Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

PreserFlo® MicroShunt: An Overview of This Minimally Invasive Device for Open-Angle Glaucoma

View through CrossRef
For moderate-to-severe glaucoma, trabeculectomy remains the “gold standard” intraocular pressure (IOP)-lowering treatment; nonetheless, this method requires extensive post-operative maintenance. Microinvasive glaucoma surgery (MIGS) treatments are designed to lessen intra- and post-operative care burden while offering an acceptable IOP decrease for individuals with mild to moderate glaucoma. The PreserFlo® MicroShunt (previously InnFocus MicroShunt) is an 8.5 mm glaucoma drainage device manufactured from poly(styrene-block-isobutylene-block-styrene) (SIBS), an extremely biocompatible and bioinert material. The lumen is narrow enough to prevent hypotony, but big enough to avoid being obstructed by sloughed cells or pigment. The device is implanted ab externo, as a stand-alone procedure or in conjunction with cataract surgery, with intraoperative mitomycin C, and a bleb is produced under the conjunctiva and Tenon’s capsule. The MicroShunt was CE-marked in 2012 and designed for primary open-angle glaucoma, the IOP of which remains uncontrolled after maximally tolerated topical treatment. Several clinical trials evaluating the MicroShunt’s long-term safety and effectiveness have been conducted, highlighting the effectiveness of the device over time, along with a tolerable safety profile. The present review aims to gather evidence of PreserFlo’s effectiveness and safety results almost 10 years after its introduction, and furthermore, to compare it with other MIGS and with the gold-standard trabeculectomy for glaucoma management.
Title: PreserFlo® MicroShunt: An Overview of This Minimally Invasive Device for Open-Angle Glaucoma
Description:
For moderate-to-severe glaucoma, trabeculectomy remains the “gold standard” intraocular pressure (IOP)-lowering treatment; nonetheless, this method requires extensive post-operative maintenance.
Microinvasive glaucoma surgery (MIGS) treatments are designed to lessen intra- and post-operative care burden while offering an acceptable IOP decrease for individuals with mild to moderate glaucoma.
The PreserFlo® MicroShunt (previously InnFocus MicroShunt) is an 8.
5 mm glaucoma drainage device manufactured from poly(styrene-block-isobutylene-block-styrene) (SIBS), an extremely biocompatible and bioinert material.
The lumen is narrow enough to prevent hypotony, but big enough to avoid being obstructed by sloughed cells or pigment.
The device is implanted ab externo, as a stand-alone procedure or in conjunction with cataract surgery, with intraoperative mitomycin C, and a bleb is produced under the conjunctiva and Tenon’s capsule.
The MicroShunt was CE-marked in 2012 and designed for primary open-angle glaucoma, the IOP of which remains uncontrolled after maximally tolerated topical treatment.
Several clinical trials evaluating the MicroShunt’s long-term safety and effectiveness have been conducted, highlighting the effectiveness of the device over time, along with a tolerable safety profile.
The present review aims to gather evidence of PreserFlo’s effectiveness and safety results almost 10 years after its introduction, and furthermore, to compare it with other MIGS and with the gold-standard trabeculectomy for glaucoma management.

Related Results

Staphylococcus Capitus Blebitis Following Preserflo MicroShunt Implantation
Staphylococcus Capitus Blebitis Following Preserflo MicroShunt Implantation
Purpose: To report a case of early-onset blebitis following Preserflo MicroShunt implantation. Patients and Methods: Case ...
PRESERFLO MicroShunt
PRESERFLO MicroShunt
Abstract The PRESERFLO® MicroShunt (Santen Pharmaceutical Co. Ltd., Osaka, Japan), formerly called the InnFocus MicroShunt®, is a trans-scleral device that shunts aqueous humour fr...
Childhood glaucoma profile in a Southwestern Ethiopia tertiary care center: a retrospective study
Childhood glaucoma profile in a Southwestern Ethiopia tertiary care center: a retrospective study
Abstract Background Childhood glaucoma is a major cause of childhood blindness worldwide. The profile of childhood glaucoma has not been well characterized in sub-Saharan ...
PreserFlo® MicroShunt: Ein Überblick über dieses minimalinvasive Gerät zur Behandlung des Offenwinkelglaukoms
PreserFlo® MicroShunt: Ein Überblick über dieses minimalinvasive Gerät zur Behandlung des Offenwinkelglaukoms
Bei mittelschwerem bis schwerem Glaukom ist die Trabekulektomie nach wie vor der «Goldstandard» für die Senkung des Augen­innendrucks (IOP); allerdings erfordert diese Methode eine...
Genetics of Glaucoma
Genetics of Glaucoma
Abstract Glaucoma is the major cause of blindness worldwide. Primary open‐angle glaucoma (POAG) and angle closure glaucoma (ACG) are the most pr...
Early evaluation of optic nerve head morphology and choroidal thickness after PreserFlo MicroShunt implantation
Early evaluation of optic nerve head morphology and choroidal thickness after PreserFlo MicroShunt implantation
Abstract Purpose The aim of this study is to investigate changes in choroidal and optic nerve morphological parameters following MicroShunt PreserFl...

Back to Top