Javascript must be enabled to continue!
Optical Interferometric Fringe Pattern-Incorporated Spectrum Calibration Technique for Enhanced Sensitivity of Spectral Domain Optical Coherence Tomography
View through CrossRef
Depth-visualizing sensitivity can be degraded due to imperfect optical alignment and non-equidistant distribution of optical signals in the pixel array, which requires a measurement of the re-sampling process. To enhance this depth-visualizing sensitivity, reference and sample arm-channeled spectra corresponding to different depths using mirrors were obtained to calibrate the spectrum sampling prior to Fourier transformation. During the process, eight interferogram patterns corresponding to point spread function (PSF) signals at eight optical path length differences were acquired. To calibrate the spectrum, generated intensity points of the original interferogram were re-indexed towards a maximum intensity range, and these interferogram re-indexing points were employed to generate a new lookup table. The entire software-based process consists of eight consecutive steps. Experimental results revealed that the proposed method can achieve images with a high depth-visualizing sensitivity. Furthermore, the results validate the proposed method as a rapidly performable spectral calibration technique, and the real-time images acquired using our technique confirm the simplicity and applicability of the method to existing optical coherence tomography (OCT) systems. The sensitivity roll-off prior to the spectral calibration was measured as 28 dB and it was halved after the calibration process.
Title: Optical Interferometric Fringe Pattern-Incorporated Spectrum Calibration Technique for Enhanced Sensitivity of Spectral Domain Optical Coherence Tomography
Description:
Depth-visualizing sensitivity can be degraded due to imperfect optical alignment and non-equidistant distribution of optical signals in the pixel array, which requires a measurement of the re-sampling process.
To enhance this depth-visualizing sensitivity, reference and sample arm-channeled spectra corresponding to different depths using mirrors were obtained to calibrate the spectrum sampling prior to Fourier transformation.
During the process, eight interferogram patterns corresponding to point spread function (PSF) signals at eight optical path length differences were acquired.
To calibrate the spectrum, generated intensity points of the original interferogram were re-indexed towards a maximum intensity range, and these interferogram re-indexing points were employed to generate a new lookup table.
The entire software-based process consists of eight consecutive steps.
Experimental results revealed that the proposed method can achieve images with a high depth-visualizing sensitivity.
Furthermore, the results validate the proposed method as a rapidly performable spectral calibration technique, and the real-time images acquired using our technique confirm the simplicity and applicability of the method to existing optical coherence tomography (OCT) systems.
The sensitivity roll-off prior to the spectral calibration was measured as 28 dB and it was halved after the calibration process.
Related Results
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction
Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
To simplify the cross-calibration process and improve calibration frequency and accuracy, this paper proposes a cross-calibration method for the multispectral remote sensor Multi-S...
Fringe pattern inpainting based on dual-exposure fused fringe guiding CNN denoiser prior
Fringe pattern inpainting based on dual-exposure fused fringe guiding CNN denoiser prior
The intensity of some pixels of the captured fringe will be saturated when fringe projection profilometry is used to measure objects with high reflectivity, which will significantl...
Isolation, characterization and semi-synthesis of natural products dimeric amide alkaloids
Isolation, characterization and semi-synthesis of natural products dimeric amide alkaloids
Isolation, characterization of natural products dimeric amide alkaloids from roots of the Piper chaba Hunter. The synthesis of these products using intermolecular [4+2] cycloaddit...
OPTICAL COHERENCE TOMOGRAPHY-ANGIOGRAPHY, A NEW DIAGNOSTIC AND FOLLOW-UP TOOL FOR GLAUCOMA
OPTICAL COHERENCE TOMOGRAPHY-ANGIOGRAPHY, A NEW DIAGNOSTIC AND FOLLOW-UP TOOL FOR GLAUCOMA
Glaucoma is an optic neuropathy and is one of the leading causes of irreversible blindness worldwide. There are studies on the role of vascular dysfunction in the pathogenesis of g...
Sequence and embryonic expression of three zebrafish fringe genes: lunatic fringe, radical fringe, and manic fringe
Sequence and embryonic expression of three zebrafish fringe genes: lunatic fringe, radical fringe, and manic fringe
AbstractDrosophila fringe and its homologues in vertebrates code for glycosyltransferases that modify Notch, altering the sensitivity of this receptor protein to its ligands Delta ...
Dynamic routing and spectrum allocation in elastic optical networks
Dynamic routing and spectrum allocation in elastic optical networks
Triggered by emerging services such as high-definition video distribution or social networking, the IP traffic volume has been exponentially increasing to date. Furthermore, the tr...
Binocular vision calibration method for a long-wavelength infrared camera and a visible spectrum camera with different resolutions
Binocular vision calibration method for a long-wavelength infrared camera and a visible spectrum camera with different resolutions
We present a calibration plate for the binocular vision system, which is composed of a long-wavelength infrared camera and a visible spectrum camera with different resolutions. The...

