Javascript must be enabled to continue!
Prognostic impact of postprocedure stroke volume in patients with low-gradient aortic stenosis
View through CrossRef
Objective
The effect of postoperative blood flow status on the prognosis of patients with low-gradient severe aortic stenosis (AS) has not been examined. Severe AS is associated with a higher mortality rate after transcatheter aortic valve implantation (TAVI). We examined the prognostic value of low-flow status by comparing stroke volume indices (SVi) before and after TAVI in patients with symptomatic, low-gradient severe AS.
Methods
A total of 1613 patients with severe symptomatic AS who underwent TAVI in 14 Japanese institutes for low-gradient severe AS (418 patients, median age 84 years, 32.5% men) were prospectively enrolled. The primary endpoint was cardiovascular mortality during follow-up after TAVI, and independent predictors were evaluated. Receiver operating characteristic curves were generated to determine the optimal cut-off value of post-TAVI SVi for predicting cardiovascular mortality, and the receiver operating characteristic curves of pre-TAVI and post-TAVI SVi were compared.
Results
The cardiovascular mortality rate was 4.1% (17 patients) during follow-up (median 9.2 months). Multivariate analysis revealed post-TAVI SVi to be an independent predictor of cardiovascular mortality (per 10 mL/m2 decrease; HR, 2.0; 95% CI 1.28 to 3.12). The optimal cut-off value of post-TAVI SVi was 41.4 mL/m2. Post-TAVI SVi showed significantly larger area under the curve than pre-TAVI SVi (0.74 (95% CI 0.69 to 0.79) vs 0.61 (95% CI 0.56 to 0.65), p<0.05).
Conclusions
Post-TAVI SVi is a better predictor of cardiovascular mortality than pre-TAVI SVi in patients with symptomatic low-gradient severe AS. Low-flow and low-normal-flow status (35≤ SVi <40 mL/m2) require careful management after TAVI.
BMJ
Yugo Nara
Akihisa Kataoka
Yusuke Watanabe
Nakashima Makoto
Hirofumi Hioki
Hideyuki Kawashima
Nagura Fukuko
Ken Kozuma
Shinichi Shirai
Norio Tada
Motoharu Araki
Toru Naganuma
Futoshi Yamanaka
Hiroshi Ueno
Minoru Tabata
Kazuki Mizutani
Akihiro Higashimori
Kensuke Takagi
Masanori Yamamoto
Kentaro Hayashida
Title: Prognostic impact of postprocedure stroke volume in patients with low-gradient aortic stenosis
Description:
Objective
The effect of postoperative blood flow status on the prognosis of patients with low-gradient severe aortic stenosis (AS) has not been examined.
Severe AS is associated with a higher mortality rate after transcatheter aortic valve implantation (TAVI).
We examined the prognostic value of low-flow status by comparing stroke volume indices (SVi) before and after TAVI in patients with symptomatic, low-gradient severe AS.
Methods
A total of 1613 patients with severe symptomatic AS who underwent TAVI in 14 Japanese institutes for low-gradient severe AS (418 patients, median age 84 years, 32.
5% men) were prospectively enrolled.
The primary endpoint was cardiovascular mortality during follow-up after TAVI, and independent predictors were evaluated.
Receiver operating characteristic curves were generated to determine the optimal cut-off value of post-TAVI SVi for predicting cardiovascular mortality, and the receiver operating characteristic curves of pre-TAVI and post-TAVI SVi were compared.
Results
The cardiovascular mortality rate was 4.
1% (17 patients) during follow-up (median 9.
2 months).
Multivariate analysis revealed post-TAVI SVi to be an independent predictor of cardiovascular mortality (per 10 mL/m2 decrease; HR, 2.
0; 95% CI 1.
28 to 3.
12).
The optimal cut-off value of post-TAVI SVi was 41.
4 mL/m2.
Post-TAVI SVi showed significantly larger area under the curve than pre-TAVI SVi (0.
74 (95% CI 0.
69 to 0.
79) vs 0.
61 (95% CI 0.
56 to 0.
65), p<0.
05).
Conclusions
Post-TAVI SVi is a better predictor of cardiovascular mortality than pre-TAVI SVi in patients with symptomatic low-gradient severe AS.
Low-flow and low-normal-flow status (35≤ SVi <40 mL/m2) require careful management after TAVI.
Related Results
Iranian stroke model-how to involve health policymakers
Iranian stroke model-how to involve health policymakers
Stroke in Iran, with more than 83 million population, is a leading cause of disability and mortality in adults. Stroke has higher incidence in Iran comparing the global situation a...
Critical Arterial Stenosis Revisited
Critical Arterial Stenosis Revisited
Abstract
Introduction
Stenosis of an organ/tissue primary artery can produce ischemia or only reduce blood flow reserve. Despit...
HIPERTENSI, USIA, JENIS KELAMIN DAN KEJADIAN STROKE DI RUANG RAWAT INAP STROKE RSUD dr. M. YUNUS BENGKULU
HIPERTENSI, USIA, JENIS KELAMIN DAN KEJADIAN STROKE DI RUANG RAWAT INAP STROKE RSUD dr. M. YUNUS BENGKULU
Hypertension, Age, Sex, and Stroke Incidence In Stroke Installation Room RSUD dr. M. Yunus BengkuluABSTRAKStroke adalah gejala-gejala defisit fungsi susunan saraf yang diakibatka...
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Abstract
Background
Although an association between elevated blood pressure and risk of aortic aneurysm is established, f...
Acquired Supravalvular Aortic Stenosis: Review of a Rare Conundrum with Diverse Etiologies
Acquired Supravalvular Aortic Stenosis: Review of a Rare Conundrum with Diverse Etiologies
Background
Supravalvular aortic stenosis is a rare form of left ventricular outflow tract obstruction. Classically, supravalvular aortic stenosis occurs seconda...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract
Introduction
Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Abstract Number ‐ 248: Association Between Vertebrobasilar Stenosis, Location, and Quantitative Magnetic Resonance Angiography Flow State
Abstract Number ‐ 248: Association Between Vertebrobasilar Stenosis, Location, and Quantitative Magnetic Resonance Angiography Flow State
Introduction
The relationship between the degree of vertebrobasilar stenosis and QMRA distal‐flow status is uncertain. Our aim was to investigate this relationship.
...
Prevalence of Patients With Severe Aortic Stenosis, Low Flow And Preserved Ejection Fraction: Results From a Cath-Lab Data Base.
Prevalence of Patients With Severe Aortic Stenosis, Low Flow And Preserved Ejection Fraction: Results From a Cath-Lab Data Base.
Abstract
Recent echocardiographic studies described that almost 30% of patients with severe aortic valve stenosis on the basis of aortic valve area may paradoxica...

