Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Dark count of 20-inch PMTs generated by natural radioactivity

View through CrossRef
Abstract The primary objective of the JUNO experiment is to determine the ordering of neutrino masses using a 20-kton liquid-scintillator detector. The 20-inch photomultiplier tube (PMT) plays a crucial role in achieving excellent energy resolution of at least 3 % at 1 MeV. Understanding the characteristics and features of the PMT is vital for comprehending the detector's performance, particularly regarding the occurrence of large pulses in PMT dark counts. This research paper aims to further investigate the origin of these large pulses in the 20-inch PMT dark count through measurements and simulations. Our results confirm that natural radioactivity and muons striking the PMT glass are the main sources of the large pulses. We evaluate their contribution quantitatively by performing spectrum fitting. By analyzing the PMT dark count spectrum, it becomes possible to roughly estimate the radioactivity levels in the surrounding environment.
Title: Dark count of 20-inch PMTs generated by natural radioactivity
Description:
Abstract The primary objective of the JUNO experiment is to determine the ordering of neutrino masses using a 20-kton liquid-scintillator detector.
The 20-inch photomultiplier tube (PMT) plays a crucial role in achieving excellent energy resolution of at least 3 % at 1 MeV.
Understanding the characteristics and features of the PMT is vital for comprehending the detector's performance, particularly regarding the occurrence of large pulses in PMT dark counts.
This research paper aims to further investigate the origin of these large pulses in the 20-inch PMT dark count through measurements and simulations.
Our results confirm that natural radioactivity and muons striking the PMT glass are the main sources of the large pulses.
We evaluate their contribution quantitatively by performing spectrum fitting.
By analyzing the PMT dark count spectrum, it becomes possible to roughly estimate the radioactivity levels in the surrounding environment.

Related Results

Dark count rate stability of JUNO 20-inch PMTs in mass testing
Dark count rate stability of JUNO 20-inch PMTs in mass testing
Abstract The Jiangmen Underground Neutrino Observatory (JUNO) is an ambitious multipurpose neutrino experiment designed to determine the neutrino mass ordering, ...
Mass testing and characterization of 20-inch PMTs for JUNO
Mass testing and characterization of 20-inch PMTs for JUNO
Abstract Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20 kt liquid-scintillator detector. Its key feature is an excellent energy re...
The Detectors based on PMTs
The Detectors based on PMTs
Abstract As a vacuum photoelectric device, the photomultiplier tube (PMT) has a very wide range of applications in the field of weak optical signal detection. Compar...
Analysis of tail phenomena in micro-channel plate PMTs
Analysis of tail phenomena in micro-channel plate PMTs
Abstract Photomultiplier Tubes (PMTs) employing micro-channel plate (MCP) are a type of light-detection device designed for weak-light conditions. The MCP multip...
20-inch photomultiplier tube timing study for JUNO
20-inch photomultiplier tube timing study for JUNO
Abstract Jiangmen Underground Neutrino Observatory (JUNO) is a large liquid scintillator neutrino detector now under construction at Jiangmen, Guangdong, China for d...
Tracing Hematological Shifts in Pregnancy: How Anemia and Thrombocytopenia Evolve Across Trimesters
Tracing Hematological Shifts in Pregnancy: How Anemia and Thrombocytopenia Evolve Across Trimesters
Abstract Introduction Given pregnancy's significant impact on hematological parameters, monitoring these changes across trimesters is crucial. This study aims to evaluate hematolog...
Power Transformer Wire Estimate
Power Transformer Wire Estimate
This experimental study determined the weight of wire used in power supply using the laboratory technique and procedure to gather data. There were two designs with three treatments...

Back to Top