Dependence of LET on material and its impact on current RBE model

View through CrossRef
Abstract Biological uncertainty remains one of the main sources of uncertainties in proton therapy, and is encapsulated in a scalar quantity known as relative biological effective (RBE). It is currently recognised that a constant RBE of 1.1 is not consistent with radiobiological experiment and may lead to sub-optimal exploitation of the benefits of proton therapy. To overcome this problem, several RBE models have been developed, and in most of these models, there is a dependence of RBE on dose-averaged linear energy transfer (LET), . In this work, we show that the estimation in these models during the data-fitting (or parameter estimation) phase could be subjected to a huge uncertainty due to not taking into account cellular materials during simulation, and this uncertainty can propagate down to the resulting RBE models. The dosimetric impact of this uncertainty is then evaluated on a simple clinical spread out Bragg peak (SOBP) and a prostate example. Our simulation shows that uncertainty due to the use of water as cellular material is non-negligible under low and low dose (2 Gy), and can be neglected otherwise. Thus, this study indicates that further dose and range margins may be required for low target under low dose. This is due to greater uncertainties in RBE model associated with incomplete knowledge of cellular composition for computation.
Title: Dependence of LET on material and its impact on current RBE model
Description:
Abstract Biological uncertainty remains one of the main sources of uncertainties in proton therapy, and is encapsulated in a scalar quantity known as relative biological effective (RBE).
It is currently recognised that a constant RBE of 1.
1 is not consistent with radiobiological experiment and may lead to sub-optimal exploitation of the benefits of proton therapy.
To overcome this problem, several RBE models have been developed, and in most of these models, there is a dependence of RBE on dose-averaged linear energy transfer (LET), .
In this work, we show that the estimation in these models during the data-fitting (or parameter estimation) phase could be subjected to a huge uncertainty due to not taking into account cellular materials during simulation, and this uncertainty can propagate down to the resulting RBE models.
The dosimetric impact of this uncertainty is then evaluated on a simple clinical spread out Bragg peak (SOBP) and a prostate example.
Our simulation shows that uncertainty due to the use of water as cellular material is non-negligible under low and low dose (2 Gy), and can be neglected otherwise.
Thus, this study indicates that further dose and range margins may be required for low target under low dose.
This is due to greater uncertainties in RBE model associated with incomplete knowledge of cellular composition for computation.

Related Results

Impact of variable RBE on proton fractionation
Impact of variable RBE on proton fractionation
Purpose:To explore the impact of variable proton relative biological effectiveness (RBE) on dose fractionation for clinically relevant situations. A generic RBE = 1.1 is generally ...
TH‐F‐105‐05: Comparison of Results for RBE‐Weighted Dose From Two RBE Models for Proton Therapy Treatment Plans
TH‐F‐105‐05: Comparison of Results for RBE‐Weighted Dose From Two RBE Models for Proton Therapy Treatment Plans
Purpose: To evaluate the differences between relative biological effectiveness (RBE)‐weighted doses calculated with either the linear quadratic (LQ) or repair‐misrepair‐fixation (R...
The experimental dose ranges influence the LETd dependency of the proton minimum RBE (RBEmin)
The experimental dose ranges influence the LETd dependency of the proton minimum RBE (RBEmin)
Abstract Cell experiments have shown the proton relative biological effectiveness (RBE) to vary with dose and linear energy transfer (LET), which has led to developm...
Repeatability and Reproducibility of Microdosimetry With a Mini-TEPC
Repeatability and Reproducibility of Microdosimetry With a Mini-TEPC
Experimental microdosimetry measures the energy deposited in a microscopic sensitive volume ( SV ) by single ionizing particles traversing t...
Physical and biological impacts of collimator‐scattered protons in spot‐scanning proton therapy
Physical and biological impacts of collimator‐scattered protons in spot‐scanning proton therapy
AbstractTo improve the penumbra of low‐energy beams used in spot‐scanning proton therapy, various collimation systems have been proposed and used in clinics. In this paper, focused...
Quantifying Radiobiological Variation in Cancer Radiotherapy Using Monte Carlo Simulation and Doped Plastic Scintillators
Quantifying Radiobiological Variation in Cancer Radiotherapy Using Monte Carlo Simulation and Doped Plastic Scintillators
This dissertation examines the extent to which radiobiological variations occur in photon radiotherapy, and then presents a novel methodology and detector prototype to measure this...
Quantifying Radiobiological Variation in Cancer Radiotherapy Using Monte Carlo Simulation and Doped Plastic Scintillators
Quantifying Radiobiological Variation in Cancer Radiotherapy Using Monte Carlo Simulation and Doped Plastic Scintillators
This dissertation examines the extent to which radiobiological variations occur in photon radiotherapy, and then presents a novel methodology and detector prototype to measure this...

Back to Top