Javascript must be enabled to continue!
Aortic dissection in Siriraj patients: Computed tomography findings
View through CrossRef
Background: CTA has replaced angiography in both diagnosis and evaluation of aortic dissection. Most findings are associated with true and false lumens which account for the most important information in both diagnosis and management.
Objective: To describe computed tomographic (CT) findings including types based on Stanford classification, true and false lumens, acute and chronic aortic dissections, relation to origins of aortic branches, complications and other related findings.
Methods: Computed tomographic angiography (CTA) scans of one hundred and twenty patients with aortic dissection during 2007 to 2016 were retrospectively reviewed. The findings indicating types, true and false lumens, acute and chronic, origination of aortic branches, complication and other related findings are categorized.
Result: Most true lumens were smaller, having outer wall calcification. Most false lumens were larger, showing beak sign, cobweb sign, and intraluminal thrombi. However, the larger lumens could be true lumens as well as the smaller lumen could be a false lumen and outer wall calcification could be seen in a false lumen. The larger true lumens and the smaller false lumens with outer wall calcifications were more often found in chronic aortic dissection than acute aortic dissection. Both acute and chronic aortic dissections were more Stanford type B than type A. Complications included rupture, hemopericardium, hemothorax, hemomediastinum and distal organ infarction, which were more frequent in acute dissection. Intrathoracic complications were more commonly caused by type A acute dissection. Renal infarction was the most common complication in type B acute aortic dissection.
Conclusion: Most CT fi ndings of aortic dissection in this study were typical. Atypical fi ndings were also found in both acute and chronic aortic dissections. Outer wall calcifi cations of false lumens in acute aortic dissection were found in 2 cases.
Foundation for Orphan and Rare Lung Disease (FORLD)
Title: Aortic dissection in Siriraj patients: Computed tomography findings
Description:
Background: CTA has replaced angiography in both diagnosis and evaluation of aortic dissection.
Most findings are associated with true and false lumens which account for the most important information in both diagnosis and management.
Objective: To describe computed tomographic (CT) findings including types based on Stanford classification, true and false lumens, acute and chronic aortic dissections, relation to origins of aortic branches, complications and other related findings.
Methods: Computed tomographic angiography (CTA) scans of one hundred and twenty patients with aortic dissection during 2007 to 2016 were retrospectively reviewed.
The findings indicating types, true and false lumens, acute and chronic, origination of aortic branches, complication and other related findings are categorized.
Result: Most true lumens were smaller, having outer wall calcification.
Most false lumens were larger, showing beak sign, cobweb sign, and intraluminal thrombi.
However, the larger lumens could be true lumens as well as the smaller lumen could be a false lumen and outer wall calcification could be seen in a false lumen.
The larger true lumens and the smaller false lumens with outer wall calcifications were more often found in chronic aortic dissection than acute aortic dissection.
Both acute and chronic aortic dissections were more Stanford type B than type A.
Complications included rupture, hemopericardium, hemothorax, hemomediastinum and distal organ infarction, which were more frequent in acute dissection.
Intrathoracic complications were more commonly caused by type A acute dissection.
Renal infarction was the most common complication in type B acute aortic dissection.
Conclusion: Most CT fi ndings of aortic dissection in this study were typical.
Atypical fi ndings were also found in both acute and chronic aortic dissections.
Outer wall calcifi cations of false lumens in acute aortic dissection were found in 2 cases.
Related Results
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract
Introduction
Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Accuracy of D-Dimers to diagnose aortic dissection and its different types keeping CT angiogram as gold standard.
Accuracy of D-Dimers to diagnose aortic dissection and its different types keeping CT angiogram as gold standard.
Objective: To determine diagnostic accuracy of D-dimers levels to diagnose aortic dissection and its different types keeping computed tomographic angiogram as gold standard. Study ...
Aortic Aneurysm
Aortic Aneurysm
Aortic diseases are relatively rare but are associated with high morbidity and mortality. Emergency physicians (EPs) should consider aortic disease in all patients with pain in the...
Aortic Aneurysm
Aortic Aneurysm
Aortic diseases are relatively rare but are associated with high morbidity and mortality. Emergency physicians (EPs) should consider aortic disease in all patients with pain in the...
Clinical Features of Pregnancy-Associated Aortic Dissection and Pregnancy Outcomes
Clinical Features of Pregnancy-Associated Aortic Dissection and Pregnancy Outcomes
Abstract
Background
Pregnancy complicated by aortic dissection is a rare and severe condition. Due to limited clinical experience, there are currently no standardiz...
Decreased expression of fibulin-4 in aortic wall of aortic dissection
Decreased expression of fibulin-4 in aortic wall of aortic dissection
In this research, we will examine the expression of Fibulin-4 in aortic wall to find out its role in aortic dissection development. The samples of aortic wall were obtained from 10...
Abstract 14196: Methamphetamine Use is Associated With Increased In-Hospital Mortality After Aortic Dissection: The National Inpatient Sample Perspective
Abstract 14196: Methamphetamine Use is Associated With Increased In-Hospital Mortality After Aortic Dissection: The National Inpatient Sample Perspective
Introduction:
Aortic dissection is a rare complication associated with methamphetamine abuse. Mortality in aortic dissection is high, however outcomes in methamphetamin...
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Abstract
Background
Although an association between elevated blood pressure and risk of aortic aneurysm is established, f...

