Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Improving outcomes in single chamber leadless pacemakers: strategies for minimizing vascular complications

View through CrossRef
Abstract Background Leadless pacemaker therapy is associated with a significant reduction in lead-related complication rate compared to conventional transvenous single chamber pacemaker therapy. However, a significant complication rate of 1.2% was observed in vascular access due to the use of large delivery femoral sheath (27Fr). The aim of this study was to evaluate the effectiveness of real-time ultrasound guidance and Z suture technique in reducing total and major vascular complications in leadless pacemaker therapy. Method In this study, we performed a retrospective and prospective analysis of all adverse events associated with leadless pacemaker (Micra) implantation by two operators at a single tertiary center from December 2016 to December 2018. To mitigate the risk of vascular complications, all patients underwent real-time ultrasound-guided venipuncture for vascular access, as well as the application of a Z-suture technique for hemostasis at the end of the procedure. Data were collected on implant indications, implant procedure details, complications, and follow-up information. Results In this study, 45 patients with an age range of 24 to 94 years (mean 76 ± 14 years) were recruited, with 21 (46.6%) being female. The pacing indications for the patients included atrial fibrillation (24, 53.3%), vascular (7, 15.5%), infection (9, 20%), cognitive/frailty (3, 6.6%), and occupational (2, 4.4%). The implant procedures were performed under general anesthesia in 6 (13.3%) of the cases, and under local anesthesia and sedation in 39 (86.6%) of the cases. A single deployment was achieved in 43 (95.5%) of the patients, while 2 deployments were required in 2 (4.4%) of the patients. Notably, no vascular or major complications were reported in our cohort of patients. Conclusions The results of this observational study indicate that incorporating real-time ultrasound guidance during venipuncture and the use of a Z-suture technique significantly reduce the occurrence of both total and major vascular complications associated with the implantation of leadless pacemaker. However, more robust and larger studies are required in order to confirm these results and implications for clinical practice.
Title: Improving outcomes in single chamber leadless pacemakers: strategies for minimizing vascular complications
Description:
Abstract Background Leadless pacemaker therapy is associated with a significant reduction in lead-related complication rate compared to conventional transvenous single chamber pacemaker therapy.
However, a significant complication rate of 1.
2% was observed in vascular access due to the use of large delivery femoral sheath (27Fr).
The aim of this study was to evaluate the effectiveness of real-time ultrasound guidance and Z suture technique in reducing total and major vascular complications in leadless pacemaker therapy.
Method In this study, we performed a retrospective and prospective analysis of all adverse events associated with leadless pacemaker (Micra) implantation by two operators at a single tertiary center from December 2016 to December 2018.
To mitigate the risk of vascular complications, all patients underwent real-time ultrasound-guided venipuncture for vascular access, as well as the application of a Z-suture technique for hemostasis at the end of the procedure.
Data were collected on implant indications, implant procedure details, complications, and follow-up information.
Results In this study, 45 patients with an age range of 24 to 94 years (mean 76 ± 14 years) were recruited, with 21 (46.
6%) being female.
The pacing indications for the patients included atrial fibrillation (24, 53.
3%), vascular (7, 15.
5%), infection (9, 20%), cognitive/frailty (3, 6.
6%), and occupational (2, 4.
4%).
The implant procedures were performed under general anesthesia in 6 (13.
3%) of the cases, and under local anesthesia and sedation in 39 (86.
6%) of the cases.
A single deployment was achieved in 43 (95.
5%) of the patients, while 2 deployments were required in 2 (4.
4%) of the patients.
Notably, no vascular or major complications were reported in our cohort of patients.
Conclusions The results of this observational study indicate that incorporating real-time ultrasound guidance during venipuncture and the use of a Z-suture technique significantly reduce the occurrence of both total and major vascular complications associated with the implantation of leadless pacemaker.
However, more robust and larger studies are required in order to confirm these results and implications for clinical practice.

Related Results

Abstract 4367732: Leadless Pacemaker Implantation in the Region of Bachmann’s Bundle: Initial Results
Abstract 4367732: Leadless Pacemaker Implantation in the Region of Bachmann’s Bundle: Initial Results
Background: Leadless pacemakers are an emerging technology offering a less invasive alternative to traditional transvenous systems. Bachmann bundle (BB) pacing ...
Leadless Pacemaker tine fracture and dislocation: two case reports
Leadless Pacemaker tine fracture and dislocation: two case reports
Abstract The rate of leadless pacemaker implantation is increasing worldwide. To date, there have been few reports of leadless pacemaker dislocation and extraction. This ar...
P185 FOLLOW–UP OF PATIENTS UNDERGOING POST–EXTRACTION LEADLESS PACEMAKER IMPLANTATION
P185 FOLLOW–UP OF PATIENTS UNDERGOING POST–EXTRACTION LEADLESS PACEMAKER IMPLANTATION
Abstract Introduction The implantation of traditional stimulation devices involves numerous complications, in the short and long...
Aveir Leadless Pacemaker implantation in pediatric population: a case series
Aveir Leadless Pacemaker implantation in pediatric population: a case series
Abstract Background While the Medtronic Micra pacemaker provided a small device for leadless pacemaker implantation, the Aveir d...
Electrophysiology and Indications for Pacing in the ‘8O’s*
Electrophysiology and Indications for Pacing in the ‘8O’s*
Bradycardias originate either from a dysfunction of impulse formation in the sinoatrial node or from a disturbed conduction of the impulse. Different pathogenetic mechanisms are di...
Pacemaker complications in the Early Period Post implantation (Preprint)
Pacemaker complications in the Early Period Post implantation (Preprint)
BACKGROUND Background: Over the past few years, cardiac pacemaker technology has advanced significantly, moving from basic single-chamber devices to complex...
Bacteraemia after leadless pacemaker implantation
Bacteraemia after leadless pacemaker implantation
Background: Transvenous permanent pacemaker related infection is a severe condition associated with significant morbidity and mortality. Leadless pacemakers may be more resistant t...
Inductive Power Transfer Link at 13.56 MHz for Leadless Cardiac Pacemakers
Inductive Power Transfer Link at 13.56 MHz for Leadless Cardiac Pacemakers
Inductive power links are most viable for the long-term powering of cardiac pacemakers. Designing an inductive power link without surpassing the specific absorption rate (SAR) for ...

Back to Top