Javascript must be enabled to continue!
Mechanical and biological behaviour of additive manufactured biomimetic biodegradable orthopaedic cortical screws
View through CrossRef
Purpose
The complications caused by metallic orthopaedic bone screws like stress-shielding effect, screw loosening, screw migration, higher density difference, painful reoperation and revision surgery for screw extraction can be overcome with the bioabsorbable bone screws. This study aims to use additive manufacturing (AM) technology to fabricate orthopaedic biodegradable cortical screws to reduce the bone-screw-related-complications.
Design/methodology/approach
The fused filament fabrication technology (FFFT)-based AM technique is used to fabricate orthopaedic cortical screws. The influence of various process parameters like infill pattern, infill percentage, layer height, wall thickness and different biological solutions were observed on the compressive strength and degradation behaviour of cortical screws.
Findings
The porous lattice structures in cortical screws using the rapid prototyping technique were found to be better as porous screws can enhance bone growth and accelerate the osseointegration process with sufficient mechanical strength. The compressive strength and degradation rate of the screw is highly dependent on process parameters used during the fabrication of the screw. The compressive strength of screw is inversely proportional to the degradation rate of the cortical screw.
Research limitations/implications
The present study is focused on cortical screws. Further different orthopaedic screws can be modified with the use of different rapid prototyping techniques.
Originality/value
The use of rapid prototyping techniques for patient-specific bone screw designs is scantly reported. This study uses FFFT-based AM technique to fabricate various infill patterns and porosity of cortical screws to enhance the design of orthopaedic cortical screws.
Title: Mechanical and biological behaviour of additive manufactured biomimetic biodegradable orthopaedic cortical screws
Description:
Purpose
The complications caused by metallic orthopaedic bone screws like stress-shielding effect, screw loosening, screw migration, higher density difference, painful reoperation and revision surgery for screw extraction can be overcome with the bioabsorbable bone screws.
This study aims to use additive manufacturing (AM) technology to fabricate orthopaedic biodegradable cortical screws to reduce the bone-screw-related-complications.
Design/methodology/approach
The fused filament fabrication technology (FFFT)-based AM technique is used to fabricate orthopaedic cortical screws.
The influence of various process parameters like infill pattern, infill percentage, layer height, wall thickness and different biological solutions were observed on the compressive strength and degradation behaviour of cortical screws.
Findings
The porous lattice structures in cortical screws using the rapid prototyping technique were found to be better as porous screws can enhance bone growth and accelerate the osseointegration process with sufficient mechanical strength.
The compressive strength and degradation rate of the screw is highly dependent on process parameters used during the fabrication of the screw.
The compressive strength of screw is inversely proportional to the degradation rate of the cortical screw.
Research limitations/implications
The present study is focused on cortical screws.
Further different orthopaedic screws can be modified with the use of different rapid prototyping techniques.
Originality/value
The use of rapid prototyping techniques for patient-specific bone screw designs is scantly reported.
This study uses FFFT-based AM technique to fabricate various infill patterns and porosity of cortical screws to enhance the design of orthopaedic cortical screws.
Related Results
Design, Manufacturing and Characterization of Biodegradable Bone Screw from PLA Prepared by Fused Deposition Modelling (FDM) 3D Printing Technique
Design, Manufacturing and Characterization of Biodegradable Bone Screw from PLA Prepared by Fused Deposition Modelling (FDM) 3D Printing Technique
Biopolymers are utilized extensively in the medical field. The production of biodegradable bone screws for bone implants utilizing biopolymer materials is one of the advances devel...
Isolation, characterization and semi-synthesis of natural products dimeric amide alkaloids
Isolation, characterization and semi-synthesis of natural products dimeric amide alkaloids
Isolation, characterization of natural products dimeric amide alkaloids from roots of the Piper chaba Hunter. The synthesis of these products using intermolecular [4+2] cycloaddit...
Variables Associated With Loss of Fixation of Retrograde Rami Screws in Minimally Displaced Lateral Compression Type 1 Pelvic Ring Injuries
Variables Associated With Loss of Fixation of Retrograde Rami Screws in Minimally Displaced Lateral Compression Type 1 Pelvic Ring Injuries
OBJECTIVES:
To evaluate variables associated with loss of fixation of retrograde rami screws in the treatment of stress-positive minimally displaced lateral compression...
Representation of women in orthopaedic surgery: perception of barriers among undergraduate medical students in Saudi Arabia
Representation of women in orthopaedic surgery: perception of barriers among undergraduate medical students in Saudi Arabia
Abstract
Background
While female participation has improved in several surgical specialties over time globally, no such increase has been observed i...
Pullout strength of monocortical and bicortical screws in meta -physeal and diaphyseal regions of the canine humerus
Pullout strength of monocortical and bicortical screws in meta -physeal and diaphyseal regions of the canine humerus
Summary
Objective: Monocortical screws are commonly employed in locking plate fixation, but specific recommendations for their placement are lacking and use of short mono...
Pull-out strength of cemented solidversusfenestrated pedicle screws in osteoporotic vertebrae
Pull-out strength of cemented solidversusfenestrated pedicle screws in osteoporotic vertebrae
ObjectivesCement augmentation of pedicle screws could be used to improve screw stability, especially in osteoporotic vertebrae. However, little is known concerning the influence of...
Fixation stability comparison of bone screws based on thread design: buttress thread, triangle thread, and square thread
Fixation stability comparison of bone screws based on thread design: buttress thread, triangle thread, and square thread
Abstract
Background
The influence of thread profile on the fixation stability of bone screws remains unclear. This study aimed to compare the fixati...
Knowledge, Attitudes, and Practice of Biomimetic Dentistry among General Dentists and Specialists in Tripoli, Libya
Knowledge, Attitudes, and Practice of Biomimetic Dentistry among General Dentists and Specialists in Tripoli, Libya
Aim: The aim of this study was to evaluate knowledge, attitudes and Practice of biomimetic dentistry among general dentists and specialists in Tripoli, Libya. Methods: The question...