Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Biomechanical investigation of the hybrid modified cortical bone screw–pedicle screw fixation technique: Finite-element analysis

View through CrossRef
BackgroundHybrid fixation techniques including the both modified cortical bone trajectory (MCBT) and traditional trajectory (TT) at the L4 and L5 lumbar segment are firstly proposed by our team. Therefore, the purpose of this study is to evaluate and provide specific biomechanical data of the hybrid fixation techniques including the MCBT and TT.MethodsFour human cadaveric specimens were from the anatomy laboratory of Xinjiang Medical University. Four finite-element (FE) models of the L4–L5 lumbar spine were generated. For each of them, four implanted models with the following fixations were established: TT-TT (TT screw at the cranial and caudal level), MCBT-MCBT (MCBT screw at the cranial and caudal level), hybrid MCBT-TT (MCBT screw at the cranial level and TT screw at the caudal level), and TT-MCBT (TT screw at the cranial level and MCBT screw at the caudal level). A 400-N compressive load with 7.5 N/m moments was applied to simulate flexion, extension, lateral bending, and rotation, respectively. The range of motion (ROM) of the L4–L5 segment and the posterior fixation, the von Mises stress of the intervertebral disc, and the posterior fixation were compared.ResultsCompared to the TT-TT group, the MCBT-TT showed a significant lower ROM of the L4–L5 segment (p ≤ 0.009), lower ROM of the posterior fixation (p < 0.001), lower intervertebral disc stress (p < 0.001), and lower posterior fixation stress (p ≤ 0.041). TT-MCBT groups showed a significant lower ROM of the L4–L5 segment (p ≤ 0.012), lower ROM of the posterior fixation (p < 0.001), lower intervertebral disc stress (p < 0.001), and lower posterior fixation stress (p ≤ 0.038).ConclusionsThe biomechanical properties of the hybrid MCBT-TT and TT-MCBT techniques at the L4–L5 segment are superior to that of stability MCBT-MCBT and TT-TT techniques, and feasibility needs further cadaveric study to verify.
Title: Biomechanical investigation of the hybrid modified cortical bone screw–pedicle screw fixation technique: Finite-element analysis
Description:
BackgroundHybrid fixation techniques including the both modified cortical bone trajectory (MCBT) and traditional trajectory (TT) at the L4 and L5 lumbar segment are firstly proposed by our team.
Therefore, the purpose of this study is to evaluate and provide specific biomechanical data of the hybrid fixation techniques including the MCBT and TT.
MethodsFour human cadaveric specimens were from the anatomy laboratory of Xinjiang Medical University.
Four finite-element (FE) models of the L4–L5 lumbar spine were generated.
For each of them, four implanted models with the following fixations were established: TT-TT (TT screw at the cranial and caudal level), MCBT-MCBT (MCBT screw at the cranial and caudal level), hybrid MCBT-TT (MCBT screw at the cranial level and TT screw at the caudal level), and TT-MCBT (TT screw at the cranial level and MCBT screw at the caudal level).
A 400-N compressive load with 7.
5 N/m moments was applied to simulate flexion, extension, lateral bending, and rotation, respectively.
The range of motion (ROM) of the L4–L5 segment and the posterior fixation, the von Mises stress of the intervertebral disc, and the posterior fixation were compared.
ResultsCompared to the TT-TT group, the MCBT-TT showed a significant lower ROM of the L4–L5 segment (p ≤ 0.
009), lower ROM of the posterior fixation (p < 0.
001), lower intervertebral disc stress (p < 0.
001), and lower posterior fixation stress (p ≤ 0.
041).
TT-MCBT groups showed a significant lower ROM of the L4–L5 segment (p ≤ 0.
012), lower ROM of the posterior fixation (p < 0.
001), lower intervertebral disc stress (p < 0.
001), and lower posterior fixation stress (p ≤ 0.
038).
ConclusionsThe biomechanical properties of the hybrid MCBT-TT and TT-MCBT techniques at the L4–L5 segment are superior to that of stability MCBT-MCBT and TT-TT techniques, and feasibility needs further cadaveric study to verify.

Related Results

Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
When used in combination with decompression, spinal fusion is a successful procedure for treating patients with spinal stenosis and degenerative spondylolisthesis. While a number o...
Influence of Different Fixed System in Osteoporotic Lumbar Vertebrae in Fusion:A 3D Finite Element Analysis
Influence of Different Fixed System in Osteoporotic Lumbar Vertebrae in Fusion:A 3D Finite Element Analysis
Abstract Background:Posterior lumbar interbody fusion(PLIF) is the most common surgical method for lumbar fusion surgery, and pedicle screws(PS)can provide effective fixati...
Comparison of posterior open screw fixation with percutaneous fixation among traumatic thoracolumbar fracture patients.
Comparison of posterior open screw fixation with percutaneous fixation among traumatic thoracolumbar fracture patients.
Objectives: To compare outcome and adverse events of open posterior pedicle screw fixation with percutaneous posterior pedicle screw fixation among patients suffering traumatic tho...
Biomechanical characterization of bilateral pedicle screw internal fixation combinations on lumbar vertebrae
Biomechanical characterization of bilateral pedicle screw internal fixation combinations on lumbar vertebrae
Purpose Pedicle screw fixation has been considered a suitable surgical intervention for addressing a diverse range of indications involving the lumbar spinal segments, but the...
Minimizing Pedicle Screw Pullout Risks
Minimizing Pedicle Screw Pullout Risks
Study Design: Detailed biomechanical analysis of the anchorage performance provided by different pedicle screw designs and placement strategies under pullout loading. ...
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
There are no published biomechanical studies evaluating the effect of stabilization techniques on the stability of the 3D printed models of the canine lumbosacral junction. The p...
Biomechanics of Artificial Pedicle Fixation in a 3d-printed Prosthesis After Total en Bloc Spondylectomy: A Finite Element Analysis
Biomechanics of Artificial Pedicle Fixation in a 3d-printed Prosthesis After Total en Bloc Spondylectomy: A Finite Element Analysis
Abstract Background: This study compared the biomechanics of artificial pedicle fixation in spine reconstruction with a 3-dimensional (3D)-printed prosthesis after total en...

Back to Top