Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Dark count rate stability of JUNO 20-inch PMTs in mass testing

View through CrossRef
Abstract The Jiangmen Underground Neutrino Observatory (JUNO) is an ambitious multipurpose neutrino experiment designed to determine the neutrino mass ordering, with an impressive energy resolution goal of at least 3% at 1 MeV. To achieve a photon detection coverage of approximately 75%, JUNO will utilize two types of 20-inch photomultiplier tubes (PMTs): the large PMT (LPMT) and the microchannel plate PMT (MCP-PMT). A significant concern in high-precision neutrino measurements is the dark count rate (DCR) of PMTs, which introduces noise that can adversely affect energy measurement accuracy. During the mass testing phase of the JUNO 20-inch PMTs, comprehensive measurements of the DCR were undertaken. These measurements not only captured the DCR values of individual PMTs but also examined the stability and temperature dependence of the DCR at an operating gain of (1 × 107). This paper presents a detailed characterization of the DCR of the JUNO 20-inch PMTs, investigating factors such as cooling time, temperature variations, and long-term stability using the JUNO Pan-Asia PMT testing facilities. The results reveal distinct DCR characteristics between the two types of PMTs, providing valuable insights into the nature of DCR and its implications for JUNO's scientific objectives. In addition to performance characterization, we implemented a monitoring system to track DCR stability over time. Notably, several spikes in DCR were identified, prompting a preliminary investigation into their causes. Potential factors contributing to these spikes, such as flasher events, were explored using coincidence rate analysis and complementary imaging techniques. The findings from this study are crucial for optimizing the performance of PMTs in JUNO, ultimately aiding the experiment in achieving its goals related to neutrino physics.
Title: Dark count rate stability of JUNO 20-inch PMTs in mass testing
Description:
Abstract The Jiangmen Underground Neutrino Observatory (JUNO) is an ambitious multipurpose neutrino experiment designed to determine the neutrino mass ordering, with an impressive energy resolution goal of at least 3% at 1 MeV.
To achieve a photon detection coverage of approximately 75%, JUNO will utilize two types of 20-inch photomultiplier tubes (PMTs): the large PMT (LPMT) and the microchannel plate PMT (MCP-PMT).
A significant concern in high-precision neutrino measurements is the dark count rate (DCR) of PMTs, which introduces noise that can adversely affect energy measurement accuracy.
During the mass testing phase of the JUNO 20-inch PMTs, comprehensive measurements of the DCR were undertaken.
These measurements not only captured the DCR values of individual PMTs but also examined the stability and temperature dependence of the DCR at an operating gain of (1 × 107).
This paper presents a detailed characterization of the DCR of the JUNO 20-inch PMTs, investigating factors such as cooling time, temperature variations, and long-term stability using the JUNO Pan-Asia PMT testing facilities.
The results reveal distinct DCR characteristics between the two types of PMTs, providing valuable insights into the nature of DCR and its implications for JUNO's scientific objectives.
In addition to performance characterization, we implemented a monitoring system to track DCR stability over time.
Notably, several spikes in DCR were identified, prompting a preliminary investigation into their causes.
Potential factors contributing to these spikes, such as flasher events, were explored using coincidence rate analysis and complementary imaging techniques.
The findings from this study are crucial for optimizing the performance of PMTs in JUNO, ultimately aiding the experiment in achieving its goals related to neutrino physics.

Related Results

Mass testing and characterization of 20-inch PMTs for JUNO
Mass testing and characterization of 20-inch PMTs for JUNO
Abstract Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20 kt liquid-scintillator detector. Its key feature is an excellent energy re...
FILM KUCUMBU TUBUH INDAHKU DALAM PERSPEKTIF FENOMENOLOGI TUBUH MERLEAU-PONTY
FILM KUCUMBU TUBUH INDAHKU DALAM PERSPEKTIF FENOMENOLOGI TUBUH MERLEAU-PONTY
Abstrak: Penelitian ini berangkat dari permasalahan relasi tubuh dan jiwa yang telah diperdebatkan selama berabad-abad oleh para pemikir Barat. Salah satu film yang cukup menyita p...
The Detectors based on PMTs
The Detectors based on PMTs
Abstract As a vacuum photoelectric device, the photomultiplier tube (PMT) has a very wide range of applications in the field of weak optical signal detection. Compar...
Analysis of tail phenomena in micro-channel plate PMTs
Analysis of tail phenomena in micro-channel plate PMTs
Abstract Photomultiplier Tubes (PMTs) employing micro-channel plate (MCP) are a type of light-detection device designed for weak-light conditions. The MCP multip...
20-inch photomultiplier tube timing study for JUNO
20-inch photomultiplier tube timing study for JUNO
Abstract Jiangmen Underground Neutrino Observatory (JUNO) is a large liquid scintillator neutrino detector now under construction at Jiangmen, Guangdong, China for d...
Characterization of the JUNO Large-PMT readout electronics
Characterization of the JUNO Large-PMT readout electronics
Abstract The Jiangmen Underground Neutrino Observatory (JUNO) is a neutrino medium baseline experiment under construction in Southern China, expecting to begin data ...
Tracing Hematological Shifts in Pregnancy: How Anemia and Thrombocytopenia Evolve Across Trimesters
Tracing Hematological Shifts in Pregnancy: How Anemia and Thrombocytopenia Evolve Across Trimesters
Abstract Introduction Given pregnancy's significant impact on hematological parameters, monitoring these changes across trimesters is crucial. This study aims to evaluate hematolog...

Back to Top