Evaluation of Fluid Flow Velocity Variations on the Plate Heat Exchanger Performance

View through CrossRef
Heat exchanger expected to high effectiveness of heat transfer. Type of plate heat exchanger was more efficient compare to another heat exchangers in industrial applications with pressure less than 30 bar. The increased velocity of cold fluid flow has an impact to increase the performance of heat exchanger by  heat transfer rate (Q), heat transfer coefficient (U), and the effectiveness of heat exchanger (ε). The increased velocity of cold fluid flow also incresing the heat transfer rate. The study carried out by variation of the cold fluid velocity at 0.03 m/s, 0.037 m/s, 0.045 m/s, 0.051 m/s and 0.059 m/s. Inlet hot fluid temperature (Th,i) at 45°C and cold fluid temperature (Tc,i) at 27°C constant. The results shows Q value from the original 1570.71 Watt to 1916.16 Watt on the hot side and 1751.89 Watt to 2187.01 Watt on the cold side. The U value from the original 1180.46 W/m2.°C becomes 1408,75 W/m2. °C. The ε value increased from 60.33% to 75.69%. The increasing of  cold fluid velocity directly proportional to the the heat transfer rate (Q) and performance of the plate heat exchanger. This Phenomenon due to the faster circulation of the cold fluid, which causes the cold fluid to quickly return to its initial temperature (Th,i), an than increasing the plate heat exchanger's performance.
Title: Evaluation of Fluid Flow Velocity Variations on the Plate Heat Exchanger Performance
Description:
Heat exchanger expected to high effectiveness of heat transfer.
Type of plate heat exchanger was more efficient compare to another heat exchangers in industrial applications with pressure less than 30 bar.
The increased velocity of cold fluid flow has an impact to increase the performance of heat exchanger by  heat transfer rate (Q), heat transfer coefficient (U), and the effectiveness of heat exchanger (ε).
The increased velocity of cold fluid flow also incresing the heat transfer rate.
The study carried out by variation of the cold fluid velocity at 0.
03 m/s, 0.
037 m/s, 0.
045 m/s, 0.
051 m/s and 0.
059 m/s.
Inlet hot fluid temperature (Th,i) at 45°C and cold fluid temperature (Tc,i) at 27°C constant.
The results shows Q value from the original 1570.
71 Watt to 1916.
16 Watt on the hot side and 1751.
89 Watt to 2187.
01 Watt on the cold side.
The U value from the original 1180.
46 W/m2.
°C becomes 1408,75 W/m2.
°C.
The ε value increased from 60.
33% to 75.
69%.
The increasing of  cold fluid velocity directly proportional to the the heat transfer rate (Q) and performance of the plate heat exchanger.
This Phenomenon due to the faster circulation of the cold fluid, which causes the cold fluid to quickly return to its initial temperature (Th,i), an than increasing the plate heat exchanger's performance.

Related Results

Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Abstrak Heat exchanger atau alat penukar panas adalah alat-alat yang digunakan untuk mengubah temperatur fluida atau mengubah fasa fluida dengan cara mempertukarkan panasnya dengan...
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Abstract This paper presents the design and cost optimization of a novel 2MWth 3-stream sCO2 plate-fin heat exchanger. This heat exchanger design is unique in that i...
Heat‐Exchange Technology, Heat Transfer
Heat‐Exchange Technology, Heat Transfer
AbstractIn order to select a proper heat exchanger for a given application, various factors such as pressure, temperature, size, fouling factor, and the use of toxic or corrosive f...
Intelligent Monitoring and Diagnosis of CCWS Heat Exchanger For Nuclear Power Plant
Intelligent Monitoring and Diagnosis of CCWS Heat Exchanger For Nuclear Power Plant
Abstract Component Cooling Water System (CCWS) heat exchanger in nuclear power plant plays an important role in normal operation and accident condition. Because of t...
Design and Analysis of a Plate Heat Exchanger in the View of Performance Improvement and Cost Reduction
Design and Analysis of a Plate Heat Exchanger in the View of Performance Improvement and Cost Reduction
Redesigning of a system is a modification of existing system for reducing the disadvantages over the system and improves the features for getting more output that are desired. For ...
Heat Transfer Enhancement of Ethylene Glycol using Corrugated Plate Heat Exchanger
Heat Transfer Enhancement of Ethylene Glycol using Corrugated Plate Heat Exchanger
This paper presents an experimental study on heat transfer rate for ethylene glycol using a flat plate heat exchanger and various corrugation angles of corrugated plate heat exchan...
Numerical studies on heat transfer characteristics of double pipe and helical coil heat exchangers
Numerical studies on heat transfer characteristics of double pipe and helical coil heat exchangers
Abstract The heat transfer properties of Helical Coil Heat Exchangers and Double Pipe Heat Exchangers are compared in this study utilizing bo...
Experimental Study of Heat Transfer in Concentric Triple Pipe Heat Exchanger
Experimental Study of Heat Transfer in Concentric Triple Pipe Heat Exchanger
Abstract Heat exchangers are devices which are used to transfer the thermal energy between two or more fluids. They are used in various industries for space heating,...