Javascript must be enabled to continue!
Enhancing C2 pedicle screw placement in Hangman’s fractures: a comparative study of navigation and 3D printed guidance techniques
View through CrossRef
Objective
This retrospective study aimed to analyze the accuracy and safety of pedicle screw placement in upper cervical spine surgery for Hangman's fractures, particularly in cases with high-riding vertebral artery (HRVA) at C2, using navigation technology and 3D-printed patient-specific templates.
Methods
We included 33 patients with Hangman's fractures who underwent posterior cervical fixation with bone graft fusion or non-bone graft fusion surgery between January 2013 and January 2023. Patients were divided into two groups based on the intraoperative pedicle screw placement method: Group A (
n
= 15) utilized a navigation system, and Group B (
n
= 18) used a 3D printed navigation template. Clinical and radiological data were collected and compared.
Results
One hundred and forty-four screws (66 navigated, 78 3D-printed templates) were inserted without vertebral artery, spinal cord, or nerve injury. Operative time per screw: Group A 24.0 ± 5.6 min vs. Group B 18.7 ± 4.1 min; mean difference 5.3 min (22% reduction; 95% CI −9.1 to −1.5;
P
= 0.018). Intra-operative blood loss:152 ± 29 ml vs. 105 ± 19 mL; mean difference 47 mL (95% CI −66 to −19;
P
= 0.001). Overall accuracy (Grade 0 + 1) was 98.5% (65/66) vs. 98.7% (77/78) (odds ratio 1.05; 95% CI 0.11–10.2;
P
= 0.97). In the Type-III fracture subgroup (8 screws per group), templates achieved 100% accuracy vs. 87.5% with navigation (
P
= 0.032) and lower cortical penetration (12.5% vs. 37.5%;
P
= 0.008). Post-operative VAS and NDI improved comparably (all inter-group
P
> 0.05). At 24-month follow-up, all fractures had healed; C2/3 fusion rates did not differ (facet fusion 100% vs. 100%; inter-body fusion 39% vs. 39%;
P
> 0.99).
Conclusion
The use of 3D-printed patient-specific templates in upper cervical spine surgery for Hangman's fractures, especially in the presence of HRVA, is effective and safe. It offers comparable accuracy to navigation-assisted surgery while reducing operative time and blood loss. This approach may be particularly beneficial in minimizing the risk of vertebral artery injury and optimizing surgical outcomes. Compared to navigation technology, it can effectively improve the accuracy of screw placement in extremely unstable fractures.
Frontiers Media SA
Title: Enhancing C2 pedicle screw placement in Hangman’s fractures: a comparative study of navigation and 3D printed guidance techniques
Description:
Objective
This retrospective study aimed to analyze the accuracy and safety of pedicle screw placement in upper cervical spine surgery for Hangman's fractures, particularly in cases with high-riding vertebral artery (HRVA) at C2, using navigation technology and 3D-printed patient-specific templates.
Methods
We included 33 patients with Hangman's fractures who underwent posterior cervical fixation with bone graft fusion or non-bone graft fusion surgery between January 2013 and January 2023.
Patients were divided into two groups based on the intraoperative pedicle screw placement method: Group A (
n
= 15) utilized a navigation system, and Group B (
n
= 18) used a 3D printed navigation template.
Clinical and radiological data were collected and compared.
Results
One hundred and forty-four screws (66 navigated, 78 3D-printed templates) were inserted without vertebral artery, spinal cord, or nerve injury.
Operative time per screw: Group A 24.
0 ± 5.
6 min vs.
Group B 18.
7 ± 4.
1 min; mean difference 5.
3 min (22% reduction; 95% CI −9.
1 to −1.
5;
P
= 0.
018).
Intra-operative blood loss:152 ± 29 ml vs.
105 ± 19 mL; mean difference 47 mL (95% CI −66 to −19;
P
= 0.
001).
Overall accuracy (Grade 0 + 1) was 98.
5% (65/66) vs.
98.
7% (77/78) (odds ratio 1.
05; 95% CI 0.
11–10.
2;
P
= 0.
97).
In the Type-III fracture subgroup (8 screws per group), templates achieved 100% accuracy vs.
87.
5% with navigation (
P
= 0.
032) and lower cortical penetration (12.
5% vs.
37.
5%;
P
= 0.
008).
Post-operative VAS and NDI improved comparably (all inter-group
P
> 0.
05).
At 24-month follow-up, all fractures had healed; C2/3 fusion rates did not differ (facet fusion 100% vs.
100%; inter-body fusion 39% vs.
39%;
P
> 0.
99).
Conclusion
The use of 3D-printed patient-specific templates in upper cervical spine surgery for Hangman's fractures, especially in the presence of HRVA, is effective and safe.
It offers comparable accuracy to navigation-assisted surgery while reducing operative time and blood loss.
This approach may be particularly beneficial in minimizing the risk of vertebral artery injury and optimizing surgical outcomes.
Compared to navigation technology, it can effectively improve the accuracy of screw placement in extremely unstable fractures.
Related Results
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
When used in combination with decompression, spinal fusion is a successful procedure for treating patients with spinal stenosis and degenerative spondylolisthesis. While a number o...
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
There are no published biomechanical studies evaluating the effect of stabilization techniques on the stability of the 3D printed models of the canine lumbosacral junction. The p...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Comparison of posterior open screw fixation with percutaneous fixation among traumatic thoracolumbar fracture patients.
Comparison of posterior open screw fixation with percutaneous fixation among traumatic thoracolumbar fracture patients.
Objectives: To compare outcome and adverse events of open posterior pedicle screw fixation with percutaneous posterior pedicle screw fixation among patients suffering traumatic tho...
Feasibility and improvement of a three-dimensional printed navigation template for modified cortical bone trajectory screw placement in the lumbar spine
Feasibility and improvement of a three-dimensional printed navigation template for modified cortical bone trajectory screw placement in the lumbar spine
ObjectivesCompared with traditional pedicle screw trajectory, cortical bone trajectory (CBT) increases the contact surface between the screw and cortical bone where the screw is su...
Minimizing Pedicle Screw Pullout Risks
Minimizing Pedicle Screw Pullout Risks
Study Design:
Detailed biomechanical analysis of the anchorage performance provided by different pedicle screw designs and placement strategies under pullout loading.
...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference.
Abstract
Fractures are ubiquitous st...