Javascript must be enabled to continue!
Acute Aortic Dissection Biomarkers Identified Using Isobaric Tags for Relative and Absolute Quantitation
View through CrossRef
The purpose of this study was to evaluate the utility of potential serum biomarkers for acute aortic dissection (AAD) that were identified by isobaric Tags for Relative and Absolute Quantitation (iTRAQ) approaches. Serum samples from 20 AAD patients and 20 healthy volunteers were analyzed using iTRAQ technology. Protein validation was performed using samples from 120 patients with chest pain. A total of 355 proteins were identified with the iTRAQ approach; 164 proteins reached the strict quantitative standard, and 125 proteins were increased or decreased more than 1.2-fold (64 and 61 proteins were up- and downregulated, resp.). Lumican, C-reactive protein (CRP), thrombospondin-1 (TSP-1), and D-dimer were selected as candidate biomarkers for the validation tests. Receiver operating characteristic (ROC) curves show that Lumican and D-dimer have diagnostic value (area under the curves [AUCs] 0.895 and 0.891,P<0.05). For Lumican, the diagnostic sensitivity and specificity were 73.33% and 98.33%, while the corresponding values for D-dimer were 93.33% and 68.33%. For Lumican and D-dimer AAD combined diagnosis, the sensitivity and specificity were 88.33% and 95%, respectively. In conclusion, Lumican has good specificity and D-dimer has good sensitivity for the diagnosis of AAD, while the combined detection of D-dimer and Lumican has better diagnostic value.
Title: Acute Aortic Dissection Biomarkers Identified Using Isobaric Tags for Relative and Absolute Quantitation
Description:
The purpose of this study was to evaluate the utility of potential serum biomarkers for acute aortic dissection (AAD) that were identified by isobaric Tags for Relative and Absolute Quantitation (iTRAQ) approaches.
Serum samples from 20 AAD patients and 20 healthy volunteers were analyzed using iTRAQ technology.
Protein validation was performed using samples from 120 patients with chest pain.
A total of 355 proteins were identified with the iTRAQ approach; 164 proteins reached the strict quantitative standard, and 125 proteins were increased or decreased more than 1.
2-fold (64 and 61 proteins were up- and downregulated, resp.
).
Lumican, C-reactive protein (CRP), thrombospondin-1 (TSP-1), and D-dimer were selected as candidate biomarkers for the validation tests.
Receiver operating characteristic (ROC) curves show that Lumican and D-dimer have diagnostic value (area under the curves [AUCs] 0.
895 and 0.
891,P<0.
05).
For Lumican, the diagnostic sensitivity and specificity were 73.
33% and 98.
33%, while the corresponding values for D-dimer were 93.
33% and 68.
33%.
For Lumican and D-dimer AAD combined diagnosis, the sensitivity and specificity were 88.
33% and 95%, respectively.
In conclusion, Lumican has good specificity and D-dimer has good sensitivity for the diagnosis of AAD, while the combined detection of D-dimer and Lumican has better diagnostic value.
Related Results
Accuracy of D-Dimers to diagnose aortic dissection and its different types keeping CT angiogram as gold standard.
Accuracy of D-Dimers to diagnose aortic dissection and its different types keeping CT angiogram as gold standard.
Objective: To determine diagnostic accuracy of D-dimers levels to diagnose aortic dissection and its different types keeping computed tomographic angiogram as gold standard. Study ...
Aortic Aneurysm
Aortic Aneurysm
Aortic diseases are relatively rare but are associated with high morbidity and mortality. Emergency physicians (EPs) should consider aortic disease in all patients with pain in the...
Aortic Aneurysm
Aortic Aneurysm
Aortic diseases are relatively rare but are associated with high morbidity and mortality. Emergency physicians (EPs) should consider aortic disease in all patients with pain in the...
Aortic dissection in Siriraj patients: Computed tomography findings
Aortic dissection in Siriraj patients: Computed tomography findings
Background: CTA has replaced angiography in both diagnosis and evaluation of aortic dissection. Most findings are associated with true and false lumens which account for the most i...
Decreased expression of fibulin-4 in aortic wall of aortic dissection
Decreased expression of fibulin-4 in aortic wall of aortic dissection
In this research, we will examine the expression of Fibulin-4 in aortic wall to find out its role in aortic dissection development. The samples of aortic wall were obtained from 10...
Abstract 14196: Methamphetamine Use is Associated With Increased In-Hospital Mortality After Aortic Dissection: The National Inpatient Sample Perspective
Abstract 14196: Methamphetamine Use is Associated With Increased In-Hospital Mortality After Aortic Dissection: The National Inpatient Sample Perspective
Introduction:
Aortic dissection is a rare complication associated with methamphetamine abuse. Mortality in aortic dissection is high, however outcomes in methamphetamin...
Clinical Features of Pregnancy-Associated Aortic Dissection and Pregnancy Outcomes
Clinical Features of Pregnancy-Associated Aortic Dissection and Pregnancy Outcomes
Abstract
Background
Pregnancy complicated by aortic dissection is a rare and severe condition. Due to limited clinical experience, there are currently no standardiz...
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Abstract
Background
Although an association between elevated blood pressure and risk of aortic aneurysm is established, f...

