Javascript must be enabled to continue!
A Comparison of Efficacy, Safety and Cost Between MANTATM and Proglide Vascular Closure Devices Following Transfemoral Transcatheter Aortic Valve Implantation
View through CrossRef
Aims Access site vascular complications remain a recognised complication following transcatheter aortic valve implantation (TAVI). Suture-based vascular closure devices (VCDs) such as ProGlide® (Abbott Vascular Inc., Santa Clara, CA, USA) are widely used in order to achieve rapid haemostasis. The MANTATM (Essential Medical Inc., Malvern, PA, USA) is a collagen plug-based VCD which can be used as an alternative to traditional suture-based devices, but is significantly more expensive per-unit. We compare the efficacy, safety and total cost associated with the use of the MANTATM and ProGlide® VCDs. Methods This retrospective study included all consecutive patients who underwent transfemoral (TF) TAVI between November 2017-June 2018. The primary endpoints were primary access site-related VARC-2 vascular complications, VARC-2 bleeding and the overall per-patient cost incorporating treatment for complications or use of additional VCDs. Results A total of 136 patients were included in this study; 86 in the ProGlide® group and 50 in the MANTATM group. Baseline characteristics of the two groups were well-matched. Three patients in the ProGlide® group required surgical repair compared to none in the MANTATM group. However, no significant differences were observed with respect to overall primary access site-related VARC-2 vascular complications (10.5% vs. 10%; p=0.93) or VARC-2 bleeding (9.3% vs. 4.0%; p=0.25). There was no significant difference in the mean cost per patient when taking into consideration the use of additional VCDs and treatments for vascular complications (£568.79 vs. £599.95; p=0.90). Conclusion The use of the MANTATM VCD following TF TAVI is cost-neutral compared to ProGlide® VCDs, whilst being associated with no increase in VARC-2 vascular or bleeding complications.
Title: A Comparison of Efficacy, Safety and Cost Between MANTATM and Proglide Vascular Closure Devices Following Transfemoral Transcatheter Aortic Valve Implantation
Description:
Aims Access site vascular complications remain a recognised complication following transcatheter aortic valve implantation (TAVI).
Suture-based vascular closure devices (VCDs) such as ProGlide® (Abbott Vascular Inc.
, Santa Clara, CA, USA) are widely used in order to achieve rapid haemostasis.
The MANTATM (Essential Medical Inc.
, Malvern, PA, USA) is a collagen plug-based VCD which can be used as an alternative to traditional suture-based devices, but is significantly more expensive per-unit.
We compare the efficacy, safety and total cost associated with the use of the MANTATM and ProGlide® VCDs.
Methods This retrospective study included all consecutive patients who underwent transfemoral (TF) TAVI between November 2017-June 2018.
The primary endpoints were primary access site-related VARC-2 vascular complications, VARC-2 bleeding and the overall per-patient cost incorporating treatment for complications or use of additional VCDs.
Results A total of 136 patients were included in this study; 86 in the ProGlide® group and 50 in the MANTATM group.
Baseline characteristics of the two groups were well-matched.
Three patients in the ProGlide® group required surgical repair compared to none in the MANTATM group.
However, no significant differences were observed with respect to overall primary access site-related VARC-2 vascular complications (10.
5% vs.
10%; p=0.
93) or VARC-2 bleeding (9.
3% vs.
4.
0%; p=0.
25).
There was no significant difference in the mean cost per patient when taking into consideration the use of additional VCDs and treatments for vascular complications (£568.
79 vs.
£599.
95; p=0.
90).
Conclusion The use of the MANTATM VCD following TF TAVI is cost-neutral compared to ProGlide® VCDs, whilst being associated with no increase in VARC-2 vascular or bleeding complications.
Related Results
Vascular closure devices in TAVI: MANTA versus ProGlide in a propensity-matched population
Vascular closure devices in TAVI: MANTA versus ProGlide in a propensity-matched population
Abstract
Background
Vascular complications increase morbidity and mortality in transcatheter aortic valve implantation (TAVI). A...
Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Transcatheter aortic valve replacement is a well-established treatment for high-surgical-risk patients with severe aortic disease, providing a less invasive alternative to traditio...
Safety and effectiveness of single ProStyle™/ProGlide™ for aortic endovascular procedures: single-style study
Safety and effectiveness of single ProStyle™/ProGlide™ for aortic endovascular procedures: single-style study
BackgroundThe Perclose ProStyle™/ProGlide™ Suture-Mediated Closure and Repair (SMCR) System is designed to close the common femoral artery (CFA) access during percutaneous endovasc...
Incidence, predictors and outcomes of Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR): a systematic review and meta-analysis
Incidence, predictors and outcomes of Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR): a systematic review and meta-analysis
Abstract
Background
Surgical aortic valve replacement has been the treatment of choice for patients with aortic valve disease be...
Abstract 13177: The Association Between Insufficient Valve Expansion and Aortic Valve Calcification for Transcatheter Valve Implantation With Self-Expandable Valve
Abstract 13177: The Association Between Insufficient Valve Expansion and Aortic Valve Calcification for Transcatheter Valve Implantation With Self-Expandable Valve
Background:
Transcatheter aortic valve implantation (TAVI) has emerged as the preferred treatment for severe aortic stenosis. Nevertheless, severe calcification remains...
Short and long-term complications of transcatheter aortic valve replacement: a systematic review and meta-analysis
Short and long-term complications of transcatheter aortic valve replacement: a systematic review and meta-analysis
Abstract
Background
Transcatheter aortic valve replacement (TAVR) is superior or non-inferior to surgical aortic valve re...
The Critical Role of Presettable and Expandable Artificial Surgical Valves in the Lifetime Management of Valvular Heart Disease
The Critical Role of Presettable and Expandable Artificial Surgical Valves in the Lifetime Management of Valvular Heart Disease
With the trend of younger patients undergoing surgical valve replacement and increased life expectancy, how to account for subsequent therapies during the initial valve replacement...
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
Objectives
To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia.
...

