power Oil-Filled Transformers’ Operation Reliability and Safety
This paper is devoted to the currently urgent problem — increasing reliability and safety for power oil transformers’ operation with considerable long and short overloads through c...
On the Remote Calibration of Instrumentation Transformers: Influence of Temperature
On the Remote Calibration of Instrumentation Transformers: Influence of Temperature
The remote calibration of instrumentation transformers is theoretically possible using synchronous measurements across a transmission line with a known impedance and a local set of...
Increased Transformer Availability and Reliability
Increased Transformer Availability and Reliability
Abstract
Transformers are important components of the High Voltage electrical grid and electrical power installation in industrial plants such as the petroleum indus...
The influence of harmonics from non-linear loads in the measuring transformers of electrical substations.
The influence of harmonics from non-linear loads in the measuring transformers of electrical substations.
The mainstreams of research papers developed to analysis of electrical systems power quality for non-linear loads are conducted for low voltage feed. This, i...
[RETRACTED] Optimal Max Keto - Does It ReallyWork? v1
[RETRACTED] Optimal Max Keto - Does It ReallyWork? v1
[RETRACTED]Shedding the unwanted weight and controlling the calories of your body is the most challenging and complicated process. As we start aging, we have to deal with lots of...
Transformers Health Index Assessment Based on Neural-Fuzzy Network
Transformers Health Index Assessment Based on Neural-Fuzzy Network
In this paper, an assessment on the health index (HI) of transformers is carried out based on Neural-Fuzzy (NF) method. In-service condition assessment data, such as dissolved gase...
Application of Time/Temperature Fire Curves for the Estimation of Fire Resistance of Transformer within Protective Structures
Application of Time/Temperature Fire Curves for the Estimation of Fire Resistance of Transformer within Protective Structures
At each power facility, a number of key elements can be identified thanks to which the power industry functions. One of these elements is transformers, which contain oil in their c...