Javascript must be enabled to continue!
Reliability of immersive virtual reality for pre-procedural planning for TAVI: a CT-based validation
View through CrossRef
Abstract
Background
Accurate anatomical assessment is essential for pre-procedural planning in structural heart disease. Advanced 3D imaging could offer improved visualization for more accurate reconstruction. We assessed the performance of a novel immersive 3D virtual reality (VEA) for the
pre-procedural planning of transcatheter aortic valve implantation (TAVI) candidates.
Methods
. Measurement of cardiac-gated contrast-enhanced computed tomography (CT) scans was performed with the novel VEA and established tools: 3Mensio and Horos.
Results
50 consecutive patients were included. Annular and LVOT measurements obtained with VEA were strongly correlated with those derived from standard CT analysis. The intraclass correlation coefficient (ICC) confirmed excellent consistency for annular measurements (ICC=0.93), while the concordance correlation coefficient indicated very good overall agreement (CCC=0.83, 95%CI 0.73–0.90) (Figure, left panel). Similarly, LVOT measurements obtained with VEA showed strong correlation with CT values, with good consistency (ICC=0.90), and good overall agreement (CCC =0.77, 95% CI 0.64–0.86) (Figure, right panel). VEA–based planning improved prosthesis size selection accuracy, achieving higher concordance with implanted valves and a significant net reclassification gain over conventional CT.
Conclusions
Given the increasing use of advanced 3D cardiac imaging technologies, understanding their diagnostic accuracy to guide preprocedural planning of TAVI is paramount. In our study, VEA provided reliable assessment of aortic root anatomy for TAVI planning. This novel 3D software provides accurate, patient-specific reconstructions of the aortic root and surrounding structures, that may optimize valve sizing, improve procedural safety and enhance procedural outcomes. This provides a rational for future studies to assess the procedural benefit derived from a three-dimensional assessment of the aortic valve geometry.FigureFor image description, please refer to the figure legend and surrounding text.
Oxford University Press (OUP)
Title: Reliability of immersive virtual reality for pre-procedural planning for TAVI: a CT-based validation
Description:
Abstract
Background
Accurate anatomical assessment is essential for pre-procedural planning in structural heart disease.
Advanced 3D imaging could offer improved visualization for more accurate reconstruction.
We assessed the performance of a novel immersive 3D virtual reality (VEA) for the
pre-procedural planning of transcatheter aortic valve implantation (TAVI) candidates.
Methods
.
Measurement of cardiac-gated contrast-enhanced computed tomography (CT) scans was performed with the novel VEA and established tools: 3Mensio and Horos.
Results
50 consecutive patients were included.
Annular and LVOT measurements obtained with VEA were strongly correlated with those derived from standard CT analysis.
The intraclass correlation coefficient (ICC) confirmed excellent consistency for annular measurements (ICC=0.
93), while the concordance correlation coefficient indicated very good overall agreement (CCC=0.
83, 95%CI 0.
73–0.
90) (Figure, left panel).
Similarly, LVOT measurements obtained with VEA showed strong correlation with CT values, with good consistency (ICC=0.
90), and good overall agreement (CCC =0.
77, 95% CI 0.
64–0.
86) (Figure, right panel).
VEA–based planning improved prosthesis size selection accuracy, achieving higher concordance with implanted valves and a significant net reclassification gain over conventional CT.
Conclusions
Given the increasing use of advanced 3D cardiac imaging technologies, understanding their diagnostic accuracy to guide preprocedural planning of TAVI is paramount.
In our study, VEA provided reliable assessment of aortic root anatomy for TAVI planning.
This novel 3D software provides accurate, patient-specific reconstructions of the aortic root and surrounding structures, that may optimize valve sizing, improve procedural safety and enhance procedural outcomes.
This provides a rational for future studies to assess the procedural benefit derived from a three-dimensional assessment of the aortic valve geometry.
FigureFor image description, please refer to the figure legend and surrounding text.
Related Results
Transcatheter aortic valve implantation in degenerated trans-catheter and surgical bioprosthetic aortic valve
Transcatheter aortic valve implantation in degenerated trans-catheter and surgical bioprosthetic aortic valve
Abstract
Background
The moving forward indication of transcatheter aortic valve implantation (TAVI) to younger aortic valve sten...
E-071 Organization of a Neurointerventional Fellowship Curriculum
E-071 Organization of a Neurointerventional Fellowship Curriculum
Introduction
The field of Neurointervention has attracted some of the very best physicians across the world. Given the interdisciplinary nature of this specialty,...
Prognostic impact of postprocedure stroke volume in patients with low-gradient aortic stenosis
Prognostic impact of postprocedure stroke volume in patients with low-gradient aortic stenosis
Objective
The effect of postoperative blood flow status on the prognosis of patients with low-gradient severe aortic stenosis (AS) has not been examined. Severe A...
not-yet-known not-yet-known not-yet-known unknown ”Decoding the H-V Interval: Unraveling Its Reliability as a Pacemaker Indicator Post-TAVI”
not-yet-known not-yet-known not-yet-known unknown ”Decoding the H-V Interval: Unraveling Its Reliability as a Pacemaker Indicator Post-TAVI”
not-yet-known
not-yet-known
not-yet-known
unknown
Introduction: Transcatheter aortic valve implantation (TAVI) is
...
Predisposing and precipitating factors of post-operative delirium after transfemoral TAVI
Predisposing and precipitating factors of post-operative delirium after transfemoral TAVI
Abstract
Background
Transcatheter aortic valve implantation (TAVI) represents the treatment of choice for aortic stenosis (AS) p...
Ultra-low dose contrast CT-angiography in TAVI candidates with severe renal failure
Ultra-low dose contrast CT-angiography in TAVI candidates with severe renal failure
Abstract
Introduction
computer tomography angiography (CTA) has assumed an important role in patient screening before TAVI. The ...
Feasibility of ultra-low volume contrast pulmonary arterial injection protocol for CTA in TAVI candidates with severe renal failure
Feasibility of ultra-low volume contrast pulmonary arterial injection protocol for CTA in TAVI candidates with severe renal failure
Abstract
Introduction
Computer tomography angiography (CTA) has an important role in patient screening before TAVI. The high vol...
Predictors of futility outcomes after TAVI: insights from the France TAVI Registry
Predictors of futility outcomes after TAVI: insights from the France TAVI Registry
Abstract
Background
Transcatheter aortic valve implantation (TAVI) has revolutionized the treatment of aortic stenosis and provi...

