Dark count rate stability of JUNO 20-inch PMTs in mass testing
View through CrossRef
Abstract
The Jiangmen Underground Neutrino Observatory (JUNO) is an
ambitious multipurpose neutrino experiment designed to determine the
neutrino mass ordering, with an impressive energy resolution goal of
at least 3% at 1 MeV. To achieve a photon detection coverage of
approximately 75%, JUNO will utilize two types of 20-inch
photomultiplier tubes (PMTs): the large PMT (LPMT) and the
microchannel plate PMT (MCP-PMT). A significant concern in
high-precision neutrino measurements is the dark count rate (DCR) of
PMTs, which introduces noise that can adversely affect energy
measurement accuracy. During the mass testing phase of the JUNO
20-inch PMTs, comprehensive measurements of the DCR were
undertaken. These measurements not only captured the DCR values of
individual PMTs but also examined the stability and temperature
dependence of the DCR at an operating gain of (1 × 107).
This paper presents a detailed characterization of the DCR of the
JUNO 20-inch PMTs, investigating factors such as cooling time,
temperature variations, and long-term stability using the JUNO
Pan-Asia PMT testing facilities. The results reveal distinct DCR
characteristics between the two types of PMTs, providing valuable
insights into the nature of DCR and its implications for JUNO's
scientific objectives. In addition to performance characterization,
we implemented a monitoring system to track DCR stability over
time. Notably, several spikes in DCR were identified, prompting a
preliminary investigation into their causes. Potential factors
contributing to these spikes, such as flasher events, were explored
using coincidence rate analysis and complementary imaging
techniques. The findings from this study are crucial for optimizing
the performance of PMTs in JUNO, ultimately aiding the experiment in
achieving its goals related to neutrino physics.
IOP Publishing
Title: Dark count rate stability of JUNO 20-inch PMTs in mass testing
Description:
Abstract
The Jiangmen Underground Neutrino Observatory (JUNO) is an
ambitious multipurpose neutrino experiment designed to determine the
neutrino mass ordering, with an impressive energy resolution goal of
at least 3% at 1 MeV.
To achieve a photon detection coverage of
approximately 75%, JUNO will utilize two types of 20-inch
photomultiplier tubes (PMTs): the large PMT (LPMT) and the
microchannel plate PMT (MCP-PMT).
A significant concern in
high-precision neutrino measurements is the dark count rate (DCR) of
PMTs, which introduces noise that can adversely affect energy
measurement accuracy.
During the mass testing phase of the JUNO
20-inch PMTs, comprehensive measurements of the DCR were
undertaken.
These measurements not only captured the DCR values of
individual PMTs but also examined the stability and temperature
dependence of the DCR at an operating gain of (1 × 107).
This paper presents a detailed characterization of the DCR of the
JUNO 20-inch PMTs, investigating factors such as cooling time,
temperature variations, and long-term stability using the JUNO
Pan-Asia PMT testing facilities.
The results reveal distinct DCR
characteristics between the two types of PMTs, providing valuable
insights into the nature of DCR and its implications for JUNO's
scientific objectives.
In addition to performance characterization,
we implemented a monitoring system to track DCR stability over
time.
Notably, several spikes in DCR were identified, prompting a
preliminary investigation into their causes.
Potential factors
contributing to these spikes, such as flasher events, were explored
using coincidence rate analysis and complementary imaging
techniques.
The findings from this study are crucial for optimizing
the performance of PMTs in JUNO, ultimately aiding the experiment in
achieving its goals related to neutrino physics.
Related Results
Mass testing and characterization of 20-inch PMTs for JUNO
Mass testing and characterization of 20-inch PMTs for JUNO
Abstract
Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20 kt liquid-scintillator detector. Its key feature is an excellent energy re...
FILM KUCUMBU TUBUH INDAHKU DALAM PERSPEKTIF FENOMENOLOGI TUBUH MERLEAU-PONTY
FILM KUCUMBU TUBUH INDAHKU DALAM PERSPEKTIF FENOMENOLOGI TUBUH MERLEAU-PONTY
Abstrak: Penelitian ini berangkat dari permasalahan relasi tubuh dan jiwa yang telah diperdebatkan selama berabad-abad oleh para pemikir Barat. Salah satu film yang cukup menyita p...
Utility of Multimodality Approach Including Systemic FGF23 Venous Sampling in Localizing Phosphaturic Mesenchymal Tumors
Utility of Multimodality Approach Including Systemic FGF23 Venous Sampling in Localizing Phosphaturic Mesenchymal Tumors
Abstract
Context
Tumor-induced osteomalacia (TIO) is one of the most common forms of acquired fibroblast growth factor 23 (FGF23...
The Detectors based on PMTs
The Detectors based on PMTs
Abstract
As a vacuum photoelectric device, the photomultiplier tube (PMT) has a very wide range of applications in the field of weak optical signal detection. Compar...
Analysis of tail phenomena in micro-channel plate PMTs
Analysis of tail phenomena in micro-channel plate PMTs
Abstract
Photomultiplier Tubes (PMTs) employing micro-channel plate
(MCP) are a type of light-detection device designed for weak-light
conditions. The MCP multip...
20-inch photomultiplier tube timing study for JUNO
20-inch photomultiplier tube timing study for JUNO
Abstract
Jiangmen Underground Neutrino Observatory (JUNO) is a large liquid scintillator neutrino detector now under construction at Jiangmen, Guangdong, China for d...
Characterization of the JUNO Large-PMT readout electronics
Characterization of the JUNO Large-PMT readout electronics
Abstract
The Jiangmen Underground Neutrino Observatory (JUNO) is a neutrino medium baseline experiment under construction in Southern China, expecting to begin data ...
Tracing Hematological Shifts in Pregnancy: How Anemia and Thrombocytopenia Evolve Across Trimesters
Tracing Hematological Shifts in Pregnancy: How Anemia and Thrombocytopenia Evolve Across Trimesters
Abstract
Introduction
Given pregnancy's significant impact on hematological parameters, monitoring these changes across trimesters is crucial. This study aims to evaluate hematolog...