Increasing of Power Oil-Filled Transformers’ Operation Reliability and Safety

View through CrossRef
This paper is devoted to the currently urgent problem — increasing reliability and safety for power oil transformers’ operation with considerable long and short overloads through cooling systems’ efficiency upgrading, allowing increase the power oil transformers’ operation safety, engine life, reliability and economical efficiency. Statistical data on fault causes for transformers of different voltage classes and lifecycles have been given. Based on the study of statistical data it has been established that one of the main causes for transformers faults was the inefficiency of oil cooling systems during the summer period of operation and with considerable long and short overloads. For improvement of efficiency of power oil transformers’ cooling system the agitation of cooling oil by circulating sulfur hexafluoride (SF6) and subsequent sulfur hexafluoride cooling with a thermoelectric cooler is proposed. The system of sulfur hexafluoride circulation and cooling switches on automatically at considerable long and short overloads. The design and operation of the proposed cooling system for oil transformers have been considered. A series of laboratory experiments for transformer oil cooling in a power transformer’s tank without and with a compressor has been carried out. Graphs of temperature-time relationship at natural cooling and when using agitation have been presented. The coefficients of transformer oil’s thermal diffusivity and heat transfer at various distances from heating element have been experimentally defined. The mathematical problem of a heat flux distribution in a rectangular parallelepiped has been considered, a solution for thermal conductivity equation in the power transformer’s tank, which is a rectangular parallelepiped, has been presented. A laboratory setup design has been described in detail. Brands of used thermocouples, compressor and analog-digital converter have been presented. Use of the upgraded cooling system will allow increase the transformers operation safety and reliability.
Title: Increasing of Power Oil-Filled Transformers’ Operation Reliability and Safety
Description:
This paper is devoted to the currently urgent problem — increasing reliability and safety for power oil transformers’ operation with considerable long and short overloads through cooling systems’ efficiency upgrading, allowing increase the power oil transformers’ operation safety, engine life, reliability and economical efficiency.
Statistical data on fault causes for transformers of different voltage classes and lifecycles have been given.
Based on the study of statistical data it has been established that one of the main causes for transformers faults was the inefficiency of oil cooling systems during the summer period of operation and with considerable long and short overloads.
For improvement of efficiency of power oil transformers’ cooling system the agitation of cooling oil by circulating sulfur hexafluoride (SF6) and subsequent sulfur hexafluoride cooling with a thermoelectric cooler is proposed.
The system of sulfur hexafluoride circulation and cooling switches on automatically at considerable long and short overloads.
The design and operation of the proposed cooling system for oil transformers have been considered.
A series of laboratory experiments for transformer oil cooling in a power transformer’s tank without and with a compressor has been carried out.
Graphs of temperature-time relationship at natural cooling and when using agitation have been presented.
The coefficients of transformer oil’s thermal diffusivity and heat transfer at various distances from heating element have been experimentally defined.
The mathematical problem of a heat flux distribution in a rectangular parallelepiped has been considered, a solution for thermal conductivity equation in the power transformer’s tank, which is a rectangular parallelepiped, has been presented.
A laboratory setup design has been described in detail.
Brands of used thermocouples, compressor and analog-digital converter have been presented.
Use of the upgraded cooling system will allow increase the transformers operation safety and reliability.

Related Results

CREATION OF A STRUCTURAL MODEL OF AN POWER TRANSFORMERS IN THE FORM OF AC TRANSFORMING COMPLEXES
CREATION OF A STRUCTURAL MODEL OF AN POWER TRANSFORMERS IN THE FORM OF AC TRANSFORMING COMPLEXES
Due to the multiple transformation of electrical energy, the rated capacity of power transformers can be 8 or more times the rated generation capacity. Therefore, the state of reli...
Domination of Polynomial with Application
Domination of Polynomial with Application
In this paper, .We .initiate the study of domination. polynomial , consider G=(V,E) be a simple, finite, and directed graph without. isolated. vertex .We present a study of the Ira...
On the Remote Calibration of Instrumentation Transformers: Influence of Temperature
On the Remote Calibration of Instrumentation Transformers: Influence of Temperature
The remote calibration of instrumentation transformers is theoretically possible using synchronous measurements across a transmission line with a known impedance and a local set of...
Evaluating Effects of Culture and Language on Safety
Evaluating Effects of Culture and Language on Safety
This paper (SPE 54448) was revised for publication from paper SPE 48891, prepared for the 1998 SPE International Conference and Exhibition held in Beijing, 2–6 November. Original m...
Increased Transformer Availability and Reliability
Increased Transformer Availability and Reliability
Abstract Transformers are important components of the High Voltage electrical grid and electrical power installation in industrial plants such as the petroleum indus...
Optimal operation of paralleled power transformers
Optimal operation of paralleled power transformers
Parallel operation of power transformers is a common practice. Interest is placed on minimizing the reactive current circulation between transformers due to mismatching of electric...
Factors Influencing Patient Safety Management Behaviors in Nursing Students
Factors Influencing Patient Safety Management Behaviors in Nursing Students
The objective of this study is to identify the critical thinking Disposition, problem-solving processes, safety motivation, patient safety management knowledge, attitudes towards p...
Application of Time/Temperature Fire Curves for the Estimation of Fire Resistance of Transformer within Protective Structures
Application of Time/Temperature Fire Curves for the Estimation of Fire Resistance of Transformer within Protective Structures
At each power facility, a number of key elements can be identified thanks to which the power industry functions. One of these elements is transformers, which contain oil in their c...